The furnace size calculator gives a quick estimate of how big a furnace your home needs. Enter the heated floor area, choose your climate and how well the house is insulated, and it estimates the heating output in BTUs per hour (BTU/h). Enter the furnace’s efficiency (AFUE) and it also works out the input rating to look for on the label. For example, a 2,000 sq ft home in a moderate climate with average insulation needs about 90,000 BTU/h of heat, which is a furnace with about 112,500 BTU/h input at 80% AFUE.
BTUs per square foot by climate
Bryant, a US furnace maker, gives this rough guide as a starting point:
| Climate region | BTUs per sq ft | 2,000 sq ft home |
|---|---|---|
| Warm (South, Southwest) | 30–35 | 60,000–70,000 |
| Moderate (Midwest, Mid-Atlantic) | 40–50 | 80,000–100,000 |
| Cold (Northeast, northern Midwest) | 50–60 | 100,000–120,000 |
The calculator uses the low end of the range for a well-insulated home, the middle for average insulation and the high end for a poorly insulated or drafty one.
How to use the furnace size calculator
- Choose US or metric units.
- Enter the heated floor area of the home. Leave out garages and unheated basements.
- Enter the ceiling height if it isn’t about 8 ft; taller ceilings mean more air to heat.
- Choose your climate region and insulation level.
- Enter the furnace’s AFUE to see the input rating (80% if blank).
Output vs. input: what AFUE means
A furnace has two BTU ratings. The input is the fuel it burns each hour; the output is the heat it delivers to your home. AFUE (Annual Fuel Utilization Efficiency) is the share of the fuel that becomes usable heat. Carrier notes that natural gas furnaces sold in the US generally must reach at least 80% AFUE, while high-efficiency models reach up to 98.5%. So:
- Input BTU/h = output needed ÷ AFUE
A home that needs 90,000 BTU/h of heat needs a furnace with 112,500 BTU/h input at 80% AFUE, but only about 94,700 at 95% AFUE.
Worked examples
- Moderate climate: 2,000 sq ft, average insulation, 8 ft ceilings: 45 BTU per sq ft × 2,000 = 90,000 BTU/h output; 112,500 BTU/h input at 80% AFUE.
- Cold climate: 2,000 sq ft, poor insulation: 60 × 2,000 = 120,000 BTU/h output; about 126,300 BTU/h input at 95% AFUE.
- Warm climate, tall ceilings: 1,500 sq ft, good insulation, 9 ft ceilings: 30 × 1,500 × 9 ÷ 8 = 50,625 BTU/h output.
Why size matters
Both Carrier and Bryant warn against simply buying the biggest furnace. An oversized furnace heats the house too quickly and turns on and off often, called short cycling, which leads to uneven temperatures, more wear and wasted fuel. An undersized furnace runs constantly and still struggles to keep up on the coldest days. The right size has just enough capacity for your home’s heat loss.
Why this is only an estimate
Square footage and climate give a rough starting point, but Carrier stresses that square footage alone shouldn’t be used to choose a furnace. The professional method is an ACCA Manual J load calculation, which accounts for your insulation, windows, air leakage, ceiling heights, orientation and local design temperatures. Use this calculator to check whether a quote is in the right range, then ask your HVAC contractor for a load calculation before you buy.
Ways to need a smaller furnace
- Seal air leaks around doors, windows and attic hatches.
- Add attic insulation; the insulation calculator can help.
- Upgrade old windows or add storm windows.
- Seal and insulate ducts that run through unheated spaces.
Which climate region am I in?
Bryant groups the country into three broad regions. Warm covers the South and Southwest, such as Texas, Florida and Arizona. Moderate covers the Midwest and Mid-Atlantic, such as Missouri, Virginia and southern Ohio. Cold covers the Northeast and the northern Midwest, such as Maine, Minnesota and Michigan. If your home is in a mountain area or near the border between regions, choose the colder one, and treat the result as a starting point for a professional load calculation.
Ceiling height
The BTU-per-square-foot figures assume a standard ceiling of about 8 ft. Bryant notes that furnace sizing depends on the volume of air in the home, so higher ceilings increase the BTUs needed. The calculator scales the result by your ceiling height divided by 8: a home with 10 ft ceilings needs about a quarter more heat than the same floor area with 8 ft ceilings. For a home with mixed ceiling heights, enter an average.
Gas, propane, oil or electric
The heating output your home needs is the same whatever the fuel. The input rating and AFUE apply to fuel-burning furnaces. An electric furnace turns nearly all of its electricity into heat, so its output is close to its rating; the table shows the output in kilowatts too, which helps compare electric models. A heat pump is sized differently, by its heating capacity at your local winter temperatures.
Replacing an old furnace
When you replace an old furnace, don’t just copy its size. Many older homes have furnaces larger than they need, especially if insulation, windows or air sealing have been improved since it was installed. A load calculation often shows that a smaller, more efficient furnace will keep the home comfortable and cost less to run.
For cooling, size an air conditioner with the BTU calculator or the AC tonnage calculator.
What next
Use this often? Add Furnace Size to your Home screen.
Frequently asked questions
How does the furnace size calculator estimate BTUs?
It multiplies the heated area by a BTU-per-square-foot figure for your climate and insulation, adjusts for ceiling height, and divides by AFUE to get the input rating.
What size furnace do I need for 2,000 square feet?
Roughly 60,000 to 70,000 BTU/h of output in a warm climate, 80,000 to 100,000 in a moderate one and 100,000 to 120,000 in a cold one.
What is the difference between furnace input and output BTUs?
Input is the fuel burned per hour; output is the heat delivered. Output = input × AFUE, so an 80% AFUE furnace with 100,000 BTU/h input delivers 80,000.
Is a bigger furnace better?
No. An oversized furnace short cycles, heats unevenly and wears faster. A Manual J load calculation finds the right size.