A sump pump size calculator helps you choose a pump that can keep up with the water coming into your pit. It turns a simple fill test into the flow your pump needs, adds up the friction in the discharge pipe, and gives the total head to look for on a pump curve.
How to use the sump pump size calculator
- Measure the width of the pit and note the lowest water level.
- Switch the pump off or unplug it for a short time, mark the water level, and time how many seconds the water takes to rise by a few inches or centimetres.
- Measure the vertical lift from the lowest water level to where the discharge pipe ends, the pipe length and the pipe inside diameter.
- Add the extra pipe length for elbows and valves if you know it, and keep or change the safety margin.
- Press Calculate.
Step 1: the water coming in
The pit is a cylinder, so the volume of water added during the test is the area of the pit times the rise. Dividing by the time gives the inflow rate. This part is our own working, not a published rule. For example, an 18 in wide pit that rises 4 in in 30 seconds takes in about 1,018 cubic inches, which is 4.41 US gallons, so the inflow is about 8.81 gallons per minute.
A pump should move more water than flows in. The calculator adds a safety margin of 50 percent by default, our own rule of thumb that you can change. That turns 8.81 into about 13.2 gallons per minute. Heavy storms can bring more water than a dry-day test, so a larger margin is wise where flooding is a risk.
In metric units the same steps apply: the pit width and rise are in centimetres, the volume in litres and the flow in litres per minute. One US gallon is 3.785 litres, so 8.81 gallons per minute is about 33.4 litres per minute. A short test can mislead if the water rises very fast or the pit has a sloping wall, so time a rise of several inches, not a fraction of one. If the pit is not round, enter the diameter of a round pit with the same floor area.
Step 2: total dynamic head
The Sump and Sewage Pump Manufacturers Association (SSPMA) sizing guide says total dynamic head is the static head plus the friction head. [1] The guide is written for sewage pumps, but the head method is the same for a sump pump. Static head is the vertical distance from the minimum water level in the basin to the point of discharge. [1] The point of discharge may not be the highest point in the pipe, and the guide says a pump must have a shut-off head greater than the highest point in the pipe system. [1]
Friction head is the extra head caused by resistance to flow in the discharge pipe. The guide counts fittings by converting them to equivalent feet of straight pipe, and its example adds 5.2 ft for each 2 in elbow and 17.2 ft for a 2 in check valve. [1] Enter that equivalent length in the fittings box, and the calculator adds it to the pipe length.
For the friction itself the calculator uses the Hazen-Williams equation with C = 150 for PVC, unless you enter another value. [2] Our example uses 15 ft of pipe plus 10 ft for fittings in 1.5 in PVC at 13.2 gallons per minute. That gives a friction head of about 0.40 ft, so with an 8 ft static head the total dynamic head is about 8.40 ft.
| Step | Example value |
|---|---|
| Pit 18 in, rise 4 in in 30 s | 8.81 gal/min inflow |
| With 50 percent margin | 13.2 gal/min |
| Static head | 8 ft |
| Friction head, 25 ft of 1.5 in PVC | 0.40 ft |
| Total dynamic head | 8.40 ft |
Step 3: read the pump curve
Look for a pump whose curve delivers at least your design flow at your total dynamic head. In the SSPMA example the head is 10 ft, so the pump must give its required flow at 10 ft. [1] The guide adds that the most efficient part of a pump curve is usually in the middle, away from maximum head or flow, and that more horsepower or flow is not always better, especially in smaller basins. [1] It also notes that short cycling may reduce the life of the pump. [1]
Tips for a better sump pump estimate
- Time the test a few times, ideally after rain, and use the fastest rise.
- Use the inside diameter of the discharge pipe, not the outside size.
- Measure the static head to the end of the pipe, and check the highest point of the pipe as well.
- If the discharge pipe is long, run the longest and the shortest case.
- A pipe that is too small raises the friction head and cuts the flow you actually get.
Common mistakes
- Measuring the water rise in a pit that is also being pumped.
- Using the pit depth instead of the vertical lift to the discharge point.
- Forgetting elbows and a check valve, which can add as much equivalent length as the pipe itself.
- Choosing a pump by horsepower alone instead of its curve.
This calculator gives a planning estimate. Local building rules, backup power, a battery or water-powered backup pump and the discharge location all matter in a real installation. Ask a licensed plumber or the pump maker to confirm the choice.
What next
Use this often? Add Sump Pump Si to your Home screen.
Frequently asked questions
How does a sump pump size calculator find the flow I need?
It uses a timed fill test. The pit volume added during the rise, divided by the time, gives the inflow in gallons per minute. A safety margin is added on top.
What is total dynamic head for a sump pump?
It is the static head plus the friction head. Static head is the vertical lift from the lowest water level to the discharge point, and friction head is the loss in the discharge pipe and fittings.
How much safety margin should I add?
The calculator uses 50 percent by default, which is our own rule of thumb. Use more where flooding would be costly or where heavy storms can bring much more water than your test showed.
Does the calculator include elbows and check valves?
Yes, if you enter them as extra pipe length. The SSPMA guide converts fittings to equivalent feet of straight pipe, and the calculator adds that length to the discharge pipe.
Can I pick a pump by horsepower alone?
No. Compare the pump curve with your flow and total dynamic head, because a pump with more horsepower may not deliver more water at your head.
Sources
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.