Use this duct size calculator to find the round duct diameter for your airflow from a friction rate or an air velocity, and the equivalent rectangular duct, using the Darcy–Weisbach equation.

Restored your last values ·

Enter the airflow and either a friction rate or an air velocity. You get the round duct diameter, the air speed, the friction loss and the area, and the other side of a rectangular duct if you enter one side.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the airflow and the friction rate or velocity, then press Calculate.

See full result

This duct size calculator finds the diameter of a round duct for a given airflow and either a friction rate or an air speed. It also gives the matching rectangular duct when you enter one side. Enter the airflow in cubic feet per minute (CFM) or litres per second, choose the design method and the duct surface, and read the diameter, the air speed, the friction loss and the cross-section area. The pressure loss comes from the Darcy–Weisbach equation [1] with an explicit friction factor [2].

How to use the duct size calculator

  1. Choose US (CFM, inches) or Metric (L/s, millimetres).
  2. Choose the design method: friction rate, or air velocity.
  3. Choose the duct surface: galvanised steel, smooth plastic or flexible duct.
  4. Enter the airflow.
  5. Enter the friction rate (inches of water per 100 feet, or pascals per metre) or the air velocity (feet per minute or metres per second).
  6. Optionally enter one side of a rectangular duct to get the other side, then press Calculate.

The method: equal friction

In the friction rate method you choose how much pressure the air may lose per unit length, and the tool finds the round duct that carries your airflow at that loss. This is the equal friction method, a common way to size the branches of a supply system. In the velocity method you choose the air speed, and the diameter follows from the area needed: area = airflow ÷ velocity.

The formulas

  • Pressure loss per length = f × (ρ ÷ 2) × v² ÷ D, where f is the friction factor, ρ the air density, v the mean velocity and D the hydraulic diameter [1].
  • For a round duct D is its diameter. Otherwise D = 4 × area ÷ perimeter, and for a closed rectangular duct that is 2ab ÷ (a + b) [3].
  • The friction factor f is 0.25 ÷ [log10(roughness ÷ D ÷ 3.7 + 5.74 ÷ Re^0.9)]², an explicit approximation of the Colebrook–White equation, valid for Reynolds numbers from 5,000 to 100 million [2].
  • Air density is 1.2041 kg per cubic metre at 20 °C and 101.325 kPa [4]. We use that value throughout.

The viscosity of air at 20 °C, about 18 micropascal seconds, comes from a published empirical fit and is part of our own working. The roughness values are also our own working assumptions: 0.15 mm for galvanised steel, 0.01 mm for smooth plastic and 0.9 mm for flexible duct. Real ducts differ, so treat them as typical values.

Equivalent rectangular duct

For a rectangular duct, the tool keeps your side fixed and searches for the other side so that the same airflow produces the same friction loss as the round duct. It uses the hydraulic diameter of the rectangle in the same pressure-loss formula. This is an exact match of friction, our own working, and it gives a result close to the widely used equivalent-diameter tables.

Worked example

Size a round galvanised duct for 400 CFM at a friction rate of 0.10 inch of water per 100 feet. The calculator gives a diameter of 9.77 inches, an air speed of about 768 feet per minute and a cross-section area of 75 square inches.

If you wanted to run the same airflow in a rectangular duct 8 inches deep, the other side is 9.84 inches, with a hydraulic diameter of 8.83 inches. In the velocity method, 400 CFM at 700 feet per minute needs a 10.24 inch round duct, which loses about 0.079 inch of water per 100 feet.

AirflowFriction rateRound ductAir speed
100 CFM0.08 in. w.g. per 100 ft6.10 in493 fpm
400 CFM0.10 in. w.g. per 100 ft9.77 in768 fpm
1,000 CFM0.08 in. w.g. per 100 ft14.42 in882 fpm
200 L/s0.8 Pa per m254.7 mm3.93 m/s

Choosing a friction rate or velocity

Designers commonly choose a friction rate of about 0.08 to 0.10 inch of water per 100 feet for residential supply ducts, and keep air speeds lower in branches to limit noise. These are common rules of thumb, not standards cited here. Lower friction means larger and costlier ducts but a quieter, more efficient system. Higher friction saves metal and space but needs a stronger fan and can be noisy.

What this tool leaves out

  • Fittings. Elbows, tees, dampers, registers and filters add pressure loss that straight-duct friction does not count.
  • Leakage and insulation. They change the airflow reaching each room.
  • Temperature and altitude. The tool assumes air at 20 °C and sea level density.
  • Equipment limits. Your fan or furnace has a fixed available pressure.
  • Load calculations. This tool sizes ducts for a flow you already know. It does not tell you how much airflow a room needs.

This is a planning estimate. For a real installation follow the design method required by your local code and have the system designed by a qualified HVAC professional.

Common mistakes

  • Mixing the units. In US mode the friction rate is in inches of water per 100 feet. In Metric mode it is in pascals per metre.
  • Entering a friction rate for the velocity method, or the other way round. Check which method is selected.
  • Using the diameter as the side of a square duct. A square duct with the same area is smaller in hydraulic diameter and loses more.
  • Forgetting that flexible duct has much higher friction, so it needs a larger diameter.

What next

Use this often? Add Duct Size to your Home screen.

Frequently asked questions

How does a duct size calculator work?

It uses the Darcy–Weisbach equation with an explicit friction factor to find the round duct diameter that carries your airflow at the friction rate or velocity you choose.

What size duct do I need for 400 CFM?

At 0.10 inch of water per 100 feet in galvanised steel the round duct is about 9.77 inches, with air moving at about 768 feet per minute.

How do I find a rectangular duct equivalent?

Enter one side of the rectangle. The tool finds the other side that gives the same friction at the same airflow as the round duct.

What friction rate should I use?

A common rule of thumb for residential supply ducts is about 0.08 to 0.10 inch of water per 100 feet. Your design method or local code may set a different value.

Does it include elbows and fittings?

No. Fittings add pressure loss that straight-duct friction does not include, so allow for them separately.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.