Saved

Press the star next to a tool's name to save it.

All my tools

Qpcr Efficiency Calculator

Use this qPCR efficiency calculator to turn the slope of a standard curve into amplification efficiency, fit a curve from your points, and convert a Cq difference to a fold change.

Restored your last values ·

Enter the slope of your standard curve to get the amplification efficiency, or type the points of the curve and let the calculator fit the line. You can also turn a difference in Cq values into a fold difference in the starting amount.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the slope or your standard curve points, then press Calculate.

A qPCR efficiency calculator turns the slope of a standard curve into the amplification efficiency of a real-time PCR assay. Enter the slope, or type the points of the curve, and you get the efficiency as a percentage and the increase per cycle. It also converts a difference in Cq values into a fold difference in the starting amount.

How to use the qPCR efficiency calculator

  1. Choose whether you have the slope, the points of the curve or a difference in Cq.
  2. Enter the slope, or one point per line with the log10 of the quantity and its Cq.
  3. For a fold difference, enter the Cq difference and the efficiency.
  4. Press Calculate.

What the standard curve shows

In real-time PCR the quantity of the target template doubles every cycle [1]. A standard curve plots the Cq of a dilution series against the logarithm of the quantity, and the slope of the fitted line determines the efficiency of amplification [1]. The efficiency is 100 percent when a 1 to 2 dilution gives a Cq difference of 1 [1].

The formula

The usual formula is E = 10 raised to the power of minus 1 over the slope, minus 1. It is the standard form that we use, and it is not written on the page that we read. With a slope of minus 3.32, E is 1.0008, so the efficiency is 100.08 percent. A slope of minus 3.6 gives 89.57 percent, and a slope of minus 3.1 gives 110.17 percent. The slope for exactly 100 percent is minus 1 over the log10 of 2, which is minus 3.3219, so a curve with that slope has a doubling in each cycle.

Fitting your points

Enter one pair per line: the log10 of the quantity or dilution, then the Cq. For example 1 and 30, 2 and 26.7, 3 and 23.4, 4 and 20.1 lie on a line of slope minus 3.3, and the calculator reports an efficiency of 100.92 percent. The calculator uses ordinary least squares, shows the line and its R squared, and uses the fitted slope in the formula. Use dilutions that cover the range of your samples, and repeat the points to see the spread.

Fold difference from Cq

A difference of one cycle means one doubling at 100 percent efficiency. The page gives the example that a sample whose Cq comes 3 cycles earlier than another contained 2 to the power 3, which is 8 times more template [1]. The calculator generalizes to other efficiencies: the fold difference is one plus the efficiency, raised to the power of the Cq difference. At 90 percent efficiency, 2 cycles give 1.9 squared, which is 3.61.

Reading the result

An efficiency near 100 percent means the template doubles in each cycle. A much lower value points to inhibitors, poor primer design or a bad dilution series, and a value above 100 percent often comes from pipetting errors or inhibition at high concentrations. The page gives no acceptable range, so follow the guidelines of your lab or journal, and report the efficiency as the page's source, the MIQE guidelines, asks.

Limits

The calculator assumes a straight line over the points you give. Points at the extremes can curve and are better left out. It needs a negative slope, since a higher quantity must give an earlier Cq. If your slope is positive, check which way you entered the quantity.

Planning a standard curve

A good standard curve uses at least five dilution points spread evenly on a logarithmic scale, such as tenfold or fivefold dilutions, and covers the range of quantities that your samples will have. Run each point in triplicate, and average the Cq values before you fit the line. A tenfold dilution should shift the Cq by about 3.32 cycles at full efficiency, so use that as a quick check of each step.

Why efficiency matters

When you compare samples by the difference in Cq, you assume that the target doubles in each cycle. If the efficiency is far from 100 percent, the fold change from the simple doubling rule is wrong, and the calculator's fold mode lets you correct for the efficiency that you measured. The same correction is needed when you compare two different genes that have different efficiencies.

Reporting

The page we read points to the MIQE guidelines for the reporting of real-time PCR experiments [1]. State the efficiency, the slope, the range of the curve, the R squared and the number of replicates, so that other laboratories can judge your results. If your curve bends at the highest or lowest dilution, report the range that you used for the fit, and leave out the points that fall off the line, because a bent curve makes the slope and the efficiency unreliable. The fit in this calculator is a simple least-squares line and is for planning and checking.

Common mistakes

  • Entering the quantity instead of its logarithm. The slope must be against log10 of the quantity.
  • Using too few dilutions. Three or more points make a better line.
  • Ignoring replicates. Average replicate Cq values for each dilution.
  • Treating 100 percent as perfect proof. Check the line and the melt curves too.

What next

Use this often? Add Qpcr Efficie to your Home screen.

Frequently asked questions

What is a qPCR efficiency calculator?

A tool that converts the slope of a qPCR standard curve into amplification efficiency and fits the curve from your Cq points.

How do I calculate qPCR efficiency from the slope?

E = 10^(−1/slope) − 1. A slope of −3.32 gives 100.08 percent.

What slope means 100 percent efficiency?

About −3.32, which is −1 divided by log10(2), because the quantity doubles each cycle.

What does a difference of 3 Cq mean?

At 100 percent efficiency, the sample with the lower Cq started with 2 to the power 3, or 8 times, more template.

Why must the slope be negative?

A larger starting quantity reaches the threshold earlier, so Cq falls as the log of the quantity rises.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.