A hookes law calculator (Hooke’s law, F = kx) finds the force, the spring rate or the deflection of a spring from the other two, and the energy stored. The same page also gives the rate of a coil spring from its wire, the rate of springs in series or parallel, and converts a spring rate between units.
How to use the hookes law calculator
- Choose what to find: force, rate, deflection, a coil spring rate, series, parallel or a unit conversion.
- Enter the values that the page asks for, in US or metric units.
- Press Calculate.
Hooke’s law
The page states Hooke’s law for a spring as F = −kx, where x is the displacement from the rest length, F is the restoring force and k is the rate, also called the spring constant or force constant [1]. The minus sign says that the force opposes the displacement [1]. The calculator works with the size of the force, F = kx, which is the magnitude form of the law [1].
Units of the spring rate
The rate is force per unit of length. The Wikipedia page gives the unit as newtons per metre, which is also kg/s² [1]. The Spring page also gives the rate of a spring as force per unit of deflection [2], so lbf/in is a natural US unit. In US mode the tool takes pounds-force and inches, with the rate in lbf/in. In metric mode it takes newtons and millimetres, with the rate in N/mm. Each result also shows the SI value in N/m, and the conversion tab shows lbf/ft too.
Force, rate and deflection
Pick the quantity that you want. The force is F = kx, the rate is k = F ÷ x and the deflection is x = F ÷ k [1]. For example, a rate of 80 N/m and a displacement of 0.15 m give a force of 12 N. In the metric mode, enter the rate as 0.08 N/mm and the deflection as 150 mm to get the same 12 N.
Energy stored in a spring
The Wikipedia page gives the elastic potential energy of a spring as U = ½kx², which comes from adding up the force over the deflection [1]. In the same form, U = F²÷(2k). The calculator shows this energy with every result. A rate of 2 N/mm compressed by 30 mm needs 60 N and stores 0.9 J.
Rate of a coil spring
For a round-wire helical spring, the wire twists as the spring is loaded, which gives the rate G d⁴ ÷ (8 D³ n) [3], where G is the shear modulus, d the wire diameter, D the mean coil diameter (the outer diameter minus d) and n the number of active coils. A wire of 2 mm in a coil of 20 mm mean diameter with 8 active coils and G = 79 GPa gives 2.4688 N/mm. The 79 GPa is only an example: look up the modulus for your wire.
Counting the active coils
Only the active coils count, not the dead ones at the ends. As a common rule of thumb, closed and squared or ground ends have two inactive coils, double closed ends have four, and open ends have none; check the maker's data for your spring. Subtract these from the total number of coils before entering n. This matters, because the rate is inversely proportional to n, so one miscounted coil on a short spring changes the rate by a large share.
Springs in parallel
When springs share the load side by side, the standard rule is that the rates add [2]. Two springs of 2 and 3 N/mm in parallel give 5 N/mm, and a set of 2, 3 and 6 N/mm gives 11 N/mm. The combination is stiffer than any single spring. The sum is k = k₁ + k₂ + …. Enter the rates separated by commas.
Springs in series
When springs are connected end to end, the standard rule is that the compliance, which is the inverse of the rate, adds [2]. So 1 ÷ k = 1 ÷ k₁ + 1 ÷ k₂ + …. The set of 2, 3 and 6 N/mm gives exactly 1 N/mm, which is softer than the softest spring. Two equal springs in series have half the rate of one. Series is how you make a long, soft suspension from short springs.
Converting a spring rate
Select the conversion job, enter a rate, and the page lists it in N/m, N/mm, lbf/in and lbf/ft. For example, 10 N/m over 0.5 m gives 5 N, which is 1.124 lbf. The tool uses 4.4482216152605 newtons per pound-force and 0.0254 metres per inch; these two standard factors are our own addition. A rate of 1 N/mm is 5.7101 lbf/in.
The limits of the model
The Spring page says that a real spring follows Hooke’s law only approximately, and only below its elastic limit [2]. Beyond that, it stays bent or the force is no longer proportional to the deflection. The coil formula also assumes a round wire and uniform coils. Use the results for a first sizing, and check the solid height, the maximum stress and the maker’s data. Do not push a spring past the load that the maker states.
Common mistakes
- Mixing the units of the rate and the deflection. Check that you use lbf/in with inches or N/mm with millimetres.
- Using the outer diameter as the mean one. Choose the diameter type, or subtract the wire diameter.
- Counting dead coils as active. Use only the active coils in the coil formula.
- Adding the rates of springs in series. In series the inverse rates add.
What next
Use this often? Add Hookes Law to your Home screen.
Frequently asked questions
What is a Hookes law calculator?
It solves F = kx for the force, the spring rate or the deflection of a spring and shows the energy stored in it.
How do I find the spring rate of a coil spring?
Choose the coil spring job and enter the shear modulus, wire diameter, coil diameter and number of active coils; the rate is G d to the fourth power divided by 8 D cubed n.
How do springs in series and in parallel combine?
In parallel the rates add; in series the inverse rates (the compliances) add.
What units can the spring rate have?
Newtons per metre, newtons per millimetre, pounds-force per inch or per foot; the calculator converts between them.
When does Hooke’s law stop working?
Above the elastic limit of the spring, where the force is no longer proportional to the deflection.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.