Saved

Press the star next to a tool's name to save it.

All my tools

Door Header Size Calculator

Use this door header size calculator to find the header size and jack studs for a door or window opening in an exterior bearing wall, from IRC Table R602.7(1).

Restored your last values ·

For exterior bearing walls. Building width is measured perpendicular to the ridge, up to 36 ft. Spans are for No. 2 Douglas fir-larch, hem-fir, Southern pine or spruce-pine-fir.

Everything is worked out in your browser. Nothing you type is sent anywhere.

Smallest header that spans the opening

–

Choose what the header supports and enter the opening, then press Calculate.

See full result

This door header size calculator finds the smallest wood header that can span a door or window opening in an exterior bearing wall, using the header span table in the 2021 International Residential Code (IRC). Choose what the header supports, the ground snow load and the building width, enter the opening width, and the door header size calculator lists the header sizes that work and the number of jack studs each one needs at each end.

How to use the door header size calculator

  1. Choose what the header supports: just the roof and ceiling, or floors above as well.
  2. Choose the ground snow load for your area.
  3. Enter the building width, measured perpendicular to the ridge.
  4. Enter the opening width in feet and inches, and untick the bracing box if cripple studs will sit on the header. Then press Calculate.

What is a header?

A header is the beam over a door or window opening in a load-bearing wall. It carries the weight from above (the roof, ceiling and any floors) across the opening and down into jack studs, the shorter studs at each side of the opening that support the header's ends. Headers are usually made of two or more pieces of dimension lumber nailed together, such as two 2 × 8s, which the IRC writes as 2-2 × 8.

The IRC header span table

IRC Table R602.7(1) gives the maximum spans for girders and headers in exterior bearing walls. It covers headers made from one to four pieces of 2 × 4 to 2 × 12 lumber, and five loading cases: roof and ceiling only; roof, ceiling and one center-bearing floor; roof, ceiling and one clear-span floor; and the same with two floors. Each case has columns for ground snow loads of 30, 50 and 70 pounds per square foot and building widths of 12, 24 and 36 feet. For each, the table gives the maximum span and NJ, the number of jack studs needed at each end.

Table notes the calculator applies

  • Spans are based on No. 2 grade Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir lumber.
  • Building width is measured perpendicular to the ridge, and spans may be interpolated for widths between those shown. The calculator interpolates the span and uses the larger jack stud count of the two widths.
  • Use the 30 psf column where the ground snow load is less than 30 psf and the roof live load is 20 psf or less.
  • Where the top of the header isn't laterally braced, for example where cripple studs bear on it, the spans of 2 × 8, 2 × 10 and 2 × 12 headers must be multiplied by 0.70, or the header designed.
  • Where only one jack stud is needed, the header may instead be supported by an approved framing anchor attached to the full-height stud.

Worked example

Take a 6-foot door opening in the exterior wall of a house 24 feet wide, carrying only the roof and ceiling, with a ground snow load of 30 psf. A 2-2 × 8 header spans only 5 ft 9 in in this case, so it's too short. The calculator suggests a 3-2 × 8 header, which spans up to 7 ft 3 in with one jack stud at each end; a 2-2 × 10 also works, spanning up to 6 ft 10 in with two jack studs at each end.

For a building 18 feet wide, between the 12- and 24-foot columns, a 2-2 × 8 header in the same case spans 7 ft 7 in at 12 feet and 5 ft 9 in at 24 feet, so the interpolated span is 6 ft 8 in.

Reading the results

The big line is the smallest header size, in the order of the amount of lumber, that spans your opening. Below it is its maximum span and the jack studs it needs at each end. The table lists the other sizes that also work, so you can pick one that suits the wall depth or lumber you have.

How load and snow change the header

More load means a bigger header for the same opening. In the roof-and-ceiling case for a 24-foot-wide house, a 2-2 × 10 header spans 6 ft 10 in at 30 psf of ground snow, 5 ft 11 in at 50 psf and 5 ft 3 in at 70 psf. Adding floors above shortens the spans further, and wider buildings put more load on each foot of wall, so the same header spans less in a 36-foot-wide house than in a 12-foot one.

When the calculator finds no header

Some combinations of large openings and heavy loads exceed every size in the table. When that happens, the calculator says so instead of suggesting a size. A header for that opening needs to be designed, for example using engineered lumber sized by the manufacturer or an engineer, rather than taken from the prescriptive table.

Common mistakes

  • Using the house length. Building width is measured perpendicular to the ridge.
  • Ignoring floors above. Choose the load case that matches what the wall carries.
  • Forgetting cripples. Untick bracing if cripple studs sit on the header.
  • Using it for interior walls. Interior bearing walls use a different table.

Tips

  • Check your local snow load with your building department.
  • Set jack studs under both ends as the table requires.
  • Get engineered headers for larger openings or heavy point loads.

What next

Use this often? Add Door Header to your Home screen.

Frequently asked questions

How does a door header size calculator work?

It looks up IRC Table R602.7(1) for your load case, snow load and building width, and lists the headers whose maximum span covers your opening.

What size header for a 6-foot door?

For a 24-foot-wide house carrying only the roof at 30 psf snow load, a 3-2 × 8 (7 ft 3 in) or 2-2 × 10 (6 ft 10 in) header works.

How many jack studs does a header need?

The IRC table gives the number (NJ) for each header and case, usually one to three at each end.

How is building width measured?

Perpendicular to the ridge, according to the IRC table's footnote.

What if cripple studs sit on the header?

The spans of 2 × 8, 2 × 10 and 2 × 12 headers must be multiplied by 0.70, or the header designed.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Everyday Life Tools