A Michaelis-Menten calculator gives the rate of an enzyme-catalysed reaction from the maximum rate, the Michaelis constant and the substrate concentration. It can also work out the turnover number and catalytic efficiency, and the substrate concentration needed for a target rate.
How to use the Michaelis-Menten calculator
- Choose what you want.
- Enter V_max, K_m and the substrate concentration, or the other values the mode asks for.
- Press Calculate.
The equation
The Michaelis–Menten equation gives the rate as v = V_max [S] ÷ (K_m + [S]), where [S] is the substrate concentration [1]. The maximum rate is V_max, and the Michaelis constant K_m is the substrate concentration at which the rate is half of V_max [1]. K_m does not depend on the enzyme concentration or its purity [1]. The calculator solves this equation for the rate, or rearranged for the substrate.
Low and high substrate
At a substrate concentration below K_m the rate is close to first order in the substrate, and at a concentration far above K_m it is close to zero order and approaches V_max [1]. The calculator tells you which regime your numbers are in. At [S] equal to K_m the rate is exactly half of V_max, and at ten times K_m it is about 91 percent, a figure from our own calculation.
Turnover number
The maximum rate is the turnover number times the total enzyme concentration, V_max = k_cat × [E]₀ [1]. The turnover number k_cat is the limiting number of substrate molecules converted to product per enzyme molecule per unit of time, in reciprocal seconds [1]. Enter V_max and the enzyme concentration, with the same concentration unit, to get it. For example, V_max of 120 and an enzyme concentration of 0.4 give k_cat = 300 per time unit.
Catalytic efficiency
The ratio k_cat ÷ K_m is the specificity constant, also called the catalytic efficiency [1]. A higher value means a better enzyme at low substrate concentration. The page lists examples: chymotrypsin with K_m of 1.5 × 10⁻² M, k_cat of 0.14 per second and efficiency 9.3; carbonic anhydrase with K_m of 2.6 × 10⁻² M, k_cat of 4.0 × 10⁵ per second and efficiency 1.5 × 10⁷; and fumarase with 1.6 × 10⁸ per molar per second [1]. Enzymes working at the diffusion limit lie between 10⁸ and 10¹⁰ per molar per second [1].
Finding the substrate for a target rate
To get a chosen rate v, rearrange the equation to [S] = K_m v ÷ (V_max − v), which is our own algebra. With V_max of 100, K_m of 5 and a target of 90, the substrate needed is 45. The target must be below V_max, since no concentration of substrate can reach it. A target of 99 percent of V_max needs 99 times K_m.
Lineweaver–Burk line
Taking reciprocals gives the Lineweaver–Burk form, 1/v = 1/V_max + (K_m / V_max)(1/[S]), a straight line with a y-intercept of 1/V_max and an x-intercept of −1/K_m [2]. The calculator prints the line for your values. The page warns that all linearized forms should be avoided when estimating the kinetic parameters, and recommends nonlinear regression with proper weighting [2]. Use this line to understand the shape and not to fit data.
What K_m means
In the general scheme, K_m = (k₋₁ + k_cat) ÷ k₊₁, and under the equilibrium assumption it equals the dissociation constant k₋₁ ÷ k₊₁ [1]. A low K_m means that the enzyme reaches half of its maximum rate at a low substrate concentration. Compare K_m with the concentration of substrate in the cell to judge whether the enzyme is likely to be saturated.
Using the units
The calculator does not convert units. Enter V_max and the rate in the same unit, and K_m and [S] in the same concentration unit. For k_cat the enzyme concentration must be in the same concentration unit as V_max uses, and the answer is per the time unit of V_max. Convert minutes to seconds if you want to compare with tabulated values.
A worked comparison
Two enzymes can have the same V_max and quite different behaviour at low substrate. With V_max of 100 and a K_m of 5, the rate at a substrate concentration of 1 is 16.7. With a K_m of 50 it is only 1.96. The enzyme with the lower K_m is far better at picking up a scarce substrate, which is exactly what the catalytic efficiency measures. Try both sets of numbers in the calculator.
Practical tips
Measure initial rates, while less than about ten percent of the substrate has been used, so that the substrate concentration is still the one you started with. Use at least six substrate concentrations spanning about a tenth of K_m to ten times K_m, and repeat each, so that the curve is well defined at both ends.
Common mistakes
- Mixing concentration units. K_m and [S] must use the same unit.
- Using free enzyme for k_cat. Use the total enzyme concentration.
- Asking for a rate of V_max. The rate only approaches V_max.
- Fitting data with a double-reciprocal plot. Use nonlinear regression.
What next
Use this often? Add Michaelis-Me to your Home screen.
Frequently asked questions
What is a Michaelis-Menten calculator?
A tool that gives the rate of an enzyme reaction from V_max, K_m and the substrate concentration.
What is the Michaelis-Menten equation?
v = V_max [S] ÷ (K_m + [S]).
What does K_m mean?
The substrate concentration at which the reaction rate is half of V_max.
How do I find k_cat?
Divide V_max by the total enzyme concentration: k_cat = V_max ÷ [E]₀.
Should I use a Lineweaver–Burk plot to find K_m?
No. The page advises nonlinear regression instead of linearized forms.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.