A plumbing fixture units calculator adds up the drainage load of the fixtures in a building. Each fixture gets a relative value called a drainage fixture unit, or DFU, and the total is what plumbers use to size drain pipes. This page uses the values in the 2021 International Plumbing Code (IPC). [1]
How to use the plumbing fixture units calculator
- Count your fixtures. Count a bathroom group as one item.
- Enter the number of each fixture type in its box.
- If a drain is known only by its flow in gallons per minute, enter that flow in the last box.
- Press Calculate to see the total DFU and a line-by-line breakdown.
Drainage fixture unit values used
The IPC lists a drainage fixture unit value for each fixture in Table 709.1. [1] The calculator uses these values for the 2021 edition as printed in the Connecticut State Building Code on the UpCodes website.
| Fixture | DFU |
|---|---|
| Bathroom group, 1.6 gpf toilet | 5 |
| Bathroom group, toilet over 1.6 gpf | 6 |
| Toilet, private, 1.6 gpf | 3 |
| Toilet, public, 1.6 gpf | 4 |
| Urinal | 4 |
| Lavatory | 1 |
| Bathtub | 2 |
| Shower, 5.7 gpm or less | 2 |
| Shower, over 5.7 to 12.3 gpm | 3 |
| Kitchen sink, domestic | 2 |
| Dishwasher, domestic | 2 |
| Residential clothes washer | 2 |
| Laundry tray | 2 |
| Floor drain | 2 |
| Service sink | 2 |
Rules the table follows
- A showerhead over a bathtub does not add to the bathtub value. [1]
- A shower is rated by the total flow through its showerheads and body sprays, so a bigger shower can count for more. [1]
- A domestic kitchen sink with a food waste disposer, a dishwasher or both is still 2 DFU. [1]
- For fixtures added to a bathroom group, add the value of those extra fixtures to the group. [1]
- For loads on building drains and sewers, water closets and urinals are not rated lower than the table unless testing confirms a lower value. [1]
Fixtures that are not listed, or devices with an intermittent flow, are rated by other sections of the code. [1] When a discharge is known only in gallons per minute, the code says to treat 1 gpm as equivalent to 2 DFU. [1] The calculator applies that in the last box.
Worked example
A small building has two bathroom groups with 1.6 gpf toilets, a kitchen sink with a dishwasher, a residential clothes washer and a floor drain. There is also a sump pump discharge of 3 gpm. The total is 2 × 5 + 2 + 2 + 2 + 3 × 2, which equals 22 DFU. Enter 2, 1, 1, 1 and 3 and you get the same answer, with five fixtures counted.
Why fixture units are used instead of gallons
Not every fixture is used at the same time. A toilet gives a large burst of water for a few seconds, while a lavatory gives a small, steady flow. Fixture units give each fixture a relative weight for its load on the drain, so that a building with many fixtures is not sized as if every one ran together. The unit has no fixed volume. It is a rating that the code tables turn into pipe sizes, which is why the total is a plain number of units rather than a flow in gallons.
Counting a typical home
Most houses are easy to count. List each bathroom as a group if it has a toilet, a lavatory and a tub or shower. Then add the kitchen sink, the clothes washer standpipe, any laundry tray, the basement floor drain and any extra sink or bar sink. A utility sink is usually rated as a service sink, so check the code if you are unsure. When a bathroom has two lavatories, count the second one on its own. Write the list down first, walk through every floor of the building, and only then enter the counts, so that nothing is missed or counted twice. Rerun the calculator if you add a bathroom later.
What the total is used for
The total DFU is the load figure that the pipe sizing tables of a plumbing code use to select the size of a drain, branch or stack. Those tables vary with slope and code edition, and they are not part of this calculator. Use the total to know your load, then check the sizing table in the code your area follows. The 2021 IPC is only one edition, and the Uniform Plumbing Code, which is used in some states, has its own fixture unit values that can differ.
Tips for counting fixtures
- Count each fixture in the building, including those in the basement and garage.
- Do not double count a bathroom group and its parts.
- A dishwasher that drains into the kitchen sink trap is covered by the kitchen sink value. Use the dishwasher box only for one on its own drain.
- For a shower with several heads, use the combined flow rating to choose the right shower row.
Limits of this plumbing fixture units calculator
Local codes change the adopted values. A few states and cities use their own amendments, and older buildings may follow an earlier edition. The calculator covers the common fixtures only. For anything else, look up the fixture in the code or ask your plumbing inspector. This is an estimate for planning, not a permit document, so a licensed plumber or the local inspector should confirm the final count.
What next
Use this often? Add Plumbing Fix to your Home screen.
Frequently asked questions
What is a plumbing fixture units calculator used for?
It adds up the drainage fixture units of the fixtures in a building. The total is the load figure used with a plumbing code to size drain pipes.
How many DFU is a toilet?
In the 2021 IPC a private 1.6 gpf toilet is 3 DFU and a public one is 4 DFU. A bathroom group with a 1.6 gpf toilet counts as 5 DFU in total.
Does a shower over a bathtub add DFU?
No. The code says a showerhead over a bathtub does not increase the bathtub value, which stays at 2 DFU.
How do I convert gallons per minute to fixture units?
The code treats 1 gpm of flow as equal to 2 DFU when a discharge is known only in gallons per minute. Enter the flow in the last box.
Which code edition are the values from?
The values are from Table 709.1 of the 2021 International Plumbing Code. Your area may use another edition or code, so check with your local inspector.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.