The ideal transformer calculator solves the turns, voltage and current relations of a lossless transformer. Enter a full pair of values, such as the turns of both windings, and any other known value, and it finds the secondary voltage, the currents and the power. It tells you whether the transformer steps the voltage up or down.
How to use the ideal transformer calculator
- Enter one full pair: both turns, both voltages or both currents.
- Add any other known value, for example the primary voltage or the primary current.
- Press Calculate.
- Read the turns ratio, all the values and the power check.
What an ideal transformer is
An ideal transformer is linear, lossless and perfectly coupled, according to the Wikipedia article [1]. Perfect coupling means that all the magnetic flux of the primary winding passes through the secondary winding, and no power is lost in the core or the wire. Real transformers come close, with efficiencies of the order of ninety-five per cent or better for large units, a figure of our own that the cited pages do not state.
The voltage and turns formula
The voltage across each winding is proportional to its number of turns: Vp ÷ Vs = Np ÷ Ns, which is the turns ratio [1]. Rearranged, the secondary voltage is Vs = Vp × Ns ÷ Np. More turns on the secondary mean a higher secondary voltage. The calculator uses Np ÷ Ns as the turns ratio, with the primary being the winding connected to the source.
The current formula
Power is conserved, so the current goes the opposite way: Is = Ip × Np ÷ Ns [1]. A step-up transformer raises the voltage and lowers the current in the same proportion. The Wikipedia article gives the current ratio as Is ÷ Ip = Np ÷ Ns [1]. This is why long power lines run at high voltage, where the same power needs less current and loses less in the wires.
Power in and power out
For an ideal transformer, the power on the primary, Vp × Ip, equals the power on the secondary, Vs × Is [1][2]. The calculator shows both figures when it knows a voltage and a current, so you can check that they agree. In a real transformer, the secondary power is always a little less than the primary power, since part of it is lost as heat.
A worked example
Take a primary of 100 turns and a secondary of 200 turns, with 110 volts and 2 amps on the primary. The secondary voltage is 110 × 200 ÷ 100 = 220 volts, and the secondary current is 2 × 100 ÷ 200 = 1 amp. The power is 220 watts on both sides. The turns ratio Np ÷ Ns is 0.5, so this is a step-up transformer.
Step-up, step-down and isolation
When Np is larger than Ns the voltage is stepped down and the current rises, as in a charger. When Np is smaller than Ns the voltage is stepped up. With equal turns the ratio is 1 : 1, which only isolates the circuits. A current transformer has far more secondary than primary turns, so its secondary current is much smaller, which follows from the current formula above.
Which values to enter
You can start from any full pair. If you know both voltages, the calculator finds the ratio, and if you then enter the primary turns, it finds the secondary turns. If you enter more values than are needed, it checks that they fit; when they differ by more than a tenth of a per cent, it reports a mismatch instead of picking one. This stops contradictory data from giving a misleading answer.
Notation
This tool uses Np and Vp for the primary winding, the one connected to the source, and Ns and Vs for the secondary, as in the Wikipedia article [1]. Check which winding a source calls the primary before you compare its formulas with these.
AC only
A transformer works only with a changing current, since it relies on a changing magnetic flux to induce a voltage in the other winding [1]. HyperPhysics describes transformers as raising or lowering AC voltages [2]. A steady direct current produces a steady field, which induces no voltage in the secondary. The calculator therefore uses RMS values of an AC source. Do not apply the results to a DC supply, and do not connect a mains transformer to the wrong supply.
Safety and real transformers
Mains voltages can kill, and a real transformer has limits, such as a rated power in volt-amperes, a maximum temperature and a fuse requirement. This calculator does not size a transformer: it gives the ideal ratios only. Choose and install real equipment with a qualified electrician, and follow the manufacturer's data sheet.
Where transformers are used
Transformers sit in phone chargers, power supplies, doorbells and the grid. A charger steps the mains down to a low voltage, while a power station steps the voltage up for transmission and a street transformer steps it down again. In each case the turns ratio sets the change in voltage and the current moves the other way. Enter the ratio of your device to see the figures, but remember that the label on the real unit gives its true rating.
Common mistakes
- Swapping the primary and the secondary. The primary is the winding connected to the source.
- Mixing peak and RMS values. Enter all the voltages and currents in the same form, usually RMS.
- Expecting the output to exceed the input power. An ideal transformer only transforms the voltage and current.
- Using it for DC. A transformer needs alternating current.
What next
Use this often? Add Ideal Transf to your Home screen.
Frequently asked questions
What is an ideal transformer calculator?
A tool that solves the turns, voltage and current relations of a lossless transformer.
What is the ideal transformer formula?
Vp ÷ Vs = Np ÷ Ns and Ip ÷ Is = Ns ÷ Np, so that the power in equals the power out.
How do I find the secondary voltage?
Multiply the primary voltage by Ns ÷ Np.
Why is the current lower on a step-up transformer?
Power is conserved, so a higher voltage means a lower current.
Does a real transformer follow these formulas?
Only approximately. Real transformers lose some power as heat, so the secondary power is a little lower.