Saved

Press the star next to a tool's name to save it.

All my tools

Mixed Air Calculator

Use this mixed air calculator to find the temperature of outdoor and return air after blending, or the outdoor air percentage from the three temperatures, in °F or °C.

Restored your last values ·

Choose to find the mixed air temperature from the two flows and temperatures, or the outdoor air percentage from the three temperatures. Use the same flow unit for both streams.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose what to find, fill in the boxes, then press Calculate.

See full result

A mixed air calculator finds the temperature of air after an outdoor stream and a return stream blend, as in an air handler. It also works backwards: from the outdoor, return and mixed temperatures it gives the share of outdoor air. That makes it a mixed air temperature calculator and a quick outdoor air percentage check in one.

How to use the mixed air calculator

  1. Choose US or metric.
  2. Choose whether to find the mixed temperature or the outdoor air percentage.
  3. Enter the flows and temperatures.
  4. Press Calculate.

What mixed air is

In an air handling unit, return air from the building meets outdoor air at the mixing box before it reaches the coil. The temperature after they blend is the mixed air temperature. It is a flow-weighted average of the two streams. It matters because it sets the load on the heating or cooling coil, and because it lets a technician check how much outdoor air the system is really taking in, with nothing more than a thermometer.

The mixed temperature formula

With an outdoor flow Q₁ at T₁ and a return flow Q₂ at T₂, the calculator uses T mix = (Q₁T₁ + Q₂T₂) ÷ (Q₁ + Q₂). This is our own working, from the energy balance of two streams that have the same density and specific heat. In a mixing chamber, dampers set the proportions of return, outside and exhaust air, and mixing the right amount of cooler outside air with warmer return air can help reach the desired supply temperature [2]. The simple form is the dry-bulb special case, and it is the one used for quick checks.

A worked example

Take 1,000 cfm of outdoor air at 95 °F and 3,000 cfm of return air at 75 °F. The total is 4,000 cfm, and T mix = (1,000 × 95 + 3,000 × 75) ÷ 4,000 = 80 °F. The outdoor share is 25%. The flows can be in any unit, since only their ratio matters; the numbers are our own example. The calculator shows the sums in its working line so that you can follow each step.

Finding the outdoor air percentage

Switch to the percentage mode to work back from measured temperatures. A trade article gives the rule as fresh air % = (mixed − return) ÷ (outdoor − return) × 100 [1]. Its example has an outdoor air temperature of 100 °F, a return air temperature of 75 °F and a mixed air temperature of 80 °F, which gives 5 ÷ 25 = 20% [1]. The calculator reproduces this, and it returns the same number whatever the temperature unit, since only differences enter.

From percentage to flow

If you enter the total supply air flow, the calculator multiplies it by the percentage to give the outdoor air flow, and gives the rest as return air. The article does the same: 20% of 1,200 cfm is 240 cfm of outside air [1]. This is the way a technician checks whether a minimum outdoor air flow is being met without a flow hood, though the method is only as good as the temperature readings.

How to measure the temperatures

The trade article stresses where to measure. The mixed temperature should be taken after the outdoor air has blended with the return air, such as in the return plenum or the blower compartment [1]. The return temperature at the equipment can differ from that at the grille because of gains or losses in the duct [1]. Take several readings across the duct if the air is stratified, and average them, since a single point may sit in a cold or warm streak.

When the method fails

When the outdoor and return temperatures are almost the same, the denominator of the percentage formula is close to zero, and a small reading error causes a large error in the answer; the calculator refuses to divide when they are equal. The method works best when the difference is at least 15 to 20 degrees, which is our own rule of thumb. A mixed temperature outside the range between the other two is also rejected, since it cannot come from blending.

Why humidity and density matter

The simple average assumes the two streams have the same density and specific heat. In reality, warm moist air is lighter than cool air, and moisture carries energy. A full psychrometric calculation works with humidity ratio and enthalpy, so it can give a mixed temperature that differs a little from the dry-bulb average. For design work, use measured values with a psychrometric chart or software.

Using the result

Once you know the mixed air temperature, you can estimate the coil load or compare it with the setpoint of an economizer control. You can also see the effect of changing the outdoor air share: a higher share moves the mixed temperature toward the outdoor value. Try a few shares to see the trend. For design or commissioning, use measured flows and a full psychrometric calculation, with a heating and cooling professional to check the figures.

Common mistakes

  • Measuring the mixed temperature too early. Read it where the streams have blended.
  • Using different flow units for the two streams. Both flows must use the same unit.
  • Trusting the percentage when the temperatures are close. The answer becomes unreliable.
  • Ignoring humidity. The dry-bulb average does not mix moisture.
  • Using grille temperature as the return temperature. Duct losses can change it.

What next

Use this often? Add Mixed Air to your Home screen.

Frequently asked questions

What is a mixed air calculator?

A tool that finds the temperature of an outdoor air stream and a return air stream after they blend.

What is the mixed air temperature formula?

T mix = (outdoor flow × outdoor temperature + return flow × return temperature) ÷ total flow.

How do you find the outdoor air percentage from temperatures?

(Mixed − return) ÷ (outdoor − return) × 100, with all three in the same unit.

Why is the mixed air temperature calculator only an estimate?

It ignores humidity and air density, so a full psychrometric calculation gives a slightly different value.

Can I use any flow unit?

Yes, such as cfm or litres per second, if both streams use the same unit.

What if the outdoor and return temperatures are the same?

The percentage cannot be found, and the calculator asks for different values.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Everyday Life Tools