Saved

Press the star next to a tool's name to save it.

All my tools

Mini-Split Size Calculator

Use this mini-split size calculator to estimate the cooling capacity in BTU per hour, tons and kilowatts for one room, using the ENERGY STAR sizing chart and its sun, shade, occupant and kitchen adjustments.

Restored your last values ·

Enter the floor area of the room, the sun or shade, the number of regular users and whether it is a kitchen. Blank people means two.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the room area, set the options and press Calculate.

See full result

A mini-split size calculator helps you choose the cooling capacity, in BTU per hour, for a ductless unit that serves one room. This one uses the ENERGY STAR room air conditioner sizing chart and its published adjustments for shade, sun, extra people and kitchens. [1] It then shows the answer in tons and kilowatts and points to the next common unit size.

How to use this mini-split size calculator

  1. Pick US or metric units and enter the floor area the unit must cool.
  2. Choose heavy shade, normal or very sunny for the room.
  3. Enter how many people regularly use the room. Leave it blank for two.
  4. Say whether it is a kitchen and press Calculate.

The ENERGY STAR sizing chart

The chart matches the area to be cooled with the capacity needed. [1] It assumes an 8-foot ceiling. The calculator finds your row and starts from that figure.

Area (sq ft)BTU per hour
100 up to 1505,000
150 up to 2506,000
250 up to 3007,000
300 up to 3508,000
350 up to 4009,000
400 up to 45010,000
450 up to 55012,000
550 up to 70014,000
700 up to 1,00018,000
1,000 up to 1,20021,000
1,200 up to 1,40023,000
1,400 up to 1,50024,000
1,500 up to 2,00030,000
2,000 up to 2,50034,000

The adjustments

  • Heavy shade: reduce the capacity by 10 percent. [1]
  • Very sunny room: increase the capacity by 10 percent. [1]
  • More than two regular occupants: add 600 BTU per hour for each extra person. [1]
  • Kitchen: add 4,000 BTU per hour. [1]

ENERGY STAR does not say in which order to apply them. Our own working applies the shade or sun percentage to the chart value first, then adds the people and kitchen amounts.

Worked example

A kitchen of 500 square feet is very sunny and four people use it. The chart gives 12,000 BTU per hour for 450 up to 550 square feet. Very sunny adds 10 percent, so 13,200. Two extra people add 1,200, making 14,400. The kitchen adds 4,000, so the total is 18,400 BTU per hour. That is about 1.53 tons or 5.39 kilowatts of cooling. The next common size up is 24,000 BTU per hour.

BTU, tons and kilowatts

One ton of refrigeration is exactly 12,000 BTU per hour, or about 3.517 kilowatts. [2] That is why a 12,000 BTU unit is called a one-ton unit. The calculator divides your total by 12,000 for tons and multiplies by 3.516853 over 12,000 for kilowatts. These are cooling capacities, not the electricity the unit draws, which is much lower for an efficient inverter machine.

Picking an actual model

Manufacturers sell units in steps, and common mini-split sizes are around 9,000, 12,000, 18,000, 24,000 and 36,000 BTU per hour. This list is a common rule of thumb rather than a standard, so check the range of the brand you like. The calculator names the first size that covers your total. Because inverter units can run below full power, a unit slightly above your number is normally fine. A unit far too large cycles on and off, cools unevenly and removes less moisture.

Why the chart is a starting point

The chart is built for a standard room. Real rooms differ. A bedroom with one small window on a shaded side needs less cooling than the same area facing west with large glass. That is why the guide lets you move the figure up or down by 10 percent for sun and shade, and why we show both the chart value and the adjusted total. If you are between two sizes, think about how you use the room. A bedroom used at night may be happy with the smaller unit, while a home office with computers may want the larger one.

How to read the results

  • Chart capacity for the area is the unadjusted figure from the table.
  • Adjusted capacity includes shade or sun, extra people and the kitchen allowance.
  • Tons and kilowatts are the same capacity in other units, handy when you compare brands.
  • The next common unit size is the first size on a common list that covers your total.

Heating

Many mini-splits also heat. The chart here is for cooling only. Heating needs depend on your climate and insulation, and the heating rating of a unit changes with outdoor temperature. Use the maker's tables or an installer's heat-loss calculation to size for winter.

Multi-zone systems

If one outdoor unit serves several rooms, work out each room separately and ask the installer to size the outdoor unit for the combination. Rooms are rarely all at peak load together, so the outdoor unit may be smaller than the sum.

Limits of the estimate

This is a planning estimate for a single room. The chart assumes an 8-foot ceiling, and the guide suggests thinking about airflow for higher ceilings. It does not account for poor insulation, large west-facing windows, a top-floor room under a dark roof, or equipment that gives off heat. For a whole home, or when you are buying a system, ask a licensed HVAC contractor for a proper load calculation.

Common mistakes

  • Using the area of the whole home for a one-room unit.
  • Counting every person who ever visits instead of the regular users.
  • Forgetting the kitchen allowance in an open-plan space with a cooktop.
  • Reading tons as weight. It is a unit of cooling.
  • Picking a unit much bigger than needed because bigger sounds safer.

What next

Use this often? Add Mini-Split S to your Home screen.

Frequently asked questions

What size mini-split do I need for 500 square feet?

The ENERGY STAR chart gives 12,000 BTU per hour for 450 up to 550 square feet. Sun, extra people and a kitchen raise that. Use this mini-split size calculator for your exact case.

How many BTU equal one ton?

One ton of refrigeration is exactly 12,000 BTU per hour, or about 3.517 kilowatts.

How does the mini-split size calculator treat a kitchen?

It adds 4,000 BTU per hour, the amount the ENERGY STAR guide gives for a kitchen.

Does this size the heating as well?

No. It sizes cooling only. Heating depends on climate and insulation, so use the maker tables or an installer.

Is a bigger mini-split always better?

No. A unit far above the need cycles on and off, cools unevenly and removes less moisture.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.