Saved

Press the star next to a tool's name to save it.

All my tools

Pcb Trace Resistance Calculator

Use this PCB trace resistance calculator to find the resistance of a copper track from its width, length and copper weight, with the voltage drop and power loss at a current.

Restored your last values ·

oz/ft²
A

Choose US or metric units. Enter the width and length of the trace and the copper weight. You get the resistance at 25 °C and at the temperature you give. Add a current to see the voltage drop and the power lost in the trace.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose the units, enter the trace width, the copper weight and the length, then press Calculate. Add a temperature and a current for more.

See full result

A PCB trace resistance calculator finds the resistance of a copper track from its width, length and copper weight. Enter the dimensions and the trace temperature, and the tool gives the resistance in milliohms. Add a current and it also gives the voltage drop and the power lost as heat along the track.

How to use the pcb trace resistance calculator

  1. Choose US or metric units.
  2. Enter the width, the copper weight and the length of the trace.
  3. Add the trace temperature if it is not 25 °C.
  4. Add a current to see the voltage drop and power.
  5. Press Calculate.

The resistance formula

The resistance of a track is R = ρ × L ÷ A′ × (1 + α × (T − 25)), where ρ is the resistivity of copper, L the length, A′ the cross-section and α the temperature coefficient. The resistance of a uniform bar is its resistivity times its length divided by its cross-section, and the linear temperature correction ρ(T) = ρ0[1 + α(T − T0)] is given in Wikipedia's article on electrical resistivity [1]. Taking 25 °C as the reference temperature and working in centimetres and square centimetres is our own choice.

The constants

The tool uses a resistivity of 1.7 × 10⁻⁶ ohm cm, the value that NextPCB uses in its guide [2]. Wikipedia gives the resistivity of copper as 16.78 nano-ohm metres at 20 °C, which is 1.678 × 10⁻⁶ ohm cm [3]. The tool's figure is about 1.3 percent higher. The temperature coefficient is 0.0039 per °C. Wikipedia lists 3.93 × 10⁻³ per kelvin for annealed copper and 4.04 × 10⁻³ for copper in general [1], so 0.0039 is a rounded value close to the annealed figure.

The cross-section

The area is the width times the thickness. One ounce of copper per square foot is 1.378 mil thick, or 0.0035 cm, the conversion that NextPCB gives [2]. For a 53.82 mil trace of 1 oz copper the area is 4.785 × 10⁻⁴ cm², or 0.04785 mm². In metric mode the width is converted to mil by dividing by 0.0254, so a 1.367 mm trace gives the same area.

A worked example

Take a 53.82 mil trace of 1 oz copper that is 60 mm long. At 25 °C its resistance is 21.32 milliohm. At 35 °C, the temperature factor is 1.039 and the resistance rises to 22.15 milliohm. With 3 A, the drop is 66.45 mV and the power lost is 0.199 W. NextPCB's own example for a 60 mm trace also reports about 22 milliohm [2].

Which temperature to use

Some guides apply the correction at the ambient temperature. We use the temperature of the trace, because the resistivity formula depends on the temperature of the copper itself [1]. If the trace is warm because of the current, enter the ambient plus the rise. Leave the box blank for 25 °C, where the factor is exactly 1. In US mode the box is in °F.

Voltage drop and power

The drop along the trace is the current times the resistance, V = I × R, which is Ohm's law [5]. The power lost is I² × R, which is our own working from the same relation. They matter for long or thin tracks that feed a load: 66 mV may be harmless on a 5 V rail, but it is a larger share of a 1.8 V supply. The power shows how much heat the trace itself makes.

Units and conversions

In US mode the width is in mil and the length in inches, and the tool converts the length at 25.4 millimetres to the inch. In metric mode both are in millimetres. The result shows the length in both units, and the area in cm² and mm², so you can check the conversion. Copper weight is in ounces per square foot in both modes, as boards are specified that way.

Copper thickness

The thickness changes the resistance in inverse proportion. Half-ounce copper has twice the resistance of one-ounce copper for the same width and length, and two-ounce copper has half. The tool uses 1.378 mil for each ounce [2]. Wikipedia gives 34.1 micrometres, or 1.34 mil, for 1 oz per square foot [4], about 3 percent less. If your board maker quotes a different finished thickness, you can enter the equivalent weight in ounces instead.

Using the result

A trace that is only a few milliohms is rarely a problem for a signal, but it matters on a power path. Compare the drop with the tolerance of the supply it feeds, and the power with the heat the trace can shed. If the drop is too large, widen the trace, shorten it, use thicker copper or add a parallel track or a plane. Then run the calculation again with the new numbers to confirm the improvement.

What the estimate leaves out

The tool treats a trace as a straight bar of uniform width and thickness. It leaves out the resistance of vias, pads and corners, the effect of plating, the skin effect at high frequency, and manufacturing tolerances on the width and the copper thickness. None of these corrections is in the formula we use. For a precise figure on a critical net, use a field solver or measure a test coupon.

Common mistakes

  • Mixing mil and millimetres. Check the units box before entering the width.
  • Using the ambient temperature as the trace temperature. The copper is warmer than the air when it carries current.
  • Forgetting the copper weight. Half-ounce copper doubles the resistance.
  • Ignoring the vias. Each via adds resistance that this tool does not include.

What next

Use this often? Add Pcb Trace Re to your Home screen.

Frequently asked questions

What is a PCB trace resistance calculator?

A tool that finds the resistance of a copper track from its width, length, copper weight and temperature, with the voltage drop and power loss at a current.

What is the formula for trace resistance?

R equals the resistivity times the length divided by the cross-section, times one plus 0.0039 times the temperature minus 25 °C.

What resistivity does the tool use for copper?

1.7 × 10⁻⁶ ohm cm. Wikipedia gives 1.678 × 10⁻⁶ ohm cm at 20 °C, about 1.3 percent lower.

How much resistance does a 60 mm trace have?

A 53.82 mil trace of 1 oz copper that is 60 mm long has about 21.3 milliohm at 25 °C and 22.2 milliohm at 35 °C.

Does the tool include vias and plating?

No. It treats the trace as a straight bar of uniform width and thickness, and leaves out vias, corners and plating.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Physics & Science Tools