Chemical Oxygen Demand Calculator

Use this chemical oxygen demand calculator to find COD in mg/L from the FAS volumes of the blank and the sample, the FAS normality and the sample volume.

Restored your last values ·

mL
mL
N
mL

Enter the volume of FAS used to titrate the blank, the volume used for the sample, the normality of the FAS and the volume of the sample, all volumes in millilitres. You get the chemical oxygen demand in mg/L.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the four values, then press Calculate.

See full result

A chemical oxygen demand calculator turns the titration readings of a COD test into a result in milligrams of oxygen per litre. Enter the volume of FAS used for the blank and for the sample, the normality of the FAS and the sample volume, and it applies the standard formula.

How to use the chemical oxygen demand calculator

  1. Enter the FAS volume for the blank and for the sample, in mL.
  2. Enter the FAS normality and the sample volume.
  3. Press Calculate to see the COD in mg/L.

What chemical oxygen demand tells you

Chemical oxygen demand, or COD, expresses how much oxygen it takes to oxidise the matter in a water sample, as a mass of oxygen per litre of water. The more oxidisable material the sample holds, the higher the figure. Wikipedia states that when millilitres are used consistently for the volumes, the result of the calculation comes out in mg/L [2]. A laboratory handout from IIT Delhi says COD indicates the extent of organic matter contamination of water [1]. It does not identify the pollutants in the water, and it does not prove that the water is safe, which is our own reading of what a single figure can show.

The formula

The closed reflux titrimetric method in the IIT Delhi handout, which cites Standard Methods 5220 C, gives COD in mg/L as (A − B) × M × 8000 ÷ sample volume, where A is the volume of FAS used for the blank, B is the volume used for the sample and M is the molarity of the FAS [1]. Wikipedia names the same quantities as b, s and n, the volume for the blank, the volume for the sample and the normality of the FAS [2]. The calculator subtracts the sample reading from the blank reading, multiplies by the normality and by 8000, and divides by the volume of the sample.

Where the 8000 comes from

The handout explains the constant 8000 as the milliequivalent weight of oxygen times 1,000 mL per litre [1]. In our own words, oxygen has an equivalent weight of 8 grams per equivalent, so the factor turns equivalents of FAS into milligrams of oxygen per litre. We did not open the Standard Methods text itself, only the handout that cites it.

A worked example

Our first example uses a blank of 300 mL, a sample reading of 129 mL, a normality of 3 and a sample volume of 45,000 mL. The difference is 171 mL. Multiplying by 3 gives 513, by 8000 gives 4,104,000, and dividing by 45,000 gives 91.2 mg/L. The calculator gives this figure. The inputs are unrealistic, as a 45-litre sample is far larger than a normal test portion, but the arithmetic is correct.

A more realistic check

For a check that looks more like a bench test, try a blank of 24.5 mL, a sample reading of 12.5 mL, a normality of 0.25 and a 20 mL sample. The difference is 12 mL, and 12 × 0.25 × 8000 ÷ 20 gives 1,200 mg/L. These numbers are our own, chosen only to show the formula working with ordinary laboratory volumes. They are not data from a real sample.

Negative results and test errors

A negative result is a sign of a test error, and the test should be run again; this is our own reasoning from the formula. A negative result happens when the sample uses more FAS than the blank. The calculator stops with a message in that case instead of printing a negative COD. If the blank and the sample use exactly the same volume, the result is zero, and the calculator tells you to check the readings.

Strong samples

A strong sample may need dilution. This calculator has no dilution box, and the pages we opened give no worked method for diluted samples, so check how your laboratory method handles a dilution before you use the result. Enter the volumes exactly as your method defines them. The calculator does not guess, and it cannot know whether the sample volume you type is a diluted portion.

Units to use

Enter all three volumes in millilitres. Enter the normality in equivalents per litre, written N. The handout uses the molarity of the FAS [1]. For FAS, one mole supplies one equivalent, so molarity and normality are the same number, which is our own working. If your burette readings are in litres, convert them to millilitres first, because mixing the units changes the answer by a factor of 1,000. The result is always in milligrams of oxygen per litre.

What the calculator leaves out

The tool does not judge whether a value is acceptable, because limits depend on the use and the regulation, and we opened no regulatory page. COD also says nothing about which substances are present, and it is not a compliance or safety test. Use the number as one figure from a laboratory procedure, together with the quality checks, calibration and records that your method requires.

Using the calculator

Type the four values from your titration record and press the button. Read the COD in mg/L, with the volume difference and the working shown beneath it. If the answer is far from what you expect, check the order of the readings first: the blank goes in the first box and the sample in the second. Then check that the volumes are all in millilitres and that the normality is the one for the FAS you used.

Common mistakes

  • Swapping the blank and the sample readings. The blank goes in the first box; it should be larger.
  • Mixing litres and millilitres. All three volumes are in mL.
  • Using the wrong normality. Use the normality of the FAS, not of another reagent.
  • Treating COD as a safety test. It is a single measurement of oxygen demand.

What next

Use this often? Add Chemical Oxy to your Home screen.

Frequently asked questions

What is a chemical oxygen demand calculator?

A tool that turns the FAS readings of a COD test into a result in milligrams of oxygen per litre.

What is the COD formula?

COD = 8000 × (blank − sample) × normality ÷ sample volume, with all volumes in millilitres.

What units does the result have?

Milligrams of oxygen per litre, when the volumes are all in millilitres.

Why is my COD negative?

The sample used more FAS than the blank, which points to a test error. Rerun the test.

Does COD show that water is safe?

No. COD does not identify the pollutants and does not prove that water is safe.

What went wrong?