A conductivity to resistivity calculator converts between the electrical conductivity and the resistivity of a material, which are the reciprocals of each other. It also finds the resistance of a round wire from its material, length and diameter, with typical values for copper, aluminium, silver, gold and iron.
How to use the conductivity to resistivity calculator
- Choose what you want.
- Enter the conductivity or the resistivity, or the wire data.
- Press Calculate.
Reciprocals
The conductivity σ is the reciprocal of the resistivity ρ: σ = 1 ÷ ρ [1]. The SI unit of resistivity is the ohm metre, and that of conductivity is the siemens per metre [1]. A material that conducts well has a low resistivity and a high conductivity. Copper, with a conductivity of about 59.6 million siemens per metre, has a resistivity of about 1.68 × 10⁻⁸ ohm metres.
Resistivity units
Resistivity is also often given in microhm centimetres or ohm centimetres. One ohm metre is 100 ohm centimetres and 10⁸ microhm centimetres. A resistivity of 1.68 microhm centimetres is therefore 1.68 × 10⁻⁸ ohm metres. The calculator accepts all three units and gives the conductivity in siemens per metre and in megasiemens per metre, which suits metals.
An intrinsic property
The page notes that resistivity is intrinsic: all pure copper wires have the same resistivity, whatever their shape or size [1]. The resistance of a particular wire depends on its shape as well. The resistance of a cube of 1 metre on each side, with contacts on opposite faces, equals the resistivity in numbers, in ohms [1]. That helps to picture the unit.
Resistance of a wire
The resistance of a uniform wire is R = ρ ℓ ÷ A, where ℓ is its length and A its cross-sectional area [1]. For a copper wire of 100 metres and 2 millimetres in diameter, the area is 3.1416 square millimetres, and the resistance is 0.5348 ohms, or 5.35 ohms per kilometre. The calculator does this for a round wire in feet and inches or in metres and millimetres.
Typical values
The calculator has typical values at 20 degrees Celsius: silver 1.59, copper 1.68, gold 2.44, aluminium 2.82 and iron 9.70, all in 10⁻⁸ ohm metres. These are standard handbook figures, and the table on the page that we read gives similar values, but we could not check it word for word, so please compare with a handbook for important work. Annealed copper is a little higher, about 1.72.
Material choice
A wire of aluminium of the same length and diameter as a copper one has a resistance 1.68 times as high, since 2.82 ÷ 1.68 = 1.68. To get the same resistance from aluminium, the cross-section has to be 68 percent larger. This comparison, our own, is why aluminium cables are thicker for the same current, but they are also lighter.
Temperature
Resistivity depends on temperature. In metals, the resistance rises with temperature as the lattice vibrations scatter the electrons more, and impurities also raise it [1]. The calculator uses the values at 20 degrees. A copper wire at 70 degrees has a resistance about 20 percent higher, a rough figure of our own. For exact work, use the temperature coefficient of the material.
Other conductors
For another material, choose the last option and enter its resistivity in microhm centimetres, in the box. For electrolytes, the page says that the resistivity depends strongly on the concentration of ions [1], so a single figure is not enough. The wire formula works for any material with a uniform cross-section and a steady current.
Units
In US mode, the length is in feet and the diameter in inches. The calculator converts them to metres, finds the area of the circle, and gives the resistance in ohms and in ohms per kilometre. A wire of 0.0787 inches, 2 millimetres, over 328 feet, 100 metres, gives the same 0.5348 ohms. The conversion factors, 0.3048 and 0.0254, are our own.
Using the calculator
Pick the mode. For a conversion, enter the value in the unit that you have, and read the other. For a wire, choose the material, the length and the diameter. The working line gives the resistivity and the area that were used. To find the diameter for a target resistance, try values until the resistance matches.
Quick conversions
To go from megasiemens per metre to ohm metres, divide 1 by the number and by a million. 58 MS/m, the figure for annealed copper, is 1.724 × 10⁻⁸ ohm metres. To go from microhm centimetres to ohm metres, multiply by 10⁻⁸, so that 2.82 microhm centimetres is 2.82 × 10⁻⁸ ohm metres. The calculator does these steps for you, and the working line shows the value in SI units.
Choosing wire for a run
For a long run of cable, the resistance sets the voltage drop. A copper wire of 2 millimetres over 100 metres has 0.53 ohms. At a current of 10 amperes, the drop in the one wire is 5.3 volts, and in a two-wire circuit twice that. If this is too much, use a thicker wire: doubling the diameter divides the resistance by four. The wire size and voltage drop calculators on this site go further, and the calculator here gives the basic resistance for a chosen material.
Common mistakes
- Mixing microhm centimetres and ohm metres. Check the unit.
- Using the radius as the diameter. The box takes the diameter.
- Ignoring temperature. Resistance rises with heat.
- Using a handbook value for an alloy. Alloys vary.
What next
Use this often? Add Conductivity to your Home screen.
Frequently asked questions
What is a conductivity to resistivity calculator?
A tool that converts between conductivity and resistivity, and finds the resistance of a wire.
How are conductivity and resistivity related?
σ = 1 ÷ ρ.
What is the resistivity of copper?
About 1.68 × 10⁻⁸ Ω·m at 20 °C.
What is the formula for the resistance of a wire?
R = ρ ℓ ÷ A.
What units are used?
Ohm metres for resistivity and siemens per metre for conductivity.
Was this tool helpful?