A DNA concentration calculator turns an absorbance reading at 260 nm into a concentration in micrograms per millilitre. Enter the A260 value, choose double-stranded DNA, single-stranded DNA or RNA, and add a path length, a dilution factor and, if you like, the A280 and A230 readings to check purity.
How to use the DNA concentration calculator
- Enter your A260 reading and choose the type of nucleic acid.
- Enter the path length in millimetres if it is not 10, and a dilution factor if you diluted the sample before measuring.
- Add a volume to see the total amount, and the A280 and A230 readings to see the purity ratios, then press Calculate.
The conversion factors
The Wikipedia article on nucleic acid quantitation gives the conversion factors for an A260 of 1: double-stranded DNA is 50 μg/mL, single-stranded DNA is 33 μg/mL and single-stranded RNA is 40 μg/mL.[1] It gives the matching extinction coefficients as 0.020, 0.027 and 0.025 per μg/mL per cm.[1] For a 10 mm path, you simply multiply the optical density by the conversion factor to get the concentration.[1] A 2.0 reading for double-stranded DNA is therefore 100 μg/mL.[1]
Correcting the path length
The page treats a 10 mm path as the reference and says that with a shorter path the optical density falls by a factor of 10 divided by the path length. Its example, for a 3 mm path, is 0.6 × (10 ÷ 3) × 50 μg/mL = 100 μg/mL.[1] The calculator applies this rule. Enter 0.6 and a path length of 3 and you get 100 μg/mL. Most spectrophotometers allow you to select the nucleic acid type and path length so that the result is already normalised to 10 mm.[1]
Dilution
If you diluted the sample before measuring, multiply the result by the dilution factor. The page does not discuss dilution factors, so this step is our own working, and the calculator shows it in the working line. A reading of 0.5 on a 1 in 10 dilution of double-stranded DNA gives 0.5 × 50 × 10 = 250 μg/mL. A concentration in μg/mL is the same as one in ng/μL, which is how many instruments report it. With the volume, the amount in micrograms is the concentration times the volume in microlitres divided by 1,000.
Purity ratios
The page says that pure DNA has an A260/A280 ratio widely considered to be about 1.8, and pure RNA about 2.0.[1] For the A260/A230 check, it describes the ratio A230:A260:A280 as about 1:1.8:1 for DNA and about 1:2:1 for RNA.[1] Dividing gives an A260/A230 of about 1.8 for DNA and 2.0 for RNA, which is our own arithmetic from the page's ratios. The page lists residual phenol or other reagents and very low concentrations, below 10 ng/μL, as causes of a low A260/A280, and carbohydrate carryover, phenol, guanidine and glycogen as causes of a low A260/A230.[1] A high A260/A280 is not normally indicative of any problem.[1] The calculator marks the ratio as close to, lower than or higher than the expected figure, using a margin of 0.1 that is our own choice.
The limit of the method
The page says the conversion is valid up to an absorbance of at least 2.[1] When your reading is above 2 the calculator shows a note asking you to dilute and measure again. At the low end, below 10 ng/μL, the ratios become unreliable.[1] For very dilute samples, or when contaminants absorb at 260 nm, the page says fluorescence methods are useful, though with a higher price per sample and a longer preparation.[1]
Contaminants and blanks
Phenol absorbs with a peak at 270 nm and can significantly contribute to an overestimate of DNA concentration.[1] Negative readings can result if the wrong solution was used as the blank.[1] Measure the blank in the same buffer as your sample, for example TE and not water, and clean the pedestal between readings.
Worked examples
An A260 of 0.6 on a 3 mm path for double-stranded DNA is 100 μg/mL, from the page.[1] The same reading for single-stranded DNA with a 10 mm path is 0.6 × 33 = 19.8 μg/mL, and for RNA it is 24 μg/mL. A reading of 1.0 with A280 0.55 has a ratio of 1.82, close to the DNA figure. These last examples are our own.
Choosing the right type
Use the double-stranded DNA factor for plasmids, genomic DNA and most PCR products, the single-stranded DNA factor for oligonucleotides and single-stranded templates, and the RNA factor for RNA preparations. The page notes that for short oligonucleotides the extinction coefficient depends on the length and base composition, so the single-stranded DNA factor is only an average for them.{1} If you know the exact sequence, use the supplier's value instead.
Checking the blank
Always zero the spectrophotometer with the same buffer that your sample is in. The page notes that a blank on a dirty pedestal or the wrong blank, such as water for samples in TE, gives misleading ratios and sometimes a negative reading.{1} Take two or three readings of the same sample and average them if the values differ by more than a few percent.
Common mistakes
- Using the wrong factor. The factor depends on the nucleic acid type.
- Forgetting the dilution. Multiply by the dilution factor.
- Trusting a ratio at low concentration. Ratios are unreliable below 10 ng/μL.
What next
Use this often? Add DNA Concentr to your Home screen.
Frequently asked questions
What is a DNA concentration calculator?
A tool that converts an absorbance reading at 260 nm into a concentration, using 50 µg/mL per A260 for double-stranded DNA.
How do I calculate DNA concentration from A260?
Multiply the A260 by 50 µg/mL for double-stranded DNA, 33 for single-stranded DNA or 40 for RNA, and by the dilution factor.
How does path length change the result?
The reference is 10 mm. For a shorter path, multiply the reading by 10 divided by the path length in millimetres.
What is a good A260/A280 ratio?
About 1.8 for pure DNA and about 2.0 for pure RNA.
Does a ratio of 1 microgram per millilitre equal 1 nanogram per microlitre?
Yes. The two units are the same, which is why instruments often report ng/µL.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.