A broad-crested weir calculator estimates the discharge of water over a weir with a flat crest from the width of the crest and the head of water above it. It uses the general weir flow equation with an average coefficient, and gives the flow in cubic feet per second, gallons per minute, litres per second and cubic metres per second.
How to use the broad-crested weir calculator
- Choose US or metric units.
- Enter the width of the crest and the head over it.
- Change the coefficient if you have a better value.
- Press Calculate.
The weir
A weir is a barrier across a stream or a channel over which the water flows, and it can be used to control the level or to measure the flow [1]. A broad-crested weir is a flat-crested structure, where the water passes over a crest that covers much or all of the width of the channel [1]. The page says that it is one of the most common types found in the world [1].
The equation
The page gives the flow over a weir in general form as Q = C L H^n [1]. Q is the flow rate, C the flow coefficient, L the width of the crest, H the head of water over the crest, and n the exponent, 3/2 for a horizontal weir and 5/2 for a V-notch weir [1]. The calculator uses the 3/2 exponent for a horizontal crest.
The coefficient
The page gives the flow coefficient as an average figure of 3.33 [1]. It does not state the units. We take it to be for the head and the width in feet and the flow in cubic feet per second, which is the classical form of the equation, and this is our own assumption. The calculator therefore converts metric inputs to feet before it applies the equation.
A worked example
A weir with a crest of 10 feet and a head of 1 foot gives Q = 3.33 × 10 × 1^1.5 = 33.3 cubic feet per second, which is 14,946 US gallons per minute or 0.943 cubic metres per second. In metric units, a crest of 3.048 metres and a head of 0.3048 metres give the same flow. If the head doubles, the flow goes up by a factor of 2^1.5, which is 2.83.
The head
The head H is the depth of water above the crest, measured upstream of the weir, away from the drawdown near the crest. It is not the height of the water above the stream bed. A good measurement matters a great deal, since the flow depends on H to the power of 3/2: an error of 10 percent in H gives about 15 percent in Q.
Own coefficient
The average coefficient 3.33 is only a guide. The real value depends on the shape of the crest, its roughness, the head, and the height of the weir. If you have a calibrated coefficient for your weir, enter it in the box and the calculator uses it in the same equation. For a design, check against a standard that applies to your weir, as these vary by country.
Units
Enter the crest width and the head in feet or in metres. The result is given in cubic feet per second, US gallons per minute, litres per second and cubic metres per second. One cubic foot per second is 448.83 US gallons per minute, and one cubic foot is 28.3168 litres. These conversion factors are our own.
V-notch weirs
The page also gives the Kindsvater–Shen equation for a V-notch weir, in feet and seconds, but its form is garbled in the text that we could read, so it is not in the calculator. For a V-notch, the exponent is 5/2 and the coefficient differs from the horizontal weir, so this calculator should not be used for a notch.
Limits
The equation is an empirical rule. It is for free flow over the weir, with the water falling freely downstream. If the downstream level rises above the crest, the weir is submerged and the flow is less. The calculator does not allow for the velocity of approach, side contraction or a crest that is not level. It gives a first estimate, which is enough for planning.
Using the calculator
Select the units, enter the width of the crest and the head, and press the button. Leave the coefficient blank for 3.33. To compare designs, change the width or the head and see how the flow responds. To find the head for a given flow, try values until the flow matches, since the flow rises steadily with the head.
Sizing a weir
To size a weir for a given flow, work out the head that it needs. For a flow of 33.3 cubic feet per second and a crest of 10 feet, the head is 1 foot. With a crest of 20 feet, the same flow needs a head of only 0.63 feet, since the head goes as the flow to the power 2/3, divided by the width. A wider crest therefore lowers the water level upstream, which is why wide weirs are used to control flood levels.
Common mistakes
- Measuring the head from the bed. Measure it above the crest.
- Entering metres in the feet setting. Check the units.
- Using 3.33 for a V-notch. The notch needs its own equation.
- Ignoring submergence. Free flow is assumed.
What next
Use this often? Add Broad-Creste to your Home screen.
Frequently asked questions
What is a broad-crested weir calculator?
A tool that estimates the flow of water over a flat-crested weir.
What is the weir flow equation?
Q = C L H^n, with n = 3/2 for a horizontal weir.
What is the typical flow coefficient?
An average of 3.33, in feet and seconds.
How does the flow change with the head?
It rises with H to the power 3/2, so doubling the head gives 2.83 times the flow.
Does the calculator cover V-notch weirs?
No. A V-notch uses the exponent 5/2 and a different coefficient.