Saved

Press the star next to a tool's name to save it.

All my tools

Water TDS Calculator (Total Dissolved Solids)

Use this water tds calculator to turn a conductivity reading in µS/cm into total dissolved solids in mg/L and ppm, or the reverse, and compare it with the WHO taste bands and the EPA 500 mg/L guideline.

Restored your last values ·

Choose whether to find TDS from a conductivity reading or the conductivity from a TDS value. Enter the number and, if you know it, the conversion factor k. Blank uses 0.67. You get mg/L and ppm, the taste class and the 500 mg/L US EPA guideline.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the conductivity or the TDS, then press Calculate.

See full result

A water tds calculator turns an electrical conductivity reading into total dissolved solids, in mg/L and parts per million, or works back from a TDS value to the conductivity. It then places the answer against the taste bands quoted from the World Health Organization and the 500 mg/L secondary guideline of the US EPA.

How to use the water tds calculator

  1. Choose TDS from EC or EC from TDS.
  2. Enter the reading, in the unit chosen.
  3. Leave the factor blank, or enter your own.
  4. Press Calculate.

What TDS means

Total dissolved solids are everything dissolved in water that passes through a filter: salts such as calcium, magnesium, sodium, chloride, sulphate and bicarbonate, and small amounts of other matter. The Wikipedia article on the topic notes that TDS is often measured in parts per million and gives one part per million as one milligram of dissolved solids per 1,000 grams of water [3]. A hand-held TDS meter does not weigh the solids. It measures conductivity and applies a factor.

The conversion formula

TDS in mg/L is a factor, called ke, multiplied by the electrical conductivity in µS/cm at 25 °C. Wikipedia says that the conversion factor ke varies between 0.55 and 0.8 [3]. This calculator uses 0.67, a mid-range planning figure of our own, until you enter your own factor, and works the other way, EC equals TDS divided by k.

Why the factor varies

Conductivity only sees ions that carry current, and each ion carries it differently. Water rich in sodium chloride behaves differently from water rich in calcium bicarbonate, so one factor cannot fit every source. If you have a laboratory TDS and a conductivity reading for the same water, divide one by the other to find your own factor. A factor from your own source will beat any general default.

A worked example

Take a reading of 500 µS/cm and the default factor of 0.67. TDS is 0.67 × 500 = 335 mg/L, which is about 335 ppm. This is our own working. At the ends of the quoted range, 0.55 and 0.8, the same reading gives 275 and 400 mg/L. That spread of nearly 50 percent is the honest uncertainty of any conductivity-based figure.

Units: µS/cm, mS/cm, mg/L and ppm

One millisiemens per centimetre is 1,000 microsiemens per centimetre, so a reading of 0.5 mS/cm is 500 µS/cm. The calculator accepts either unit for the reading. Wikipedia defines one part per million as 1 mg of dissolved solids per 1,000 g of water [3], and a litre of dilute water weighs about 1,000 g, so the same number is shown in both units. Readings should be at 25 °C, because conductivity rises with temperature. Many meters correct for this automatically.

The WHO taste bands

The Australian drinking-water guidelines, which quote the WHO, rate taste by TDS level: up to 600 mg/L is good, 600 to 900 is fair, 900 to 1,200 is poor and above 1,200 is unacceptable [1]. The same page says that no specific health guideline value is provided for TDS, and that for good palatability TDS should not exceed 600 mg/L [1]. It also states that water with very high or very low TDS may be corrosive [1].

The US EPA guideline

The US EPA lists a secondary maximum contaminant level of 500 mg/L for TDS. Its page says that the agency does not enforce these levels, that they are guidelines for aesthetic considerations, and that these substances are not considered a risk to human health at that level [2]. Above 500 mg/L the page lists hardness, deposits, coloured water, staining and a salty taste [2]. The calculator tells you whether your result is above or below 500 mg/L.

Fresh, brackish and saline water

Wikipedia classes water by TDS: fresh water is under 1,000 ppm, brackish water 1,000 to 10,000 ppm, saline water 10,000 to 35,000 ppm and hypersaline water above 35,000 ppm [3]. We treat ppm and mg/L as the same figure. The calculator prints the class beside the result. A reading in the brackish range is a sign that the water suits neither drinking nor many garden uses without treatment.

What a low reading means

A low TDS is not automatically better. Very low values can taste flat, and the Australian guidance notes that very low TDS water may also be corrosive [1]. Treated water from a reverse osmosis unit, rainwater and distilled water all read low. Use the reading to check a filter, to compare sources and to track changes over time, not to judge purity.

When to use a laboratory

A conductivity reading cannot tell you what is dissolved. It does not detect lead, nitrate, bacteria, pesticides or arsenic, and some of those are dangerous at tiny concentrations. The EPA and WHO figures above concern taste and scale, not safety. If you are concerned about a well or a tap, send a sample to an accredited laboratory and follow its advice.

Common mistakes

  • Using a reading taken at the wrong temperature. Conductivity is quoted at 25 °C.
  • Treating the default factor as exact. It can be well out.
  • Reading a low TDS as a safety check. It says nothing about germs or poisons.
  • Mixing µS/cm and mS/cm. 1 mS/cm is 1,000 µS/cm.

What next

Use this often? Add Water TDS Ca to your Home screen.

Frequently asked questions

What is a water tds calculator?

A tool that converts an electrical conductivity reading into total dissolved solids, in mg/L and ppm, or back again.

What conversion factor should I use?

Wikipedia gives a range of 0.55 to 0.8. This tool uses 0.67, a mid-range planning figure, by default.

Is mg/L the same as ppm for TDS?

For water, yes. The two give the same number.

What is a good TDS for drinking water?

The WHO taste bands quoted by NHMRC rate up to 600 mg/L as good. The US EPA guideline is 500 mg/L. Both are about taste, not health.

Can a TDS reading show that water is safe?

No. It does not detect germs or most harmful chemicals. Use a laboratory test.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Physics & Science Tools