Room Heater Size Calculator

Use this room heater size calculator to estimate the watts and Btu per hour a room needs from its floor area, ceiling height and insulation, using the common 10 watts per square foot rule.

Restored your last values ·

Enter the length and width of the room, or its floor area, the ceiling height and how well the room is insulated.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the size of the room and the ceiling height, then press Calculate.

See full result

This room heater size calculator estimates how many watts of heating a room needs. You enter the floor area, the ceiling height and how well insulated the room is, and it gives the heater size in watts and in Btu per hour. It uses the common rule of thumb of about 10 watts per square foot, raised for poor insulation and tall ceilings.

How to use the room heater size calculator

  1. Choose US or Metric units.
  2. Enter the length and width of the room, or its floor area.
  3. Enter the ceiling height. Leave it blank for a standard 8 foot ceiling.
  4. Pick the insulation level that best describes the room.
  5. Press Calculate to see the watts, Btu per hour, the number of 1,500 watt heaters and the current.

The sizing rule

Watts needed equal the floor area in square feet times the watts per square foot, scaled up by the ceiling height divided by 8 feet when the ceiling is taller. The figures are 10 watts per square foot for a well insulated room, 12 for average insulation and 15 for a poorly insulated room. These are widely quoted rules of thumb and our own working basis. They are not official figures and assume a room with an 8 foot ceiling.

InsulationWatts per sq ftHeater for 180 sq ft
Well insulated101,800 W
Average122,160 W
Poorly insulated152,700 W

Converting watts to Btu per hour

Heaters in the US are often rated in Btu per hour. One watt is approximately 3.412142 Btu per hour. [2] The calculator multiplies the watts by that figure. An electric space heater turns essentially all the electricity it uses into heat, so its watt rating is its heat output. [1]

Worked example

A bedroom measures 15 ft by 12 ft with an 8 ft ceiling and good insulation. The floor area is 180 square feet. At 10 watts per square foot the heater needs about 1,800 watts, which is 6,142 Btu per hour. That is two heaters of 1,500 watts, or one larger unit. If the ceiling were 10 ft, the figure rises by 10 divided by 8, to 2,250 watts. With poor insulation the same room needs 2,700 watts.

What changes the result

  • Ceiling height: more air to warm, so more watts.
  • Insulation and windows: single glazing and thin walls lose heat faster.
  • Climate: the rule suits mild to moderate winters. A very cold climate needs more.
  • Exposure: a corner room with two outside walls loses more heat than an inner room.
  • Use: a heater that only takes the chill off needs less than one that is the main heat source.

Electrical limits

The calculator shows the current in amps by dividing watts by 120 volts, for a 120 volt household supply. A common 1,500 watt plug-in heater draws 12.5 amps, which is a heavy load for a 15 amp circuit. Many electrical guides advise keeping a continuous load below 80% of the circuit rating. Do not run two big heaters on one circuit, and never use a light extension cord. Ask an electrician if you are unsure what your circuit can carry.

Heater types

Convection and oil-filled heaters warm the air in a room, so the rule above fits them. Radiant heaters warm people and objects in front of them, so claims of heating very large areas should be treated with care. Check the maker’s own coverage guidance and the heater’s safety certification.

Tips for staying warm and safe

  • Close doors and seal drafts before you buy a bigger heater.
  • Keep heaters away from curtains, bedding and furniture.
  • Choose a model with tip-over and overheat protection.
  • Plug the heater straight into a wall outlet.
  • Do not leave a space heater running while you sleep unless its manual says it is safe to do so.

Choosing a heater for a small room

A bathroom, a study or a nursery may need only 750 to 1,000 watts. A bigger heater cycles on and off more often and can overshoot the temperature. Look for a thermostat so the heater holds the room at a steady temperature rather than running flat out. If the room is used for short periods, a smaller heater that runs longer is usually fine.

Running cost

You can work out the running cost from the heater power. A 1,500 watt heater uses 1.5 kilowatt-hours for every hour it runs at full output. Multiply by your price per kilowatt-hour to get the cost. A thermostat means the heater runs at full power only part of the time, so real cost is lower than the full-power figure. Better insulation and draught-proofing reduce the size you need and the running cost together.

When a bigger heater is the wrong answer

If a room never gets warm, check for gaps around windows and doors, a missing loft insulation layer or an open chimney before buying a stronger heater. Fixing the leak lowers the heat loss, which is what the insulation setting in this calculator represents.

Common mistakes

  • Using the floor area of the whole home instead of one room.
  • Ignoring the ceiling height in a loft or vaulted room.
  • Assuming the wattage on the box is the area it can heat.
  • Forgetting that a room with a gas or central system may need no heater at all.

What next

Use this often? Add Room Heater to your Home screen.

Frequently asked questions

How do I use a room heater size calculator?

Enter the room length and width, the ceiling height and the insulation level, then press Calculate. You get the heater size in watts and Btu per hour.

How many watts per square foot does a room need?

A common rule of thumb is about 10 watts per square foot for a well insulated room with an 8 foot ceiling, and 12 to 15 for average or poor insulation.

How many Btu is a 1,500 watt heater?

One watt is approximately 3.412142 Btu per hour, so 1,500 watts is about 5,118 Btu per hour.

Does ceiling height matter?

Yes. A taller ceiling means more air to heat. The calculator scales the result by the ceiling height divided by 8 feet when the ceiling is taller than 8 feet.

Is this enough to size a whole-house system?

No. It is a quick estimate for one room. Whole-house heating needs a proper heat load calculation from a qualified contractor.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Everyday Life Tools