A thermal resistance calculator finds how strongly a wall, a pipe wall or a hollow sphere resists the flow of heat. For a wall, enter its area and up to three layers, each with a thickness and a conductivity, and the layers are added in series. It gives the resistance in kelvin per watt, the R-value, and the heat flow if you add a temperature difference.
How to use the thermal resistance calculator
- Choose US or metric units and the shape.
- Enter the dimensions and the conductivity of each layer.
- Add a temperature difference for the heat flow, if you like.
- Press Calculate.
What thermal resistance is
Thermal resistance is the temperature difference divided by the heat flow, R = (T₂ − T₁) ÷ Q, measured in kelvin per watt, so that ΔT = Q R [1]. A high resistance means little heat passes for a given temperature difference. It is the reverse of conductance. The calculator gives R in K/W for the whole wall, pipe or sphere that you describe.
A flat wall
For a plate, R = t ÷ (k A), where t is the thickness, k the thermal conductivity and A the area [1]. The same relation is written L ÷ (k A) in kelvin per watt in the article on thermal conductivity [3]. A thicker wall or a lower conductivity raises R, and a larger area lowers it, because there is more path for the heat. The calculator applies it to each layer.
Layers in series
For resistances in series, the total resistance is the sum of the resistances [1]. So a wall of three layers has R = L₁ ÷ (k₁ A) + L₂ ÷ (k₂ A) + L₃ ÷ (k₃ A). For 10 square metres of 100 millimetres at k = 0.8, 50 millimetres at 0.04 and 12 millimetres at 0.16, the total is 0.145 K/W.
A hollow cylinder
For a hollow cylinder, such as a pipe wall, R = ln(r₂ ÷ r₁) ÷ (2 π L k), where r₁ and r₂ are the inner and outer radii and L the length [1]. A container with a length of 0.5 metres and radii of 0.1 and 0.2 metres gives, for three materials: glass with k = 0.78, 0.28287 K/W; oak with k = 0.17, 1.2979 K/W; and aluminium with k = 237, 0.000931 K/W.
A hollow sphere
For a hollow sphere the tool uses R = (r₂ − r₁) ÷ (4 π r₁ r₂ k), which is our own working from integrating Fourier's law over spherical shells. With the same radii and glass, the calculator gives 0.51011 K/W. The outer radius must be larger than the inner radius, and the calculator asks you to correct the numbers if it is not.
The R-value
In building work, insulation is quoted as an R-value, a resistance for a given area. The R-value is the thermal resistance of a barrier per unit of exposed area, in K·m²/W in SI units and °F·ft²·h/Btu in US units, and the US value is about 5.678 times the SI value [2]. The calculator multiplies R by the area to give square metres kelvin per watt, then multiplies by 5.678 to give the US value in h·ft²·°F per Btu. That factor also follows from the conductivity conversion 1.730735 ÷ 0.3048 [3].
Heat flow
If you add a temperature difference, the heat flow is Q = ΔT ÷ R, which is the definition of the resistance turned round [1]. For the three-layer wall above with 20 kelvin across it, the flow is 137.93 watts. In US mode the result is also shown in Btu per hour, with 1 watt about 3.412 Btu per hour, our own conversion.
Units
In US mode, wall thicknesses and radii are in inches, areas in square feet, lengths in feet and conductivities in Btu/(h·ft·°F). Metric mode uses millimetres, square metres, metres and W/(m·K). The formulas need metres, so the calculator converts all lengths before it calculates, and Btu/(h·ft·°F) is converted at 1.730735 W/(m·K) [3].
Limits
The formulas treat each layer as uniform, with perfect contact between layers, and heat that flows straight through. Real walls have air films on both faces, studs that bridge the insulation, and moisture, so measured values differ. For a building design, use tested R-values and local rules. The critical radius for pipe insulation is not included.
Using the heat flow result
Add a temperature difference to turn the resistance into a heat flow. For a wall with a resistance of 0.145 K/W and 20 kelvin across it, the flow is 137.93 watts, and in an hour about 497 kilojoules leave through it. A higher total resistance means a lower flow, so adding a layer of insulation, which has a low conductivity, cuts the flow much more than adding the same thickness of brick or concrete.
Comparing the three shapes
A flat wall has the same area at every depth, so its resistance is simply its thickness divided by k A. A pipe wall has a larger outer surface than inner, so the heat spreads out as it travels, and the logarithm in the formula reflects that [1]. A sphere spreads the heat even more. Use the cylinder mode for an insulated pipe or a hot tank wall and the sphere mode for a ball-shaped vessel, entering the radii of the inside and the outside surfaces.
Common mistakes
- Entering thickness in the wrong unit. Use inches in US mode and millimetres in metric mode.
- Leaving a conductivity out of a layer. Give both the thickness and k, or leave both blank.
- Swapping the inner and outer radius. The outer radius must be larger.
- Comparing US and SI R-values. They differ by a factor of 5.678.
What next
Use this often? Add Thermal Resi to your Home screen.
Frequently asked questions
What is a thermal resistance calculator?
A tool that finds the resistance to heat flow of a wall, a pipe wall or a sphere.
What is the formula for thermal resistance?
For a flat layer, R = t ÷ (k A), in kelvin per watt.
How do I add layers?
Resistances in series add, so R = L₁ ÷ (k₁ A) + L₂ ÷ (k₂ A) + and so on.
How is R-value related to thermal resistance?
The R-value is the resistance for a given area, R times A, shown in SI and in US units.
How do I find the resistance of a pipe wall?
Use R = ln(r₂ ÷ r₁) ÷ (2 π L k) with the radii and length.
Sources
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.