Wastewater Calculator

Use this wastewater calculator to find the F/M ratio, hydraulic retention time, mean cell residence time, sludge age or sludge volume index of an activated sludge plant.

Restored your last values ·

mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mL/L

Choose US or metric units and the measure you want: F/M, hydraulic retention time, mean cell residence time, sludge age or sludge volume index. Fill in the boxes that appear for that measure. Concentrations are in mg/L.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose what to find, fill in the boxes that appear and press Calculate.

See full result

A wastewater calculator works out the common control measures of an activated sludge plant. Choose one of five: the food to microorganism ratio, the hydraulic retention time, the mean cell residence time, the sludge age or the sludge volume index, and enter the plant data that it needs.

How to use the wastewater calculator

  1. Choose US or metric units and the measure to find.
  2. Fill in the boxes that appear for that measure.
  3. Press Calculate and read the result and the working.

The plant model

An activated sludge plant is checked with a handful of control measures. Wikipedia describes the F/M ratio, the mean cell residence time and the sludge volume index, and the use of COD in place of BOD [1]. This tool covers five measures in one place, since BOD and COD are inputs here. Every example below is our own, and where a formula is our own working we say so.

Food to microorganism ratio

F/M is the ratio of the food fed each day to the mass of microorganisms [1]. We take the food as the BOD loading, the influent BOD times the flow, and the microorganisms as the MLVSS mass in the aeration tank. With 200 mg/L, 5 MGD, 1.5 MG and 2,000 mg/L, the loading is 8,340 pounds per day, the MLVSS is 25,020 pounds and F/M is 0.3333 per day.

Hydraulic retention time

HRT is the tank volume divided by the flow, with both in the same volume unit. Wikipedia defines the mean residence time of a liquid as the amount contained divided by the flow rate through it, and calls it the hydraulic retention time [2]. For example, a tank of 3,000 cubic metres with a flow of 10,000 cubic metres a day gives 0.3 days, or 7.2 hours. The calculator also shows the hours. With 1.5 MG and 5 MGD you get the same 0.3 days. A shorter time means that the water passes through faster.

Mean cell residence time

MCRT is the mass of solids in the aeration tank and the secondary clarifiers divided by the mass leaving each day [1]. We take the solids leaving as the effluent flow times its solids plus the waste sludge flow times its solids, which is our reconstruction. With 2,500 mg/L, 1.5 MG plus 0.5 MG, 4.9 MGD at 15 mg/L and 0.1 MGD at 8,000 mg/L, it is 41,700 pounds over 7,285 pounds a day: 5.724 days.

Sludge age

Sludge age is the solids in the aeration tank divided by the suspended solids entering it each day. This is our own definition, since Wikipedia gives no separate definition of sludge age. With 2,500 mg/L in 1.5 MG, and 100 mg/L at 5 MGD, the tank holds 31,275 pounds and 4,170 pounds a day enter, so the age is 7.5 days. It differs from the MCRT, which counts the clarifiers and the solids that leave.

Sludge volume index

SVI is the settled sludge volume after 30 minutes, in millilitres per litre, divided by the MLSS in grams per litre [3]. It is the volume in millilitres taken up by one gram of sludge, so the unit is millilitres per gram. With 250 mL/L and 2,500 mg/L, the SVI is 100 mL/g. As reference bands the tool uses our own planning figures: 80 or less is very dense, 100 to 200 is desirable and 250 or more is very slow settling. Wikipedia gives no cut-off values [3], so check your plant's own targets. A 120 mL/L settled volume gives 48.

The 8.34 factor

In US units, a concentration in mg/L times a volume in million gallons gives pounds when multiplied by 8.34, the approximate weight in pounds of a US gallon of water, which is our own note. In metric mode, a concentration in mg/L times a volume in cubic metres gives grams, so we multiply by 0.001 to show kilograms. In the ratios, such as F/M, MCRT and sludge age, this factor appears on top and bottom and cancels, which is our own observation, so the ratios are the same in both unit systems.

BOD or COD

Wikipedia says that the chemical oxygen demand is generally used in place of the biochemical oxygen demand, since BOD takes five days to give a result [1]. If you have a COD figure, you can enter it in the BOD box, and the F/M ratio will be based on COD. Be consistent: compare it only with targets that use the same measure.

Units

In US mode the volumes are in million gallons and the flows in million gallons a day. In metric mode they are in cubic metres and cubic metres a day. The concentrations are in mg/L in both. The volume and the flow must use the same volume unit for the HRT to be in days. The loadings are shown in pounds or kilograms per day.

Limits

This is a simple operations check. It does not size a plant, check an effluent permit or replace laboratory methods, and an activated sludge plant has many other controls. Samples vary during the day, so use averages. When a result looks odd, check the units first, then the sampling.

Reading the results together

A single value says little by itself. Work out the measures from the same set of samples and keep them in a log, so that you can see how F/M, sludge age and SVI move from week to week. Compare each one with the targets that your plant or your regulator uses. If a value changes suddenly, check the input data and the units before you adjust anything in the plant.

Common mistakes

  • Mixing million gallons with cubic metres. Stay in one unit system.
  • Using the clarifier volume for sludge age. Only the aeration tank counts.
  • Entering MLSS where MLVSS is needed. They are different measures.
  • Reading SVI as a percentage. It is in mL per g.

What next

Use this often? Add Wastewater to your Home screen.

Frequently asked questions

What is a wastewater calculator?

A tool that works out the control measures of an activated sludge plant: F/M, HRT, MCRT, sludge age and SVI.

What is the F/M ratio?

The BOD fed to the aeration tank each day divided by the mass of microorganisms in it.

How is hydraulic retention time worked out?

Divide the tank volume by the flow, with both in the same volume unit.

What is a good sludge volume index?

The tool treats 100 to 200 mL per g as desirable and 80 or less as very dense. These are our own planning bands.

Can I use COD instead of BOD?

Yes, but only compare the result with targets that are based on COD.