Saved

Press the star next to a tool's name to save it.

All my tools

Beer Lambert Law Calculator

Use this Beer Lambert law calculator to find absorbance, concentration, path length or the absorption coefficient, convert transmittance to absorbance, and work out light attenuation and protein concentration.

Restored your last values ·

Choose a job. For the Beer-Lambert law, pick the quantity to find and enter the other three. You can also convert transmittance and absorbance, work out how much light survives a layer, or get a protein concentration from a reading at 280 nm.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose what you want and fill in the boxes, then press Calculate.

See full result

The Beer Lambert law calculator links the absorbance of a solution to its concentration, the path length of light through it and the absorption coefficient of the substance. Pick the quantity you want, enter the other three, and read the answer. The same page converts transmittance to absorbance, works out how much light passes through a layer with the attenuation law, and estimates protein concentration from the absorbance at 280 nm.

How to use the Beer Lambert law calculator

  1. Choose what you want: the Beer-Lambert law, transmittance, attenuation or protein concentration.
  2. For the law, choose which quantity to find and enter the other three.
  3. For the other jobs, enter the values that the boxes ask for.
  4. Press Calculate.

The law

The Wikipedia page on the Beer-Lambert law writes the law as A = εcl, where A is absorbance, ε is the absorption coefficient, c is the concentration of the absorbing substance and l is the path length [1]. Absorbance is defined as the logarithm to base 10 of the incident intensity over the transmitted intensity, so log10(I0/I) = A = εlc [1]. The page states no units. A common choice is ε in litres per mole per centimetre, l in centimetres and c in moles per litre, so that A has no unit; keep the same unit system throughout.

Worked example

A substance with ε = 1,000 L/(mol·cm) in a 1 cm cell with an absorbance of 0.5 has a concentration of 0.5 divided by 1,000 times 1, which is 0.0005 mol/L. Going the other way, ε of 1,000, l of 1 and c of 0.0005 give A = 0.5, and 31.6 percent of the light gets through. The calculator shows the transmitted share as 10 raised to the power minus A, which follows from the two definitions above. This example is our own calculation.

Transmittance and absorbance

Transmittance is the ratio of transmitted to incident light, T = I/I0 [1]. Because absorbance is log10(I0/I), it equals minus log10 of T. A transmittance of 50 percent has an absorbance of 0.30103, and an absorbance of 1 means that 10 percent of the light gets through. The page also defines a natural-log absorbance, τ = ln(10) times A, which for A = 0.30103 is 0.693147 [1]. The calculator shows it when you convert from transmittance.

The best range

The page says that absorbance between 0.2 and 0.5 is ideal for keeping the law linear [1]. Readings far below that are noisy, and strong absorbance means too much sample, so dilute it and measure again. The calculator adds a note when your absorbance is outside the range.

Attenuation through a layer

For light or radiation passing through a thin layer of uniform material, the intensity falls as I(d) = I0 times e to the power minus αd [2]. The page uses the symbol μ for the attenuation coefficient in other places, and the SI unit is the reciprocal metre [2]. A decadic coefficient is μ divided by ln 10, so that transmittance is 10 to the power minus μ10 times the length [2]. The half-value layer is the thickness that cuts the radiation to half [2]; with a constant coefficient it is ln 2 divided by μ, which is our own working. With I0 of 100, μ of 0.5 per unit and a layer of 2 units, I is 36.79, and the half-value layer is 1.386.

Protein at 280 nm

A protein concentration can be found by measuring the optical density at 280 nm and comparing with a standard curve [3]. The page says this is not the most accurate method, because protein composition varies a lot and nucleic acid contamination adds to the reading [3]. It lists the Biuret, Lowry, BCA and Bradford assays as more accurate alternatives [3]. The page gives no extinction coefficient, so you enter the absorbance of a 1 mg/mL solution in a 1 cm path for your protein, and the calculator divides: an A280 of 1 with an ε of 1 in a 1 cm path is 1 mg/mL. That division is our working.

Choosing the quantity to find

Laboratories use the law in several ways. To find a concentration, measure the absorbance of a sample in a cell of known path length and divide by the absorption coefficient. To find the absorption coefficient, measure a solution of known concentration. To check a cell, measure a known solution and solve for the path length. Choose the quantity in the first list and the calculator hides the box that you do not need.

Making a calibration

Real work rarely relies on one measurement. A calibration curve of absorbance against concentration for several standards gives a straight line whose slope is the product of the absorption coefficient and the path length. Compare the line with your results, and keep the sample inside the range where the line is straight.

Common mistakes

  • Mixing units. If ε is per centimetre, enter the path in centimetres.
  • Using high absorbance. Above about 0.5 the law may not stay linear.
  • Treating A280 as exact. The protein mix and nucleic acids change the reading.
  • Confusing the two logarithms. Absorbance uses log base 10, while the attenuation law uses e.

What next

Use this often? Add Beer Lambert to your Home screen.

Frequently asked questions

What is a Beer Lambert law calculator?

A tool that uses A = εcl to find absorbance, concentration, path length or the absorption coefficient, and that also converts transmittance and absorbance.

What is the Beer-Lambert law formula?

A = εcl, where A is absorbance, ε the absorption coefficient, c the concentration and l the path length. Absorbance is log10(I0/I).

How do I convert transmittance to absorbance?

Take minus the base 10 logarithm of the transmittance as a fraction. 50 percent gives 0.30103, and 10 percent gives 1.

What absorbance range is best?

The page gives 0.2 to 0.5 as ideal for keeping the law linear.

How do I find protein concentration from A280?

Divide the absorbance by the absorbance of a 1 mg/mL solution and by the path in centimetres. The method is not the most accurate, so use a standard curve for important work.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Physics & Science Tools