Inverter / Battery Backup Calculator

Enter your battery size and the watts you need to run, and this inverter battery backup calculator estimates the backup time and the battery capacity you would need.

Restored your last values ·

Add up the watts on the labels of everything you will run at the same time. The 85% efficiency is an assumption: change it if your inverter's datasheet gives a figure.

Estimated backup time

–

Enter your battery and load to estimate the backup time.

See full result

An inverter battery backup calculator estimates how long your battery will keep things running during a power cut. Enter your battery's capacity and voltage, the number of batteries and the watts you need to run, and this inverter battery backup calculator gives the expected backup time. It can also work in reverse: tell it how many hours you want, and it shows the battery capacity you would need. That makes it useful both for checking the setup you already own and for choosing a new one.

Inverter battery backup formula

Backup time (hours) = battery Ah × battery voltage × number of batteries × usable charge × inverter efficiency ÷ load in watts

Battery capacity is rated in ampere-hours, or Ah. Multiplying by the voltage gives the energy stored in watt-hours. Not all of that can be used, and the inverter loses some energy while turning the battery's direct current into household alternating current, so those two percentages reduce the total before you divide by the load.

How to use the inverter battery backup calculator

  1. Choose your battery type, or pick Custom and enter your own usable percentage.
  2. Enter the capacity printed on the battery, in Ah, and its voltage. Most home inverter batteries are 12 V.
  3. Enter the number of batteries in your system.
  4. Enter your load in watts. Add up everything you will run at the same time, such as fans, lights, a router and a television.
  5. Add the backup you want if you would like to see what battery size it needs.
  6. Press Calculate backup.

Inverter battery backup example

Take one 150 Ah, 12 V lead-acid battery running a 300 W load. The battery stores 150 × 12 = 1,800 Wh. Using 50% of that gives 900 Wh, and at 85% inverter efficiency about 765 Wh reaches your appliances. The backup is 765 ÷ 300 = 2.55 hours, or about 2 hours 33 minutes. To get 4 hours at the same load you would need about 236 Ah, which means a larger battery or a second one.

What is depth of discharge?

Depth of discharge is how much of a battery's capacity you take out before recharging it. For almost all rechargeable battery types there is a link between depth of discharge and battery life: the deeper you regularly discharge, the fewer charge cycles you get. For lead-acid deep-cycle batteries, an average depth of around 50% has been suggested as the best balance of storage against cost, and that is the figure this calculator uses for them. Lithium iron phosphate batteries are often limited to between 15% and 85% charge to greatly extend their life, a usable range of 70%. Your own system's settings may differ, so choose Custom if you know the real number.

Why the real backup can be shorter

  • Heavy loads. For lead-acid batteries, the available capacity falls as the rate of discharge rises, an effect described by Peukert's law. A battery won't deliver its full rating under a heavy load.
  • Battery age. Capacity gradually falls as a battery wears out.
  • Inverter type. A modified sine wave can make loads run less efficiently, and most AC motors lose about 20% of their efficiency on one.
  • Inverter standby use. The inverter consumes a little power simply by being switched on.

Calculating your load

Look for the wattage printed on each appliance's label or in its manual, then add up everything that will run at the same time. Devices with motors or compressors, such as fridges and pumps, can draw much more for a moment when they start, so check that your inverter can handle that surge as well as the steady load. Reducing the load is the cheapest way to get more backup: halving the watts doubles the hours.

Connecting more than one battery

Two batteries wired in series raise the voltage, while two wired in parallel raise the ampere-hour rating. Either way, the total stored energy in watt-hours is the same, which is why this calculator simply multiplies by the number of batteries. Your inverter must match the system voltage, so check its rating before you add a battery, and use batteries of the same type and age together. If you are unsure about the wiring, ask a qualified electrician.

Common mistakes

  • Using the whole battery capacity. Regularly draining a battery fully shortens its life.
  • Forgetting inverter losses. Not all of the stored energy reaches your appliances.
  • Confusing VA with watts. An inverter's VA rating isn't the same as the watts it can supply, so check its datasheet.
  • Counting only a few appliances. Include everything that will be on at once.

Getting more backup from the same battery

Before you buy anything bigger, try to cut what you run during a power cut. Swap older lights for efficient ones, turn off anything you don't need, and keep heavy heating appliances off the inverter entirely. Keep the batteries charged and follow the maker's care instructions.

Size a rooftop system with the solar panel calculator, convert between watts and other units with the power converter, and work out percentages with the percentage calculator.

This calculator gives an estimate for planning only. Have electrical work done by a qualified electrician.

What next

Use this often? Add Inverter / B to your Home screen.

Frequently asked questions

How does the inverter battery backup calculator work?

It multiplies battery Ah, voltage, the number of batteries, the usable charge and inverter efficiency, then divides by your load in watts.

How long will a 150 Ah battery run a 300 W load?

With a 12 V lead-acid battery, 50% usable charge and 85% efficiency, about 2 hours 33 minutes.

Why does the calculator use only 50% of a lead-acid battery?

Deeper discharges reduce battery life. An average depth of around 50% has been suggested as a good balance for lead-acid deep-cycle batteries.

What battery size do I need for 4 hours of backup?

Enter your load and 4 in the backup box. The calculator shows the capacity each battery needs.

Does connecting batteries in series increase backup?

Adding batteries adds energy whether wired in series or parallel, but your inverter must match the system voltage.

What went wrong?