The Hazen-Williams calculator on this page finds the friction loss of water flowing through a pipe. Enter the flow, the inside diameter, the length and the pipe material, and it returns the head loss, the pressure drop and the water velocity. Use it to check whether a pipe run is big enough before you pick a pump.
How to use the Hazen-Williams calculator
- Choose US or Metric units.
- Pick the pipe material. Its typical C value is filled in for you.
- Enter the flow rate, the inside diameter of the pipe and the length of the run.
- Press Calculate. Read the head loss, the pressure drop, the loss per 100 units of length and the velocity.
To use your own roughness figure, type it in the C value box. A value you type overrides the material. Choose My own C value if the material you have is not on the list.
The Hazen-Williams formula
The Hazen-Williams equation is an empirical formula for the head loss of water in a full pipe. In SI units the head loss per unit of length is S = 10.67 × Q^1.852 ÷ (C^1.852 × d^4.8704), where Q is the flow in cubic metres per second, d is the inside diameter in metres and C is the roughness coefficient. [1] A US customary form gives the pressure drop in psi per foot of pipe as 4.52 × Q^1.852 ÷ (C^1.852 × d^4.8704), with the flow Q in gallons per minute and the diameter d in inches. [1]
The calculator uses the SI form and converts your inputs and results, so US and metric answers agree. Multiplying S by the length gives the head loss. We convert head to pressure with our own working: one foot of water head is about 0.4335 psi, and one metre is about 9.807 kPa.
Typical C values by pipe material
A higher C means a smoother pipe and less friction. The Wikipedia article lists these ranges. [1] Where a range is given, the calculator uses the middle of it, which is our own choice.
| Material | Listed C value | Used here |
|---|---|---|
| PVC | 150 | 150 |
| Polyethylene | 140 | 140 |
| Copper | 130 to 140 | 135 |
| Galvanized iron | 120 | 120 |
| Steel | 90 to 120 | 105 |
| Cast iron, new | 130 | 130 |
| Cast iron, 10 years | 107 to 113 | 110 |
| Cast iron, 20 years | 89 to 100 | 95 |
Worked example
Take 100 gallons per minute through 1,000 feet of 4-inch PVC pipe with C = 150. The calculator gives a head loss of about 5.76 ft, which is 0.576 ft per 100 ft, a pressure drop of about 2.50 psi and a velocity of about 2.55 ft/s. The US form of the equation with its constant of 4.52 gives about 2.49 psi, a difference that comes from the rounded constant. [1] The same pipe in metric units, 378.5 L/min through 101.6 mm pipe for 304.8 m, gives about 1.755 m of head loss and 17.2 kPa.
What the result tells you
- Head loss is the height of water the pump must make up to push the flow through the pipe. Add it to the static lift to get the total head a pump must deliver.
- Pressure drop is the same loss expressed as pressure, handy when you work in psi or kPa.
- Velocity shows how fast the water moves. Very high velocity means noise and wear, so a larger pipe may be better. A common rule of thumb keeps water speed under about 5 feet per second, but your project may differ.
- Loss per 100 units lets you scale the answer for a longer or shorter run.
Pipe size and flow trade-offs
The diameter is raised to the power 4.8704, so the pipe size has a very strong effect. Doubling the diameter cuts the head loss by a factor of about 29, while doubling the flow raises it by a factor of about 3.6. If a run loses too much head, a slightly bigger pipe is often the cheapest fix. A shorter run or fewer bends also help.
Using the result to pick a pump
Add the head loss to the vertical lift, then look for a pump that delivers your flow at that total head on its curve. If you are not sure of the lift, measure the height from the water surface to the highest point of the pipe. Fittings are best handled by adding their equivalent length to the pipe length before you calculate. Run the numbers for the longest path and for the highest flow you expect. If the velocity is high or the head loss takes a big share of the pump head, try the next pipe size up and compare. A few quick runs show you where extra money buys real savings and where it does not.
Limits of the Hazen-Williams calculator
- The equation is for water at ordinary temperatures in full, turbulent flow. It is not meant for other liquids, very hot water or very slow flow.
- The article warns that care is needed when using the US customary units. [1] This page converts for you, so you can enter plain gallons per minute and inches.
- Fittings, valves and sudden size changes add loss that this calculator does not include. Add an allowance for them, for example as extra equivalent length.
- The C value of an old pipe can be lower than the table, because scale and roughness build up over the years.
- Always use the inside diameter. A nominal pipe size is often not the same as the true bore.
This is a planning estimate. For design work with safety or code requirements, such as fire protection or a public water system, have a qualified engineer check the numbers and follow the local rules.
What next
Use this often? Add Hazen-Willia to your Home screen.
Frequently asked questions
What does a Hazen-Williams calculator do?
It estimates the friction loss of water flowing through a full pipe from the flow rate, the inside diameter, the pipe length and the roughness coefficient C. It gives the head loss, pressure drop and velocity.
What C value should I use for PVC pipe?
The Wikipedia table gives C = 150 for PVC, so the calculator uses 150. You can type another C value to override the material.
Does the Hazen-Williams calculator include fittings?
No. It covers straight pipe only. Elbows, valves and size changes add loss, so add an allowance such as extra equivalent length to the pipe length.
Can I use the Hazen-Williams equation for oil or hot water?
No. The equation was made for water at ordinary temperatures in full pipes. Other liquids and very hot water need a different method.
Why is the answer a little different from the US formula?
The calculator uses the SI form and converts units. The US form uses a rounded constant of 4.52, so the two can differ by a fraction of a percent.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.