A noise figure calculator tells you how much a stage, such as an amplifier or a receiver, worsens the signal-to-noise ratio. Give the input and output SNR, or the noise factor, and it returns the noise figure in decibels. List the stages of a receiver chain and it applies the Friis formula to give the total.
How to use the noise figure calculator
- Choose the mode: SNR ratios, SNR in dB, noise factor, noise figure to factor, or a cascade.
- Fill in the boxes that appear. For a cascade, put one stage per line as noise figure in dB, gain in dB.
- Press Calculate and read the noise figure, the noise factor and, for a cascade, the total gain and the contribution of each stage.
What the noise figure is
Every real amplifier or receiver adds some noise of its own, so the signal-to-noise ratio at the output is worse than at the input. The noise figure is NF = 10 × log₁₀(SNRi ÷ SNRo), the logarithm of the input-to-output SNR ratio, and the noise factor is the same idea without the logarithm [1]. In other words, the noise figure is the noise factor expressed in decibels.
Noise factor and noise figure
The noise factor F is a plain ratio, F = SNRi ÷ SNRo, and the noise figure is NF = 10 log₁₀ F [1]. A factor of 1 is a noise figure of 0 dB, the ideal in which the stage adds no noise. Our own conversion for a factor of 2 is 3.01 dB, so a 3 dB noise figure is close to a noise factor of 2. A smaller noise figure is better, and the calculator shows both forms.
Working with SNR in dB
If both SNRs are already in decibels, there is no need for a logarithm: the noise figure is simply the input SNR in dB minus the output SNR in dB. As an example, 40 dB in and 35 dB out give 5 dB [1]. The same two numbers entered as plain ratios would give 0.5799 dB, because they are then read as ratios and not as decibels, so choose the mode that matches how your numbers are written.
Worked example from plain ratios
With an input SNR of 8 and an output SNR of 7, the noise factor is 8 ÷ 7 = 1.1429, and the noise figure is 10 × log₁₀(1.1429) = 0.5799 dB. A second example, 5 and 2, gives a factor of 2.5 and a noise figure of 3.9794 dB. Use these numbers to check the tool by hand.
Cascaded stages and the Friis formula
A real receiver is a chain: an antenna feed, a low-noise amplifier, a filter, a mixer and so on. Wikipedia gives the Friis formula for the total noise factor: F = F₁ + (F₂ − 1) ÷ G₁ + (F₃ − 1) ÷ (G₁ G₂) + …, where each G is a linear power gain [1]. The calculator allows up to 10 stages.
Why the first stage matters most
Because each later term of the Friis formula is divided by the gain in front of it [1], the first stage dominates. That reading of the formula is our own working. The calculator lists each stage's contribution and the share of the first stage, so you can see this at once and decide where a better, lower-noise part would help most.
A worked cascade
Our own example has three stages: a low-noise amplifier with 1 dB noise figure and 20 dB gain, a stage with 6 dB and 10 dB, and a final stage with 10 dB and 0 dB. The linear factors are 1.2589, 3.9811 and 10, and the gains are 100 and 10. The total factor is 1.2589 + 2.9811 ÷ 100 + 9 ÷ 1000 = 1.2977, a total noise figure of 1.1319 dB. The first stage supplies 97% of the noise factor, although the last stage is much noisier.
Units and conversions
Friis' formula needs linear ratios, so the calculator turns each noise figure from dB into a factor with F = 10^(NF ÷ 10) and each gain into G = 10^(gain ÷ 10), and converts the total back at the end. The total gain is the sum of the dB gains, which equals the product of the linear gains.
Negative values and limits
A noise figure below 0 dB would mean the output SNR is better than the input SNR, which an ordinary device cannot do, so the tool assumes the input SNR is the larger. If you see a negative result, the input and output values are probably swapped, and the calculator says so. Noise figures also depend on frequency, temperature and source impedance, so use the datasheet value for your operating point rather than a typical figure.
When to use the calculator
Use it to compare amplifiers, to check how much a lossy cable or filter before the first amplifier will hurt the noise figure, or to confirm a hand calculation. A passive loss of a given number of decibels can be entered as a stage with a noise figure equal to its loss and a negative gain, which is our own working rather than a statement from the sources. For a link budget, pair it with the free-space path-loss and decibel calculators.
Common mistakes
- Adding noise figures in dB. In a cascade the stages combine through the Friis formula, not by adding decibels.
- Using dB gains as ratios. Convert the gain to a linear ratio before dividing, as the tool does for you.
- Swapping input and output SNR. The input SNR is the larger one, so the noise figure comes out positive.
- Ignoring the first stage. It sets most of the total, so improve it first.
What next
Use this often? Add Noise Figure to your Home screen.
Frequently asked questions
What is a noise figure calculator?
A tool that turns input and output signal-to-noise ratios, or a noise factor, into a noise figure in dB, and can combine several stages with the Friis formula.
What is the noise figure formula?
NF = 10 log₁₀(SNRi ÷ SNRo), which is the same as 10 log₁₀ of the noise factor F.
How do I convert a noise figure to a noise factor?
F = 10^(NF ÷ 10). A 3 dB noise figure is a noise factor of about 2.
How do I find the noise figure of a cascade?
Convert each noise figure and gain to linear ratios and use F = F₁ + (F₂ − 1) ÷ G₁ + (F₃ − 1) ÷ (G₁ G₂) + …, then convert back to dB.
Can a noise figure be negative?
Not for an ordinary device. A negative value means the input and output SNR have been swapped.
Sources
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.