Use this skin depth calculator to find how deep an alternating current flows into a conductor at a given frequency, for copper, gold, lead or a custom resistivity.

Restored your last values ·

µΩ·cm

Choose copper, gold, lead or a custom resistivity, enter the frequency with its unit, and optionally the relative permeability and the diameter of your conductor. You get the skin depth, how fast the current fades with depth, and a comparison with your conductor.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose the conductor, enter the frequency, then press Calculate.

See full result

A skin depth calculator finds how far an alternating current penetrates into a conductor. At high frequencies the current crowds into a thin layer at the surface, and the calculator gives the thickness of that layer for copper, gold, lead or any material whose resistivity you know.

How to use the skin depth calculator

  1. Choose the conductor, or custom and enter its resistivity in µΩ·cm.
  2. Enter the frequency and pick its unit.
  3. Optionally add the relative permeability and the diameter of your wire.
  4. Press Calculate.

What skin depth is

The skin effect pushes an alternating current towards the outside of a conductor. The skin depth is the depth below the surface at which the current density has fallen to 1/e, about 37 percent, of its value at the surface [1]. A wire whose radius is smaller than this depth carries current through nearly all of its cross-section.

The formula

The skin depth is δ = √(ρ ÷ (π f μ₀ μᵣ)), where ρ is the resistivity, f the frequency, μ₀ = 4π × 10⁻⁷ henry per metre the permeability of free space, and μᵣ the relative permeability. This is the same as the form δ = √(2ρ ÷ (ωμ)), with ω = 2πf and μ = μᵣ μ₀, that Wikipedia gives [1]. The depth shrinks as the square root of the frequency rises.

Copper at mains frequency

Wikipedia's table for copper gives 9,220 micrometres at 50 hertz and 8,420 at 60 hertz [1]. With ρ = 1.678 µΩ·cm and μᵣ = 0.999, the calculator gives 9.225 mm at 50 hertz. As the depth is about 9 millimetres, the skin effect in a household wire under a centimetre across is small.

Copper at high frequency

At 2.4 gigahertz, the frequency used by Wi-Fi, the calculator gives a skin depth of about 1.33 micrometres for copper, which follows from the 2.06 micrometres that Wikipedia lists at 1 gigahertz by the square-root rule [1]. Wikipedia's table shows the same square-root trend: 65.2 micrometres at 1 megahertz, 6.52 at 100 megahertz and 2.06 at 1 gigahertz [1]. At such frequencies the current flows in a very thin layer, so the resistance of a wire is much higher than at direct current, and the surface finish matters.

Other conductors

The tool has presets for copper, gold and lead. Wikipedia gives a resistivity of 2.44 × 10⁻⁸ ohm metres for gold and 2.2 × 10⁻⁷ ohm metres for lead [1], which are 2.44 and 22 µΩ·cm. With those values, gold at 50 hertz gives 11.12 millimetres, which matches the 11.1 millimetres quoted for gold in the article [1]. For aluminium, silver or an alloy choose custom and type its resistivity from your own data.

Magnetic materials

The relative permeability μᵣ matters when the conductor is magnetic. The formula divides by it under the square root, so a metal with a permeability of 100 has a skin depth ten times smaller than a non-magnetic one with the same resistivity. That is our own consequence of the formula. For copper, gold and lead, leave the box blank, since the value is very close to 1.

How the current fades

The definition says that the current density is 1/e of the surface value at one skin depth. If the fall continues as an exponential, which is our own working, it is about 13.5 percent at two depths and about 5 percent at three. The calculator prints these depths so that you can judge how much of a thick conductor carries current. It does not model the proximity effect or the shape of a real wire.

Comparing your wire

If you enter a diameter, the calculator compares it with the skin depth. It says how many times larger the wire is, and whether the radius is more than one skin depth. When the radius is smaller, the current reaches the centre and the skin effect is small. When it is larger, the current crowds towards the surface. The one-skin-depth rule is a simple reading of the definition, not a design limit.

Units

Resistivity is entered in microohm centimetres, and converted with 1 µΩ·cm = 10⁻⁸ Ω·m. The frequency can be in hertz, kilohertz, megahertz or gigahertz. The depth is shown in metres, millimetres, micrometres or nanometres as suitable, with the value in inches next to it. US mode puts the inches first, and metric mode puts the metric value first.

Limits

The formula applies to a good conductor, in which the displacement current can be neglected, at one frequency. The article notes that the depth approaches a limiting value at frequencies much higher than 1/(ρε), but this tool does not model that region. Temperature raises resistivity and so the skin depth. Use a field solver or measurement for precision work, such as RF design or induction heating.

Checking a wire against the skin depth

Here is our own example for copper. The skin depth scales with the inverse square root of frequency, so starting from 65.2 micrometres at 1 megahertz [1], a frequency ten times lower gives 65.2 × √10 = 206.2 micrometres at 100 kilohertz. A frequency ten times higher gives 65.2 ÷ √10 = 20.6 micrometres at 10 megahertz.

Now compare a wire. At 100 kilohertz, a wire 1 millimeter across has a radius of 500 micrometres, about 2.4 times the skin depth. Current then travels mostly in the outer layer, and the copper in the middle adds little. A wire 0.2 millimeter across has a radius of 100 micrometres, which is less than the skin depth, so nearly all of its cross-section carries current. Use this kind of check to choose a wire diameter for a given frequency.

Common mistakes

  • Typing the frequency in the wrong unit. Check Hz, kHz, MHz and GHz.
  • Entering resistivity in ohm metres. The box expects µΩ·cm.
  • Treating the skin depth as the total depth reached. Current extends deeper but falls off.
  • Ignoring permeability for iron or nickel. Enter μᵣ for magnetic metals.

What next

Use this often? Add Skin Depth to your Home screen.

Frequently asked questions

What is a skin depth calculator?

A tool that finds how deep an alternating current penetrates into a conductor.

What is the skin depth formula?

The depth is the square root of resistivity over pi times frequency times mu zero times relative permeability.

What is the skin depth of copper at 50 Hz?

About 9.2 millimetres, according to Wikipedia.

Why does skin depth fall with frequency?

It is inversely proportional to the square root of the frequency.

What does 1/e mean in the definition?

The current density has dropped to about 37 percent of its surface value.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Physics & Science Tools