An insertion loss calculator finds how much signal is lost when a device such as a filter, attenuator, connector or cable is placed between a source and a load. Enter the power or the voltage that reaches the load before and after the device is put in, and read the loss in decibels.
How to use the insertion loss calculator
- Choose power or voltage.
- Enter the level before insertion and the level after insertion, in the same unit.
- Press Calculate.
What insertion loss means
Wikipedia defines insertion loss as the loss of signal power that results from inserting a device in a transmission line or optical fibre, usually given in decibels [1]. It can come from intrinsic loss in the device, from a mismatch, or from both [1].
The power formula
With the power before insertion and the power after it, the insertion loss is IL = 10 log₁₀(P before ÷ P after), with the power sent to the load before insertion and the power received after it [1]. The result is in decibels, so the unit of the power does not matter as long as both values use the same one.
The voltage formula
With voltages, IL = 20 log₁₀(V before ÷ V after), comparing the signal level without and with the device in the line [1]. The factor 20 appears because power goes with the square of the voltage. That holds when the impedance is the same before and after, an assumption this tool makes.
A worked example
Take 12 watts before insertion and 4 watts after. The ratio is 3, and 10 log₁₀(3) is about 4.77 decibels, which the calculator shows as 4.771. In a second case, if 90 percent of the power gets through, the ratio is 100 ÷ 90 and the loss is about 0.46 decibels. Enter 100 and 90 to check.
Reading the decibel value
A loss of 3 decibels means that about half of the power is left, and 10 decibels means a tenth. Our own check: 10 log₁₀(2) is 3.01, so halving the power gives 3.01 decibels, and the voltage halves for 6.02 decibels. The calculator also shows what percentage of the power or voltage still reaches the load, which is easier to picture than a decibel figure.
Why a loss arises
Typical causes are ohmic loss in conductors, poor connections and dielectric loss in cable insulation. A device can also reflect part of the signal back to the source because of a mismatch [1]. The calculator does not tell the causes apart. It gives the total loss that you measured, from whatever mix of reflection and absorption.
Frequency
In general, the loss of a cable or filter changes with frequency. A value measured at one frequency therefore does not hold at another. When you compare cables, filters or connectors, use measurements made at the same frequency, and note it next to the result.
Negative results
If the level after insertion is higher than the level before, the result is negative. That is a gain, which an amplifier can give, and it is more likely to mean that you have swapped the two values. The calculator adds a note when this happens. Check which reading was taken with the device in the line and which without it.
Measurement setup
Insertion loss depends on how you measure it. Use the same source and load for both measurements, so that the match between them is the same. Compare like with like: first measure the load with the device out of the line, then with the device in, with nothing else changed. Then enter the two readings.
Using the calculator
Pick power or voltage, enter the two values, and press Calculate. The working line shows which formula was used with your numbers. Use the same units for both values, whether watts, milliwatts or volts. If you have values in decibels already, the loss is just the difference between the two levels, so you do not need this calculator.
Adding losses in a chain
Decibel losses of devices in series can be added, since each one multiplies the power by a fixed ratio and the logarithm turns products into sums. A cable of 1.5 decibels followed by a connector of 0.5 decibels and a filter of 3 decibels gives 5 decibels in total. This property of logarithms is our own working, and it holds when each device is measured with the same source and load impedance that it will see in use.
Insertion loss and return loss
Insertion loss is not the same as return loss, which measures how much of the signal is reflected back towards the source. A device can reflect little and still absorb a lot, or the reverse. The calculator gives only the net loss between the source and the load that you measured, and says nothing about which part is reflected.
Common mistakes
- Swapping the before and after values. A negative result is a warning.
- Using the 10 log formula for voltages. Voltages need 20 log.
- Mixing units such as watts and milliwatts. Use one unit.
- Comparing readings made at different frequencies. Loss changes with frequency.
What next
Use this often? Add Insertion Lo to your Home screen.
Frequently asked questions
What is an insertion loss calculator?
A tool that finds the loss in decibels caused by inserting a device in a signal path.
What is the insertion loss formula for power?
IL = 10 log₁₀(P before ÷ P after).
What is the formula for voltage?
IL = 20 log₁₀(V before ÷ V after), for the same impedance.
Why does insertion loss change with frequency?
For a given cable, the loss rises with frequency, so compare readings at one frequency.
What does a negative insertion loss mean?
The level went up, which is a gain, or the two readings were swapped.
Sources
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.