Saved

Press the star next to a tool's name to save it.

All my tools

Curie's Law Calculator

Use this Curie's law calculator to find the susceptibility of a paramagnet from its Curie constant and temperature, use the Curie–Weiss law, and find the constant from the atoms.

Restored your last values ·

Choose Curie's law, the Curie–Weiss law, or the calculation of the Curie constant from the number of magnetic atoms, their g-factor and J. Enter the values and press Calculate.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Choose what you want and fill in the boxes, then press Calculate.

See full result

A Curie's law calculator finds the magnetic susceptibility of a paramagnetic material from its Curie constant and its temperature. It also applies the Curie–Weiss law above a Curie temperature, finds the magnetization in a given field, and works out the Curie constant from the number of magnetic atoms, their g-factor and J.

How to use the Curie's law calculator

  1. Choose what you want.
  2. Enter the Curie constant and the temperature, or the atom data.
  3. Press Calculate.

Curie's law

Curie's law says that the magnetic susceptibility of a paramagnetic material is χ = C ÷ T, where C is a material-specific Curie constant and T the absolute temperature [1]. The magnetization is M = χ H [1]. Pierre Curie found the law by experiment, and Langevin gave the classical explanation [1]. The susceptibility falls as the temperature rises, since heat disorders the magnetic moments.

Where it holds

The law holds only at high temperatures and weak fields [1]. At low temperatures, or in strong fields, the magnetization saturates and does not follow it. The page also warns not to confuse it with the Curie–Weiss law [1]. The calculator applies the simple law in its first mode, so use it for paramagnets that are not near a magnetic transition.

The Curie constant

For a simple two-state system of moments μ, the page gives C = μ₀ n μ² ÷ k_B, with n the number of moments per unit volume [1]. For atoms of total angular momentum J and a g-factor g, it gives C = μ₀ μ_B² g² n J(J + 1) ÷ (3 k_B) [1]. We take μ₀ = 4π × 10⁻⁷ and the Bohr magneton μ_B = 9.274 × 10⁻²⁴ J/T from our own knowledge.

A worked example

For 10²⁸ atoms per cubic metre with g = 2 and J = 1/2, the calculator gives C = 0.078282 kelvin. At 300 kelvin the susceptibility is 2.6094 × 10⁻⁴, and in a field of 1,000 amperes per metre the magnetization is 0.26094 amperes per metre. At 150 kelvin the susceptibility doubles. The numbers are our own example.

The Curie–Weiss law

For a ferromagnet in its paramagnetic region above the Curie temperature, the susceptibility follows χ = C ÷ (T − T_C), where both temperatures are in kelvin [2]. The law predicts a singularity at T = T_C, and below it the material has a spontaneous magnetization [2]. With C = 0.078282, T_C = 100 and T = 300, χ = 3.9141 × 10⁻⁴, 50 percent higher than for T_C = 0.

The Curie temperature

The Curie temperature is the threshold below which a material is ferromagnetic, and above which it is paramagnetic [2]. Each material has its own value. The page lists iron, nickel and magnetite as ferromagnets [2] but gives no Curie temperatures, so look up the value that you need. The calculator requires the temperature to be above T_C in the Curie–Weiss mode.

The Weiss constant

The page gives T_C = C λ μ₀, where λ is the Weiss molecular field constant [2]. It adds that the Curie–Weiss law is a mean-field theory, which fails near T_C, where the susceptibility behaves as 1 ÷ (T − T_C) raised to a critical exponent, and that far above T_C the law holds with a Weiss constant that is somewhat higher than the actual Curie temperature [2].

Units

The susceptibility here is the dimensionless volume susceptibility in the SI system. The Curie constant is therefore in kelvin, the number of atoms in inverse cubic metres, and the field in amperes per metre. In the Gaussian system, the numbers differ by factors of 4π and the constants differ. Use the SI figures in this calculator, and convert if your data is in another system.

Limits

The law gives good results for dilute paramagnets such as salts of rare earths at moderate temperatures. Metals have other contributions to their susceptibility. The calculator does not consider the orbital and spin coupling in detail beyond the g-factor and J that you enter. For a material that you do not know the g-factor of, use the first mode with a measured Curie constant.

Using the calculator

Select the mode. Enter the Curie constant and the temperature to get the susceptibility, and a field to get the magnetization. To find the Curie constant from the atoms, enter the number density, g and J. Compare susceptibilities at two temperatures to check that they scale as 1 ÷ T, which is a simple test of Curie behaviour.

Testing for Curie behaviour

A paramagnet that obeys Curie's law gives a straight line when the inverse susceptibility, 1 ÷ χ, is plotted against the temperature. The line passes through the origin, and its slope is 1 ÷ C. A line that cuts the temperature axis at a positive value instead shows Curie–Weiss behaviour, with the intercept at the Curie temperature. Use the calculator at several temperatures to build such a plot by hand. In the example, 1 ÷ χ is 3,832 at 300 kelvin and 1,916 at 150 kelvin.

Common mistakes

  • Using Celsius. Temperatures must be in kelvin.
  • Applying it near the Curie temperature. It fails there.
  • Mixing the SI and Gaussian systems. Check the constants.
  • Using it for a ferromagnet below T_C. The material is magnetized.

What next

Use this often? Add Curie's Law to your Home screen.

Frequently asked questions

What is a Curie's law calculator?

A tool that finds the susceptibility of a paramagnet from its Curie constant and temperature.

What is Curie's law?

χ = C ÷ T.

What is the Curie–Weiss law?

χ = C ÷ (T − T_C), for a ferromagnet above its Curie temperature.

When does Curie's law hold?

At high temperatures and weak fields.

What is the Curie constant for atoms?

C = μ₀ μ_B² g² n J(J+1) ÷ (3 k_B).

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Physics & Science Tools