Saved

Press the star next to a tool's name to save it.

All my tools

FIRE Flow Calculator

Use this fire flow calculator to estimate the required fire flow of a building in gallons and litres per minute with the National Fire Academy or Iowa State method.

Restored your last values ·

%

Choose the National Fire Academy method, which uses the floor area and the floors on fire, or the Iowa State method, which uses the building volume. You can set how much of the building is involved and add exposures to nearby floors or buildings.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose a method, enter the building size and press Estimate fire flow.

See full result

A fire flow calculator estimates the required fire flow (RFF): the amount of water, usually in gallons per minute, needed to suppress or control a fire in a building. Choose a method, enter the building size, and the calculator gives the flow in gallons and litres per minute. It is an estimate for study and rough comparison, not for the design of fire protection. It runs in your browser and nothing you enter is sent anywhere.

What required fire flow is

The required fire flow is the amount of water needed to suppress or control a fire effectively. The insurance-industry grading body ISO calls its version the needed fire flow and says it ranges from 500 to 12,000 gallons per minute for individual buildings.[4] Our own working adds that the real flow depends on the nature of the fire, the wind and the materials involved, and that every formula gives only an estimate. Keep this in mind when you read the result.

How to use the fire flow calculator

  1. Choose US or Metric units and the method.
  2. Enter the building length and width, and the height for the Iowa State method.
  3. Enter the floors on fire, the fire involvement and the exposures, if they apply.
  4. Press Estimate fire flow.

The National Fire Academy method

The National Fire Academy method is taught as the length times the width of the building, in feet, divided by 3, giving the gallons per minute for one story fully involved, which is then multiplied by the percentage of involvement.[2] Firehouse also describes applying the formula to the estimated square footage and multiplying by the number of floors involved.[1] The result is in gallons per minute. For a single-story building of 20 feet by 20 feet, that is 400 divided by 3, which is about 133 gallons per minute. As a small example of our own, an area of 6 by 4 feet gives 24 divided by 3, which is 8 gallons per minute, or about 30 liters per minute.

The Iowa State University method

The Iowa State method is simpler: the cubic feet of the involved space divided by 100 gives the gallons per minute needed to knock down a fire in a single open area that is fully involved.[3] Written out, that is length times width times height over 100. The calculator takes the three sizes in feet, as in the first method, so a building of 20 by 20 by 10 feet has a volume of 4,000 and a flow of 40 gallons per minute. Because a volume is used, a tall building gives a bigger answer than a low one with the same floor area.

Involvement and exposures

The National Fire Academy formula multiplies by the percentage of involvement, so 50 percent involvement gives half of the flow, and the calculator multiplies the result by the involvement you enter.[2] Exposures add to the flow. For an interior exposure, 25 percent of the fire floor's flow is added for each floor above the fire, up to five floors. For an exterior exposure, 25 percent of the fire building's flow is added for each exposed structure.[1][2] The calculator adds 25 percent for each exposure you enter, of either kind.

The upper limit

ISO states that needed fire flows for individual buildings run from a minimum of 500 gallons per minute to a maximum of 12,000.[4] The calculator caps its result at 12,000 gallons per minute, which is about 45,500 liters per minute by our own conversion, and tells you when it does.

Using the result

The result shows the flow in gallons and litres per minute and the value before involvement and exposures. Use it to compare buildings, to learn how the methods differ, or to check a rough number. Do not use it to size a water supply, a pump or a sprinkler system. Those need a qualified fire protection engineer who applies the codes of your area.

Comparing the two methods

The two methods do not measure the same thing, so they give different results for the same building. The National Fire Academy method depends on the floor area and the number of floors on fire, while the Iowa State method depends on the volume. For a low building with a large floor, the first gives the bigger answer, and for a tall building with a small floor, the second may be bigger. Running both is a useful way to see how sensitive an estimate is to the method chosen, and Fire Engineering notes that the current National Fire Academy formula replaced an earlier one that used volume and an occupancy factor, so more than one method has been in use.[2]

Learning with the calculator

Students and people who are interested in the subject can change one input at a time and watch the result. Double the length, and the flow doubles. Add a second floor on fire with the first method, and it doubles again. Add one exposure and the flow rises by a quarter of its value. Set the involvement to 50 percent and it halves. These simple relationships are the whole of the calculation, and seeing them in action makes the formulas easier to remember.

Limits of the estimate

Our own working is that the estimate takes no account of the construction, the contents, the water supply or the tactics of the fire service. A building with a lot of fuel burns harder than an empty one of the same size. Because of this, the result should never be used to decide how much water a building needs. Fire protection design follows the codes and standards of your area and is carried out by a qualified engineer.

Common mistakes

  • Entering meters in the feet option. Choose the metric option for metres.
  • Counting every floor. Use only the floors on fire, and count the others as exposures.
  • Forgetting the height for the Iowa State method. It uses the volume.
  • Treating it as a design tool. It is an estimate.

What next

Use this often? Add FIRE Flow to your Home screen.

Frequently asked questions

What is a fire flow calculator?

A tool that estimates the required fire flow, the water needed to suppress a fire, using a formula such as the National Fire Academy method.

What is the National Fire Academy formula?

Length times width in feet, divided by 3, times the number of floors on fire, in gallons per minute.

What is the Iowa State University formula?

The building volume divided by 100, in gallons per minute.

What is the maximum fire flow?

ISO gives 12,000 gallons per minute (about 45,500 liters per minute) as the maximum needed fire flow for an individual building.

Is the result accurate?

It is an estimate. Real fire flow depends on the fire, wind and materials, and fire protection design needs an engineer.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Everyday Life Tools