A water heater size calculator turns the way your household uses hot water into a number you can shop with. For a storage tank that number is the first hour rating. For a tankless unit it is the flow rate and the temperature rise. This page does both, using the U.S. Department of Energy sizing method. [1]
How to use the water heater size calculator
- Pick Storage tank or Tankless at the top.
- For a tank, enter how many showers, shaves, hand-washing or food prep sessions, dishwasher loads and clothes washer loads happen in the busiest single hour of your day.
- For a tankless heater, enter how many showers and faucets can run at the same moment. Leave the flow and temperature boxes empty to use the DOE defaults, or type your own.
- Press Calculate. A tank gives a peak hour demand and a range of first hour ratings. A tankless unit gives the flow, the temperature rise and the heat output needed.
How the water heater size calculator sizes a storage tank
The DOE says to size a storage water heater, including a heat pump model with a tank, by its first hour rating. [1] That rating is the number of gallons of hot water the heater can supply in an hour, starting with a full tank. It depends on the tank size, the heat source and the size of the burner or element. You can find it on the EnergyGuide label, in the top left corner, printed as capacity (first hour rating). [1]
Your own need is the peak hour demand: the hot water you use in the busiest hour of the day. The DOE worksheet gives an average amount of hot water for each use, and you multiply by how many times it happens in that hour. [1]
| Use | Hot water per use |
|---|---|
| Shower | 10 gallons |
| Shaving | 2 gallons |
| Hand dishwashing or food prep | 4 gallons |
| Automatic dishwasher | 6 gallons |
| Clothes washer | 7 gallons |
The DOE then says to look for a model whose first hour rating matches your peak hour demand within 1 or 2 gallons. [1] The calculator shows that range as the peak minus 2 up to the peak plus 2.
Worked example for a family of four
The DOE worksheet example has three showers, one shave and one hand dishwashing in the same hour. That is 3 × 10 + 1 × 2 + 1 × 4, which gives a peak hour demand of 36 gallons, so the household needs a first hour rating of 34 to 38 gallons. [1] Enter 3, 1 and 1 in the first three boxes and the calculator returns the same figures. In metric mode it also shows the demand in litres, about 136 L.
How it sizes a tankless water heater
A tankless or demand-type heater has no first hour rating. It is rated by the temperature rise it can give at a certain flow rate. [1] You list the hot water devices that may run together and add their flow rates. The DOE example runs a 0.75 gallon per minute faucet and a 2.5 gallon per minute shower, so the heater must supply at least 3.25 gallons per minute. [1]
The temperature rise is the hot water temperature you want minus the temperature of the water coming in. Unless you know better, the DOE assumes 50 °F coming in and 120 °F out, a 70 °F rise. For a dishwasher without an internal heater you might want 140 °F, a 90 °F rise. [1]
The DOE also says a 70 °F rise is typically possible at 5 gallons per minute through gas-fired demand heaters and 2 gallons per minute through electric ones. [1] The calculator compares your flow and rise with those two figures. This is a rough check only. Every model has its own chart, so use the maker’s numbers for the final choice.
As an extra, the calculator works out the heat output needed in Btu per hour and kilowatts. This is our own working from basic physics: one gallon of water weighs about 8.3454 pounds, it takes about one Btu to warm a pound of water by one degree Fahrenheit, and there are 60 minutes in an hour. So Btu per hour is the flow in gallons per minute × 8.3454 × 60 × the rise in °F. One kilowatt is 3,412 Btu per hour. For the DOE flow of 3.25 gallons per minute and a 70 °F rise that is about 113,900 Btu per hour, or 33.4 kW.
Tips for choosing a water heater size
- Think about your busiest hour, not the day. A morning with four showers in a row matters more than the total over 24 hours.
- The worksheet assumes standard usage with no water conservation measures. [1] Low-flow shower heads and fixtures lower the demand.
- If the peak falls between two model sizes, the DOE range of 1 or 2 gallons helps you decide. Going a little larger is usually safer than going smaller.
- For a tankless heater, a lower incoming water temperature in winter raises the rise you need. If you live where ground water is cold, enter the real figure.
- Solar, combination space and water heating, indirect and tankless coil systems need a qualified contractor. [1]
Common mistakes
- Adding up a whole day of hot water. The worksheet estimates only the single busiest hour. [1]
- Forgetting that a dishwasher without an internal heater may want 140 °F water. [1]
- Choosing a tankless unit from its maximum flow alone. The flow it can deliver falls as the required rise gets bigger.
Limits of this estimate
The calculator uses the DOE average gallons for each use. A rain shower head, a large soaking tub or a very long shower will use more than the worksheet figure, and a low-flow fixture will use less. If your habits are far from average, add extra uses to the busiest hour to cover them.
Heat pump and tankless models may also have different recovery and flow behaviour at different inlet temperatures. The only reliable figure for a particular model is the one on its label or data sheet. Use this page to know what to look for, then check the label, ask a licensed plumber and confirm the local code before you buy.
What next
Use this often? Add Water Heater to your Home screen.
Frequently asked questions
How does a water heater size calculator work out the size?
For a tank it adds the hot water used in your busiest hour, using the DOE worksheet gallons for each use, and shows a first hour rating within 2 gallons of that peak. For a tankless heater it adds the flow of the devices running together and the temperature rise needed.
What is a first hour rating?
It is the number of gallons of hot water a storage water heater can supply in one hour starting with a full tank. It is printed on the EnergyGuide label as capacity (first hour rating).
What temperature rise do I need for a tankless water heater?
Subtract the incoming water temperature from the hot water temperature you want. The DOE assumes 50 °F in and 120 °F out unless you know otherwise, which is a 70 °F rise.
Why does the result show a range?
The DOE advises choosing a model whose first hour rating is within 1 or 2 gallons of your peak hour demand, so the calculator shows the peak minus 2 up to the peak plus 2.
Is the water heater size result a quote or a guarantee?
No. It is an estimate from average figures. Real use varies, and a licensed plumber or the heater maker should confirm the size.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.