A kVA calculator works out the apparent power of an electrical supply from its voltage and current, and converts between kVA, kW and amps for single-phase and three-phase systems. It also covers a kVA to amperage calculator, a three phase calculator and a transformer sizing calculator. Enter the values, choose what to find and press Calculate.
How to use the kVA calculator
- Choose the supply: single-phase or three-phase.
- Choose what to find.
- Enter the voltage and the other values that are asked for.
- Add a power factor to also get kW and kvar, then press Calculate.
What kVA measures
The kVA is the apparent power of a supply, the product of the RMS voltage and the RMS current [1], divided by 1,000. The volt-ampere rating is most used for generators and transformers [2]. Because the rating is just the product of voltage and current, it does not depend on whether the load is resistive or inductive. The kW, the real power, depends on the load as well.
Single-phase formula
For a single-phase supply, the apparent power is S = I × V ÷ 1,000, where I is the current in amperes, V is the voltage in volts and S is in kVA [1]. For example, a 240 volt supply at 10 amperes gives 2.4 kVA. Choose single-phase and the first option, and the calculator returns exactly that. No extra factor is used for single-phase.
Three-phase line-to-line
For a three-phase supply with the line-to-line voltage, the formula is S = √3 × I × V ÷ 1,000. This is our own working from the relation that the line-to-line voltage is √3 times the line-to-neutral voltage [3]. For example, 10 amperes at 240 volts gives 4.157 kVA. The √3 factor, about 1.732, is used for the line-to-line voltage only. The line voltage is the one you measure between two of the three lines.
Three-phase line-to-neutral
If you know the voltage between one line and the neutral, the formula uses a factor of 3 instead of √3: S = 3 × I × V ÷ 1,000, because each of the three phases carries the current at its own phase voltage. For 10 amperes at 240 volts line-to-neutral, the result is 7.2 kVA. Choose the line-to-neutral option, because the same numbers give a different answer depending on which voltage they are. A common mistake is to use the line-to-line formula with a phase voltage.
kVA to amps
To find the current, multiply the kVA by 1,000 and divide by the voltage. For three-phase, the divisor also contains the factor: I = S × 1,000 ÷ (√3 × V) for the line-to-line voltage, and I = S × 1,000 ÷ (3 × V) for the line-to-neutral voltage. These are rearrangements of the formulas above. A 50 kVA three-phase transformer at 240 volts gives about 120.28 amperes, and 30 amperes at 220 volts is 11.43 kVA.
kW and the power factor
The power factor is the ratio of the real power to the apparent power [1]; for ordinary loads it lies between 0 and 1. To find the kW from the kVA, multiply by the power factor, and to find the kVA from the kW, divide by it. These two steps are our own rearrangement of the definition. For 2.4 kVA at a power factor of 0.8, the real power is 1.92 kW, and for 1.92 kW the apparent power is 2.4 kVA. The kW can never be more than the kVA.
Reactive power
The real power is P = S × cos φ and the reactive power is Q = S × sin φ, where φ is the phase angle and the power factor is cos φ [1]. The unit of reactive power is the var, so the tool shows kvar. Enter a power factor and the calculator gives the apparent power, the real power and the reactive power. A motor of 5 kW at 400 volts and 8.6 amperes gives about 5.96 kVA, a power factor of 0.84 and about 3.24 kvar.
Sizing a transformer
The same formulas size a transformer: kVA = I × V ÷ 1,000 for single-phase and kVA = I × V × √3 ÷ 1,000 for three-phase, so 250 amperes at 2,000 volts three-phase gives 866 kVA. In this calculator the optional spare capacity is our own working: the kVA times one plus the percentage. Round up to a standard rating, and let an engineer confirm the size.
Generators and supplies
A generator rated in kVA can supply up to that many kVA at any power factor, but only kVA times its power factor in kW. A generator of 500 kVA can supply up to 500 kW only at a power factor of 1, the case of a purely resistive load, where apparent and real power are equal [2]. At 0.8, the same generator supplies 400 kW. Use the kW from kVA option to check how much real power a rated supply can deliver.
Using the calculator
Choose the supply, pick what to find, and fill in the boxes that appear. Compare the single-phase and three-phase results for the same current and voltage, and watch how the power factor splits the apparent power into real and reactive parts. The values are for balanced supplies, and the voltage must be the one that matches your choice. Always confirm cable and device ratings with the local code.
Three phase calculator uses
The three phase options also work as a simple three phase calculator. Enter the line voltage and current to get the apparent power, add the power factor to split it into real and reactive power, and compare the result with the single-phase figure for the same numbers. Use the line values, and remember that the formulas assume a balanced load.
Common mistakes
- Using a phase voltage in the line-to-line formula. Pick the option that matches the voltage you measured.
- Treating kVA as kW. They are equal only at a power factor of 1.
- Entering the power factor as a percentage. Use 0.8, not 80.
- Skipping the margin. Real loads grow, so add spare capacity before choosing a rating.
What next
Use this often? Add Kva to your Home screen.
Frequently asked questions
What is a kVA calculator?
A tool that finds the apparent power of a supply and converts between kVA, kW and amps.
How do you calculate kVA for a single-phase supply?
kVA = amps × volts ÷ 1,000.
How do you convert kVA to amps for a three-phase supply?
Amps = kVA × 1,000 ÷ (√3 × line-to-line volts).
How do you convert kVA to kW?
Multiply the kVA by the power factor.
Does this kVA calculator size a transformer?
It gives the kVA of a load and an optional spare capacity. A qualified engineer must choose the real rating.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.