Heat loss = U × area × ΔT for each surface, plus volume × ΔT × ACH × 0.018 (US) or 0.33 (metric).

Total heat loss

–

Enter the temperatures and at least one surface.

See full result

The heat loss calculator works out how much heat a room or house loses on a cold day, in BTU per hour (or watts in metric). Heat escapes through every wall, window, door, ceiling and floor that faces the cold, and with the outside air that leaks in. Enter the temperatures, each surface’s area and insulation value, and the room’s volume and air changes per hour, and it adds up every part. The total is the heat output your heating has to supply to keep the room warm. For example, a 25 × 15 ft room with insulated walls and ceiling loses about 3,200 BTU/h when it is 68°F inside and 40°F outside.

The heat loss formulas

Warmup’s guide to calculating heat loss sets out the standard method:

  • Through each surface: heat loss = U × A × ΔT, where U is the U-value, A the area and ΔT the difference between inside and outside temperature. U is 1 ÷ R, so a wall with an R-value of 13 has a U-value of about 0.077.
  • Air infiltration: heat loss = room volume × ΔT × air changes per hour × 0.018, where 0.018 BTU per cubic foot per °F is the heat that air holds.
  • Total: add the losses for walls, windows, doors, ceiling, floor and air.

In metric units the calculator works in watts, with U-values in W/m²·K and an air factor of 0.33 W per cubic meter per °C.

How to use the heat loss calculator

  1. Choose US or metric units.
  2. Enter the indoor temperature (70°F or 21°C if blank) and the outdoor design temperature: a typical cold winter temperature for your area.
  3. For each surface that faces outside or an unheated space, enter its area and its R-value (walls, ceiling, floor) or U-factor (windows, doors). Leave a surface blank to skip it.
  4. Measure wall area without the windows and doors, as they are entered separately.
  5. Enter the room volume and air changes per hour for air leakage.

Worked example

A room 25 ft long, 15 ft wide and 8 ft high, with 68°F inside and 40°F outside (ΔT = 28°F), the example Warmup uses:

  • Walls: 164 sq ft at R-13: 164 × 28 ÷ 13 = 353 BTU/h
  • Windows: 36 sq ft at U-0.30: 0.30 × 36 × 28 = 302 BTU/h
  • Ceiling: 375 sq ft at R-38: 375 × 28 ÷ 38 = 276 BTU/h
  • Air: 3,000 cubic feet × 28 × 1.5 air changes × 0.018 = 2,268 BTU/h
  • Total: about 3,200 BTU/h, or about 938 watts

Notice that air leakage is by far the biggest part in this example. That is common in older or drafty rooms, and it is why sealing gaps around windows, doors and attic hatches can cut heating bills so much.

Where to find R-values and U-factors

  • Insulation is labeled with its R-value, such as R-13 for 2×4 walls or R-38 for attics. The whole wall is a little different from the insulation alone, but the label is a good starting point.
  • Windows and doors carry a U-factor on their NFRC label. Lower is better: double-pane windows have a lower U-factor than single-pane ones.
  • Metric values are RSI (m²·K/W) for insulation and U in W/m²·K for windows.

Choosing air changes per hour

Air changes per hour (ACH) describe how often the room’s air is replaced by outside air leaking in. Warmup’s example uses 1.5 air changes per hour for a typical room. Tight, well-sealed modern homes leak less and older homes leak more. A blower door test by an energy auditor measures your home’s real leakage, which gives a much better figure than a guess.

Using the result

The total is the heat the room loses at your design temperature, so your heating must be able to supply at least that much. For a whole house, work out each room and add them up, or use the house’s total wall, window and ceiling areas. The furnace size calculator gives a quicker rule-of-thumb estimate for a whole home, and the BTU calculator sizes air conditioning. Warmup recommends working with an energy professional for a full assessment, and HVAC contractors size systems with an ACCA Manual J load calculation.

Ways to cut heat loss

  • Seal air leaks first: they are often the biggest loss.
  • Add attic insulation; the insulation calculator can work out how much.
  • Upgrade or add storm windows to lower the window U-factor.
  • Insulate floors over unheated crawl spaces and garages.

Metric units

In metric mode, enter temperatures in degrees Celsius, areas in square meters and the room volume in cubic meters. Walls, ceilings and floors take an RSI value in m²·K/W, the metric equivalent of R; windows and doors take a U-value in W/m²·K. The calculator then gives the heat loss in watts, with the BTU per hour figure in the table so you can compare equipment rated either way.

Rooms next to unheated spaces

A wall or floor next to an unheated garage, attic or crawl space also loses heat, but less than one facing the outdoors, because that space is warmer than outside. A simple approach is to include it with the outdoor temperature for a safe, slightly high estimate.

This is a simplified steady-state estimate. It doesn’t include heat gains from sun, people and appliances, or losses through ducts and the ground.

What next

Use this often? Add Heat Loss to your Home screen.

Frequently asked questions

How does the heat loss calculator work?

It adds U × area × temperature difference for each wall, window, door, ceiling and floor, plus volume × temperature difference × air changes × 0.018 for air leakage.

How do I convert an R-value to a U-value?

Divide 1 by the R-value. R-13 is a U-value of about 0.077, and R-38 about 0.026.

What outdoor temperature should I use?

A typical cold winter temperature for your area, called the design temperature. Your HVAC contractor or local weather data can tell you.

Why is air infiltration so large?

Cold air leaking in must be heated. In a drafty room it can be more than all the walls and windows together, so sealing leaks pays off.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Everyday Life Tools