This npsh net positive suction head calculator works out the head available at a pump inlet above the liquid's vapour pressure. Compare it with the NPSH the pump needs, and you can see whether the pump is at risk of cavitation. Enter the surface pressure, the vapour pressure, the density, the height and the friction loss.
How to use the npsh net positive suction head calculator
- Choose US or metric units.
- Say whether the liquid surface is below or above the pump inlet, and enter the height.
- Enter the pressures, the density and the friction loss.
- Add the pump's NPSH required if you know it, and press Calculate.
What NPSH means
Net positive suction head describes how close the liquid at a pump inlet is to boiling. Wikipedia defines the available NPSH as the absolute pressure head minus the vapour pressure of the liquid, and the required NPSH as the head needed at the suction side to keep the liquid from cavitating [1]. Cavitation forms vapour bubbles that collapse and damage the pump, so the aim is to keep the available head above the required head [1].
The formula the calculator uses
Wikipedia gives NPSH = (p_surf − p_vap) ÷ (ρ g) − Z − H_l, where p_surf is the pressure at the liquid surface, p_vap the vapour pressure, ρ the density, g the gravitational acceleration, Z the height between the surface and the pump inlet and H_l the friction loss in the suction line [1]. For an open tank the surface pressure is atmospheric, and for a closed reservoir it is the atmospheric pressure plus the gauge pressure inside.
The sign of the height
The height Z reduces the available head when the liquid is below the pump, which is a suction lift. When the tank is above the pump, Z is negative, so the head rises [1]. The calculator has a drop-down for this, so you always enter the height as a positive number and choose below or above. A flooded suction, with the liquid above the inlet, is the safer arrangement for cavitation.
Worked example in metric units
A worked example is water at 20 °C in an open tank, with atmospheric pressure 101.33 kPa, vapour pressure 2.34 kPa, density 998.16 kg/m³, a pump 1 m above the liquid and 1.7 m of friction loss. The pressure head is (101,330 − 2,340) ÷ (998.16 × 9.81) = 10.109 m, so NPSH = 10.109 − 1 − 1.7 = 7.41 m. The calculator reproduces this, and also shows it in feet, 24.31 ft.
Working in US units
With US units the calculator converts pounds per square inch, pounds per cubic foot and feet to kilopascals, kilograms per cubic metre and metres, applies the same formula, and reports the answer in both feet and metres. The conversion factors are standard unit conversions and our own working, not figures from the sources. The example above, entered as 14.696 psi, 0.339 psi, 62.3 lb/ft³, 3.28 ft and 5.58 ft, gives about 24.3 ft.
Gravity and the liquid
The calculator uses g = 9.81 m/s² and takes the density and vapour pressure at the liquid's temperature. Vapour pressure rises quickly with temperature, which is why hot liquids are the hard case: the same system that is safe for water at 20 °C can cavitate with water at 80 °C. Look up the vapour pressure and density for your actual temperature before you enter them.
Comparing with NPSH required
The pump maker supplies the required NPSH, which is usually found by testing. If you enter it, the calculator subtracts it from the available head. Wikipedia says cavitation will occur when the available NPSH is less than the required NPSH [1], and the margin tells you how far you are from that.
The safety margin
Wikipedia's examples mention a minimum margin of 600 mm and a recommended margin of 1.5 m of head above the required value [1]. The calculator uses those two figures to describe your margin: below zero, below 600 mm, up to 1.5 m, or at least 1.5 m. Treat the wording as a rule of thumb, because the right margin depends on the pump, the liquid and the duty.
What it does not include
The surface-based formula ignores the velocity head at the inlet, which the inlet form of the equation adds [1], and it does not calculate the friction loss for you. You must supply H_l from a pipe-friction calculation or a table. It also does not treat dissolved gases, two-phase flow or changes in flow rate. The result is the available head for the situation you describe, nothing more.
When to use the calculator
Use it to check a pump layout early in a design, to see how much lowering the pump or enlarging the suction pipe would help, or to understand why a pump on a long suction lift struggles. It is a teaching tool. A real installation needs the pump curve, the maker's NPSH required at the duty flow, and a design by a qualified engineer who knows the applicable standards.
Common mistakes
- Using gauge pressure for the surface. The formula needs absolute pressure: add the atmospheric pressure to any gauge pressure.
- Entering the height with the wrong sign. Pick below or above in the drop-down and enter a positive height.
- Using the vapour pressure of water at 20 °C for a hot liquid. Use the value at the actual temperature.
- Forgetting the friction loss. It reduces the head, so a long pipe cuts the margin.
What next
Use this often? Add Npsh Net Pos to your Home screen.
Frequently asked questions
What is an npsh net positive suction head calculator?
A tool that finds the NPSH available at a pump inlet from the pressures, density, height and suction friction, so it can be compared with the NPSH required.
What is the NPSH available formula?
NPSHa = (p_surface − p_vapour) ÷ (ρ g) − Z − H_loss, with Z negative when the liquid is above the pump.
When does a pump cavitate?
When the available NPSH is less than the required NPSH. Wikipedia lists a margin of at least 600 mm and recommends 1.5 m.
Where do I find NPSH required?
From the pump maker's data, usually found by testing at the duty flow.
Does a higher liquid temperature lower NPSH available?
Yes. The vapour pressure rises, so the pressure head above it falls.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.