A PSI to GPM converter works out how many gallons per minute flow through a valve or fitting for a given pressure drop. Pressure and flow are different quantities, so the link between them is the flow coefficient, Cv, printed on most valve datasheets. Enter the pressure drop in psi and the Cv, add the specific gravity if the liquid is not water, and the converter shows the flow in US gallons per minute, litres per minute and cubic metres per hour.
Why you cannot convert PSI to GPM directly
PSI measures pressure, a force on an area, while GPM measures flow, a volume moving each minute. The same pressure can push a trickle through a small opening or a flood through a large one. What connects the two is the resistance of the path the liquid takes. For valves, that resistance is summed up in a single number, the flow coefficient. Without it, or a similar figure such as an orifice size and its discharge coefficient, no calculator can turn PSI into GPM.
What is the flow coefficient (Cv)?
Wikipedia describes the flow coefficient of a device as a relative measure of its efficiency at allowing fluid flow. In practice, Cv is the volume in US gallons of water at 60 °F that will flow per minute through a valve with a pressure drop of 1 psi across it. A higher Cv means a less restrictive valve. The article gives an example: the flow coefficient of a 1-inch ball valve may be 80, while a similarly sized globe valve in the same application may be 10. The metric equivalent is the flow factor Kv, in cubic metres per hour with the pressure drop in bar, and Wikipedia gives the relation Cv = 1.156 × Kv.
The PSI to GPM formula
Q (US gpm) = Cv × √(ΔP ÷ SG)
ΔP = pressure drop across the valve in psi
SG = specific gravity of the liquid (water = 1)
This is the defining relation for Cv rearranged for flow. Because the flow depends on the square root of the pressure drop, doubling the pressure drop increases the flow by only about 41 percent, and you need four times the pressure drop to double the flow.
How to use the PSI to GPM converter
- Enter the pressure drop, the difference between the pressure just before and just after the valve, in psi.
- Enter the Cv from the valve maker's datasheet. Use the value for the opening you are interested in, since Cv falls as a valve closes.
- Optionally enter the specific gravity of the liquid. Leave it blank for water.
- Press Calculate to see the flow in several units and the matching Kv.
Worked examples
- Cv 10 with a 25 psi drop, water: 10 × √25 = 50 gpm, which is about 189 litres per minute.
- Cv 80 with a 4 psi drop, water: 80 × √4 = 160 gpm.
- Cv 10 with a 25 psi drop and a liquid of specific gravity 1.2: 10 × √(25 ÷ 1.2) = 45.6 gpm. Heavier liquids flow a little less for the same pressure drop.
- Cv 1 with a 1 psi drop, water: exactly 1 gpm, which is the definition of Cv.
Pressure drop, not line pressure
A common mistake is to enter the pressure in the pipe instead of the drop across the valve. A pipe at 60 psi feeding an open tap does not mean 60 psi across the tap if most of that pressure is lost in the pipework before it. Measure the pressure just upstream and just downstream of the valve, or use the drop given in the system design, and subtract one from the other.
Sizing a valve
The same formula works backwards for choosing a valve. If you need 50 gpm of water with a 25 psi drop available, the required Cv is 50 ÷ √25 = 10. Pick a valve whose Cv at the opening you plan to use is at least that figure. Use the converter to try different Cv values and see which one delivers the flow you need at your pressure.
Units
The converter shows the flow in US gallons per minute, litres per minute and cubic metres per hour, and the metric flow factor Kv. To convert other pressure units to psi first, use the pressure converter, and for flow units use the flow rate converter.
Where to find a valve's Cv
Valve makers publish the flow coefficient in their datasheets, often as a table of Cv against the percentage the valve is open. For a simple on and off valve, use the figure for fully open. For a control valve, pick the opening you expect in normal use. If the datasheet gives Kv instead, divide it by the factor in the formula above to get Kv from Cv, or multiply Kv by 1.156 to get Cv, and enter that number in the converter.
Checking a system you already have
If you can measure the pressure on both sides of a valve and you know its Cv, the converter tells you the flow without a flow meter. That is useful when you troubleshoot a slow irrigation zone, a weak shower or a pump that seems to underperform. Compare the result with the flow you expect, and if it is much lower, look for a partly closed valve, a clogged strainer or a pipe that is too small for the job.
Common mistakes
- Using line pressure instead of pressure drop. Use the difference across the valve.
- Using a Cv for a fully open valve when it is partly closed. Cv changes with opening.
- Forgetting the specific gravity. It matters for liquids heavier or lighter than water.
- Applying the formula to gas. Gas flow needs other formulas.
What next
Use this often? Add PSI to GPM to your Home screen.
Frequently asked questions
How does a PSI to GPM converter work?
It uses the flow coefficient formula Q = Cv × √(ΔP ÷ SG), where Q is US gallons per minute, ΔP is the pressure drop in psi and SG is the specific gravity.
Can you convert PSI to GPM without Cv?
No. Pressure and flow are different quantities. You need the flow coefficient of the valve or a similar figure to link them.
What is Cv?
Wikipedia says Cv is the volume in US gallons of water at 60 °F that flows per minute through a valve with a 1 psi pressure drop.
How do Cv and Kv relate?
Wikipedia gives Cv = 1.156 × Kv, where Kv is the metric flow factor in cubic metres per hour with the pressure drop in bar.
How much does flow rise with pressure?
Flow rises with the square root of the pressure drop, so four times the pressure drop doubles the flow.
Sources
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.