Saved

Press the star next to a tool's name to save it.

All my tools

Serial Dilution Calculator

Use this serial dilution calculator to find the concentration after each step, the total dilution factor and the volumes to transfer, or the number of steps needed to reach a target.

Restored your last values ·

Enter the starting concentration and either the dilution factor or the volumes transferred and added. You get the concentration after every step and the volumes for each tube. Or enter a target and find how many steps it takes.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the starting concentration and the dilution factor, then press Calculate.

See full result

A serial dilution calculator shows the concentration after each step of a series in which every tube is made by diluting the one before it. Enter the starting concentration and the dilution factor, or the volume that you transfer and the diluent you add, and it gives the concentration of every tube, the total dilution factor and the volumes to pipette. It can also tell you how many steps you need to reach a target.

How to use the serial dilution calculator

  1. Choose whether you want the concentration after each step or the steps to a target.
  2. Enter the starting concentration and the dilution factor, or the transfer volume and the diluent volume.
  3. Add the number of steps and the volume per tube.
  4. Press Calculate.

What a serial dilution is

A serial dilution is a step-wise dilution of a substance in solution, using either a constant dilution factor or a variable factor between the dilutions [1]. With a constant factor, the concentration falls in a geometric progression, which is a logarithmic series [1]. A ten-fold series could be 1 M, 0.1 M, 0.01 M, 0.001 M and so on [1]. Serial dilutions are used to make highly diluted solutions accurately and to prepare concentration curves with a logarithmic scale [1].

The formula

After n steps with a dilution factor DF, the concentration is the starting concentration divided by DF raised to the power n, and the total dilution factor is DF to the power n. The formula is our own working and is not stated on the pages that we read. From a start of 1 and a factor of 10, four steps give 0.0001, and the total dilution is 10,000-fold. A factor of 2 from 1,000 gives 500, 250 and 125 after three steps.

Dilution factor from volumes

The dilution factor of one step is the final volume divided by the volume that you transfer. If you move 1 mL into 9 mL of diluent, the final volume is 10 mL and the factor is 10. If you move 5 mL into 5 mL, the factor is 2. The calculator works out the factor from the transfer and diluent volumes, and the other way round it works out the transfer volume for a given tube volume: the volume per tube divided by the factor.

The basic equation

Each step follows the equation for a dilution, c1V1 = c2V2, where c1 and V1 are the concentration and volume of the stock that you take, and c2 and V2 are the concentration and volume you make [2]. A dilution means adding solvent without adding solute, so the amount of solute is unchanged [2]. For a tube of 10 mL at a factor of 10, take 1 mL from the previous tube and add 9 mL of diluent.

Named series

The page names the ten-fold step a logarithmic dilution or log-dilution, the 3.16-fold step, which is the square root of 10, a half-logarithmic dilution, and the 1.78-fold step, the fourth root of 10, a quarter-logarithmic dilution [1]. The calculator names your series when the factor matches. Half-log series give twice as many points per decade, which helps when you draw a curve.

Steps to a target

To find how many steps take you from a starting concentration to a target, divide the logarithm of the ratio by the logarithm of the factor and round up. From 1 to 0.0005 at a factor of 10 takes 4 steps, which ends at 0.0001, at or below the target. If you need exactly the target, use a different factor for the last step.

Worked example

A laboratory needs standards from a stock of 1,000 µg/mL. A two-fold series in tubes of 10 mL transfers 5 mL into 5 mL of diluent each time. After 5 steps the tubes hold 500, 250, 125, 62.5 and 31.25 µg/mL. These are our own calculations.

Practical tips

Mix every tube thoroughly before you transfer, use a fresh tip for each step, and make a larger volume than you need, because small volumes magnify pipetting errors. Check the last tube against a standard if the result matters.

Where serial dilutions are used

Microbiologists use ten-fold series to count bacteria, spreading a sample from each tube on a plate and counting the colonies. Biochemists use series to build standard curves and to test a drug over a wide range of concentrations. Analysts use them to bring a sample with a very high concentration into the range of an instrument. A half-logarithmic or two-fold series gives more points across the range at the cost of more tubes.

Checking your series

Test the calculator with a simple case. With a factor of 10 each tube should be one tenth of the one before, and the exponents of the concentrations should step down by one. If you enter a transfer volume of 1 and a diluent volume of 9, the factor must come out as 10, and if you enter 1 and 1 it must come out as 2. A factor of 1 or less is rejected, since a dilution must make the solution weaker. These checks help you catch a wrong tube volume before you pipette.

Common mistakes

  • Transferring from the wrong tube. Always take from the previous tube.
  • Mixing the dilution factor with the ratio. A 1 to 10 dilution has a factor of 10.
  • Adding the transfer volume to the diluent twice. The factor is the final volume over the transfer.
  • Forgetting the total dilution. It is the factor raised to the number of steps.

What next

Use this often? Add Serial Dilut to your Home screen.

Frequently asked questions

What is a serial dilution calculator?

A tool that gives the concentration after each step of a serial dilution, the total dilution factor, and the volumes to transfer and to add.

How do I calculate a serial dilution?

Divide the starting concentration by the dilution factor raised to the number of steps. From 1 M with a factor of 10, four steps give 0.0001 M.

What is the dilution factor?

The final volume divided by the volume transferred. 1 mL in 9 mL of diluent makes 10 mL, so the factor is 10.

What is a half-log dilution?

A series with a factor of about 3.16, the square root of 10, so that two steps make a ten-fold change.

How many steps do I need?

Divide the logarithm of the starting concentration over the target by the logarithm of the factor, and round up.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Physics & Science Tools