This K factor calculator works out the K-factor, bend allowance, bend deduction and outside setback for bending sheet metal. Choose a K-factor from the rule-of-thumb table, enter your own, or work it out from a test bend, then enter the material thickness, inside bend radius and bend angle. The K factor calculator gives the numbers you need to work out a part's flat length.
How to use the K factor calculator
- Choose inches or millimeters.
- Choose how to get the K-factor: from the table (by bending method and material), your own value, or a measured bend allowance.
- Enter the thickness, inside radius and bend angle.
- Press Calculate.
What is the K-factor?
When sheet metal bends, the inside is compressed and the outside is stretched. Somewhere in between is the neutral axis, which keeps its length. Wikipedia defines the K-factor as the ratio of the neutral axis's distance from the inside face, t, to the material thickness, T: K = t ÷ T. It's typically between 0.3 and 0.5. The K-factor lets you work out how much material the bend uses.
Bend allowance and bend deduction
The bend allowance is the length of the neutral axis through the bend. Wikipedia gives:
BA = A × π ÷ 180 × (R + K × T)
where A is the bend angle in degrees and R is the inside bend radius. The bend deduction is the difference between the sum of the flange lengths, measured to the outside apex, and the flat length: BD = 2 × (R + T) × tan(A ÷ 2) − BA. The outside setback, the distance from the tangent point of the radius to the outside apex, is (R + T) × tan(A ÷ 2), so BD = 2 × OSSB − BA.
Rule-of-thumb K-factors
Wikipedia gives a rule-of-thumb table, noting that actual results may vary considerably:
| Method and radius | Soft | Medium | Hard |
|---|---|---|---|
| Air bending, R from 0 to T | 0.33 | 0.38 | 0.40 |
| Air bending, R from T to 3T | 0.40 | 0.43 | 0.45 |
| Bottoming, R from 0 to T | 0.42 | 0.44 | 0.46 |
| Bottoming, R from T to 3T | 0.46 | 0.47 | 0.48 |
| Coining, R from 0 to T | 0.38 | 0.41 | 0.44 |
| Coining, R from T to 3T | 0.44 | 0.46 | 0.47 |
| Any method, R over 3T | 0.50 | 0.50 | 0.50 |
Worked example
Wikipedia's example uses a 90° bend in material 10 mm thick with a 10 mm inside radius and a K-factor of 0.33: BA = 90 × π ÷ 180 × (10 + 0.33 × 10) = 20.89 mm. The outside setback is (10 + 10) × tan 45° = 20 mm, so the bend deduction is 2 × 20 − 20.89 = 19.11 mm. A flat blank for an L-bracket with two 50 mm flanges measured to the outside would be 100 − 19.11 = 80.89 mm long.
Working out K from a test bend
For accurate parts, bend a test strip with your own tooling, measure the bend allowance, and work K backwards: K = (BA ÷ (π × A ÷ 180) − R) ÷ T. Choose From a measured bend allowance and enter your measurement; using Wikipedia's example, a measured BA of 20.89 mm gives K = 0.33.
Reading the results
The big number is the K-factor used. The table shows the bend allowance, bend deduction, outside setback and the radius-to-thickness ratio, which decides the row of the table.
Flat length from flange lengths
To make a part from a flat blank, you need its flat length. If you measure each flange to the outside apex of the bend, the flat length is the sum of the flanges minus one bend deduction for each bend. If you measure each flange to the tangent point where the bend starts, the flat length is the sum of the flanges plus one bend allowance for each bend. Both give the same answer; use whichever matches how your drawing is dimensioned.
How radius and thickness affect K
The table shows that the K-factor rises as the bend radius gets larger compared with the thickness. With a tight bend, the inside is squeezed hard and the neutral axis moves toward the inside face, so K is lower, around 0.33 to 0.45. With a large radius, over three times the thickness, the material bends more evenly and the neutral axis sits near the middle, so K approaches 0.5. Harder materials also tend to have slightly higher K-factors than softer ones.
Bending methods
Wikipedia describes three common press brake methods. In air bending, the punch pushes the sheet into a V-shaped die without forcing it to the bottom, and the bend angle depends on how far the punch goes in. In bottoming, the sheet is pressed against the die. In coining, much higher force is used to stamp the bend, giving a tighter radius. Each method has its own row in the table.
Inches or millimeters
The K-factor has no unit, so it's the same whatever unit you use. Choose inches or millimeters to match your drawing, and the bend allowance, bend deduction and setback come out in that unit.
Common mistakes
- Using the outside radius. R is the inside bend radius.
- Confusing bend angle and included angle. A 90° bend leaves a 90° corner; a 120° bend leaves 60°.
- Mixing units. Enter T and R in the same unit.
- Trusting the table blindly. Test bends are more accurate.
Tips
- Record K-factors for each material and tool you use.
- Measure flanges to the outside apex for bend deduction.
- Check the first part before running a batch.
What next
Use this often? Add K Factor to your Home screen.
Frequently asked questions
How does a K factor calculator work?
It uses BA = A × π/180 × (R + K × T) and BD = 2(R + T)tan(A/2) − BA with a K-factor from the table, your own value or a test bend.
What is a typical K-factor?
Typically between 0.3 and 0.5, according to Wikipedia; 0.33 is common for soft material in air bending with a tight radius.
How do you calculate bend allowance?
BA = bend angle × π ÷ 180 × (inside radius + K × thickness).
What is bend deduction?
The difference between the flange lengths measured to the outside apex and the flat length: BD = 2 × OSSB − BA.
How do I find my own K-factor?
Bend a test piece, measure the bend allowance and use K = (BA ÷ (π × A/180) − R) ÷ T.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.