A Passive House calculator that checks a design against the stated criteria: heating demand, cooling demand, airtightness, primary energy and summer overheating. Enter the values you have, and each one is compared with its limit, with the margin or the excess. It is a quick check, not a certification.
How to use the passive house calculator
- Enter any of the values you have, in the units shown.
- For airtightness, type n50 or the air flow and the volume.
- Press Check.
What the check does
It compares each value that you enter with a limit and reports a pass or a fail, with the margin or the excess. A criterion that you leave blank is skipped, so you can check a few values early in a design and the rest later. It does not model the energy balance of a building. That needs a full tool such as the PHPP.
Heating demand
The Passive House Institute catalogue of learning targets sets annual heating demand at no more than 15 kilowatt-hours per square metre and year, as a value for Central Europe [1]. A second route is a peak heating load of no more than 10 watts per square metre, which the Passive house article gives as an alternative [2]. The calculator accepts either one.
Cooling demand
The same catalogue gives 15 kilowatt-hours per square metre and year for cooling, again for Central Europe [1]. Both the heating and the cooling limits depend on the climate, so for another region the value may differ. The calculator uses the Central European figure and says so in the result, which you should keep in mind for hot or very cold sites.
Airtightness
The airtightness limit is an n50 of 0.6 air changes per hour at a pressure difference of 50 pascals [1]. The Passive house article gives the same limit [2]. If you know the air flow at 50 pascals and the internal volume, the calculator divides one by the other to get n50. That division is our own working, and the result shows it.
Primary energy
The catalogue sets primary energy at no more than 120 kilowatt-hours per square metre and year [1]. The document dates from 2012, and the Institute's criteria may have changed since, so this is the older and general figure. Check the current criteria of the Institute before you rely on it for a project.
Summer overheating
The overheating limit is that the share of occupied hours above 25 degrees Celsius should not exceed 10 percent [1]. This is a result of a simulation or a measurement, so the calculator takes it as an input. Enter it as a percentage of the hours of use. If the number is above 10, the check fails and shows the excess.
A worked example
Take heating 12, cooling 10, n50 0.5, primary energy 110 and 5 percent overheating. Every value is below its limit, with margins of 3, 5, 0.1, 10 and 5. All five criteria pass. If the heating demand is 18, it fails by 3, which is 20 percent over the limit. These are our test values, and they are not from a real building.
Payback and savings
This tool does not estimate the payback or the energy savings of a passive house. Those need the energy demand of the house and of a comparison house, the price of each fuel and the extra building cost, and none of our sources gives them. So the tool does the criteria check only, and you can use its margins as an early sign of whether a design is on track.
What a pass means
A pass here means that the values you typed are within the limits, nothing more. Certification follows the Institute's own process, which needs a full calculation of the design and more evidence than these values. Use the calculator to see early whether a design is on track, and then use the proper tools and a certifier.
Using the calculator
Enter what you have. Read the line for each criterion and the summary at the top. If a criterion fails, change the design value and check again. The margin shows how far you are from the limit. Remember that the limits are those of the sources above, which are for Central Europe and from 2012, and that other regions have their own targets.
Reading a fail
A fail shows how far you are over a limit, in the units of the criterion and as a percentage. A small excess may be fixed by more insulation, better windows, a more efficient ventilation heat recovery or a tighter envelope, while a large one may need a change of form or orientation. These suggestions are general, and are not from the sources. Change the design value and check again until the line passes.
Climate and units
All the values are metric, since the limits are given as kilowatt-hours per square metre and year. The calculator does not convert from British thermal units or square feet. The heating and cooling limits are for Central Europe [1], so a design in a very different climate should be compared with the targets that the Institute gives for that region.
Common mistakes
- Mixing units. The values are in kilowatt-hours per square metre and year, and watts per square metre.
- Entering n50 and air flow together. The typed n50 is used.
- Using a hot-climate design with Central European limits. The limits depend on the climate.
- Treating a pass as certification. Certification needs a full calculation and tests.
What next
Use this often? Add Passive Hous to your Home screen.
Frequently asked questions
What is a Passive House calculator?
A tool that compares your design values with stated Passive House limits.
What is the heating demand limit?
15 kilowatt-hours per square metre and year, or a peak load of 10 watts per square metre.
What is the airtightness limit for a Passive House?
An n50 of 0.6 per hour at 50 pascals.
Does the Passive House calculator certify a building?
No. Certification needs a full calculation and tests by an accredited certifier.
Why are some limits for Central Europe?
The heating and cooling limits depend on the climate.