This air changes per hour calculator works out how many times the air in a room is replaced each hour, from the room's size and the airflow of a fan, ventilation system or air purifier. You can also work backwards: enter a target number of air changes, and the air changes per hour calculator tells you the airflow you need.
How to use the air changes per hour calculator
- Choose US or metric units. US (feet and cubic feet per minute) is the default.
- Choose what to work out: air changes per hour, or the airflow needed.
- Enter the room's length, width and ceiling height.
- Enter the airflow (or your target air changes per hour), then press Calculate.
What are air changes per hour?
Air changes per hour (ACH) measure how much air flows into or out of a room in an hour, compared with the room's volume. According to the Wikipedia article on air changes per hour, if a volume of air equal to the room's volume flows through it in one hour, that's one air change per hour. A higher number means more ventilation, and more of the room's air being replaced with fresh or cleaned air.
The ACH formula
In US units, with airflow Q in cubic feet per minute (CFM) and room volume V in cubic feet:
ACH = 60 × Q ÷ V
The 60 turns minutes into hours. In metric, airflow is usually given in cubic meters per hour, so ACH is simply the airflow divided by the volume: ACH = Q (m³/h) ÷ V (m³). The room's volume is its length × width × height. To find the airflow you need for a target, the calculator turns the formula around: Q = ACH × V ÷ 60 in CFM, or ACH × V in m³/h.
How many air changes do you need?
The Wikipedia article notes that the CDC suggests aiming for at least 5 air changes per hour of clean air, where feasible, to help reduce airborne virus particles indoors. It's a target to aim for rather than a universal requirement. The article also explains that ACH is seldom the actual basis for designing home ventilation: residential ventilation rates are usually based on floor area and the number of occupants, while some standards, such as those for hospitals, do use air changes. Homes with mechanical ventilation are often rated at 3 to 5 ACH. For air purifiers, the article describes an equivalent ACH: the purifier's clean air delivery rate (CADR) divided by the room volume.
Worked example
Take a room 12 feet long, 12 feet wide, with an 8-foot ceiling. Its volume is 12 × 12 × 8 = 1,152 cubic feet. With an air purifier or fan moving 200 CFM, ACH = 60 × 200 ÷ 1,152 = 10.4 air changes per hour, so a room's volume of air moves through about every 5.8 minutes. To reach the CDC's aim of 5 ACH in the same room, you'd need 5 × 1,152 ÷ 60 = 96 CFM.
In metric, a room 4 m by 4 m with a 2.5 m ceiling holds 40 m³. An airflow of 300 m³/h gives 300 ÷ 40 = 7.5 air changes per hour.
Reading the results
When you work out ACH, the big number is the air changes per hour, and the table shows the room volume, the time it takes to move one room's worth of air, and whether the result meets the CDC's aim of 5 ACH. When you work out airflow, the big number is the airflow needed in CFM or m³/h, with the room volume below.
What the number assumes
The calculation assumes the incoming air mixes evenly through the room. In practice, a purifier in a corner or a vent near a door may clean some parts of a room better than others, so the real mixing can be less even. The rated airflow of a fan or purifier is also often measured at its highest setting, which may be louder than you'd want to run all day. Use the setting you actually use when you enter the airflow.
Ventilation per person
The Wikipedia article also shows how air changes relate to ventilation per person. In US units, the airflow per person in cubic feet per minute equals the ACH times the floor area per person in square feet times the ceiling height in feet, divided by 60. So a room with 10 ACH, 100 square feet per person and an 8-foot ceiling gives each person about 133 CFM of air. That's a useful way to think about a shared office or classroom, where the number of people matters as much as the room size.
Improving air changes
There are two ways to raise the number: bring in more outdoor air, for example by opening windows or running exhaust and supply fans, or clean the air already in the room with a filter or purifier. Both count toward clean air changes. To compare purifiers, divide each one's clean air delivery rate by your room volume to see how many air changes it would add.
Common mistakes
- Using floor area instead of volume. Multiply by the ceiling height too.
- Mixing minutes and hours. CFM is per minute; the formula multiplies by 60.
- Using the highest fan setting. Enter the airflow you actually run.
- Counting recirculated air. Only outdoor or filtered air counts toward clean air changes.
Tips
- Check the CADR or CFM on your purifier's label.
- Combine ventilation and filtration to raise air changes.
- For larger rooms, use more than one purifier.
What next
Use this often? Add Air Changes to your Home screen.
Frequently asked questions
How does an air changes per hour calculator work?
It divides the airflow by the room volume: ACH = 60 × CFM ÷ cubic feet, or m³/h ÷ m³.
How many air changes per hour do I need?
The CDC suggests aiming for at least 5 ACH of clean air where feasible to reduce airborne virus particles.
How do I calculate CFM for a room?
CFM = target ACH × room volume in cubic feet ÷ 60. For 5 ACH in a 1,152 ft³ room, that's 96 CFM.
What is equivalent ACH for an air purifier?
The purifier's clean air delivery rate divided by the room volume.
How do I find a room's volume?
Multiply the length, width and ceiling height.
Sources
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.