A Boltzmann factor calculator finds how likely a system in thermal equilibrium is to be in a state of higher energy. Enter the energy difference between two states and the temperature, and it gives the Boltzmann factor and the ratio of the populations of the two states. Add the degeneracies for states with more than one level.
How to use the Boltzmann factor calculator
- Enter the energy difference and choose its unit.
- Enter the temperature.
- Add the degeneracies if they are not 1.
- Press Calculate.
The Boltzmann factor
In thermal equilibrium, the probability of a state of energy ε is proportional to exp(−ε ÷ k_B T), where k_B is the Boltzmann constant and T the absolute temperature [1]. This exponential is the Boltzmann factor. The higher the energy, or the lower the temperature, the smaller the factor and the less likely the state.
The constant
The Boltzmann constant is 1.380649 × 10⁻²³ joules per kelvin, and also 8.617333262 × 10⁻⁵ electronvolts per kelvin [2]. Since the 2019 redefinition of the SI units its value is exact [2]. The calculator works in electronvolts, and converts joules and kilojoules per mole to that unit. The conversion factors for those units are our own.
Thermal energy
The product k_B T is the scale of thermal energy. At 300 kelvin it is 0.025852 electronvolts. The page gives the thermal voltage at 300 kelvin as 25.85 millivolts [2], which is the same number expressed as a voltage. A state is easily reached when its energy above the ground state is about k_B T or less, and rarely when it is much more.
The ratio of two states
The ratio of the probabilities of two states depends only on the difference of their energies [1]. The page also says that the ratio of the populations of energy levels must take their degeneracies into account [1]. So N₂ ÷ N₁ = (g₂ ÷ g₁) exp(−ΔE ÷ k_B T), a form that is our own statement, where g is the number of states in each level.
A worked example
For an energy difference of 0.01 electronvolts at 300 kelvin, ΔE ÷ k_B T is 0.3868, and the factor is 0.6792. The upper state is then 68 percent as populated as the lower one if both have a single level. In a two-level system, that means 40.4 percent of the particles are in the upper level. These are our own calculations.
Degeneracy
If the upper level has three states and the lower has one, the ratio is multiplied by 3: with the numbers above, N₂ ÷ N₁ is 2.04. The calculator takes the two degeneracies, and leaves them at 1 if you do not enter them. The degeneracy is the number of distinct states with the same energy, such as the orientations of a magnetic moment.
Chemistry
Chemists often have energies in kilojoules per mole. A barrier of 10 kilojoules per mole at 298 kelvin gives a factor of about 0.0177, which is the share of molecules that can cross it on a simple estimate. A barrier of 50 kilojoules per mole gives 1.7 × 10⁻⁹. These estimates are our own, and they leave out other factors that matter for a real reaction rate.
Temperature
The calculator accepts kelvin, degrees Celsius and degrees Fahrenheit and converts them to kelvin. A temperature at or below absolute zero is not allowed. The result changes fast with temperature: at 600 kelvin the factor for 0.01 electronvolts is 0.8241, much nearer to 1 than at 300 kelvin, since more thermal energy is available.
Limits
The Boltzmann distribution applies to a system in thermal equilibrium with many particles. It does not hold for a system that is driven away from equilibrium, such as a laser medium with a population inversion. Quantum effects at very low temperatures also change the result for particles such as electrons, which follow different statistics.
Using the calculator
Pick the unit of the energy and the temperature, enter the two values, and add degeneracies if you need them. Read the factor and the population ratio. Change the temperature to see how the upper state fills up as it gets hotter, and change the energy to see how quickly a bigger gap empties the upper state.
Large gaps
For a gap of 1 electronvolt, which is typical of electronic transitions, the factor at 300 kelvin is only 1.6 × 10⁻¹⁷, so practically no particles are excited by heat alone. At 1,000 kelvin it is 9.1 × 10⁻⁶. Compare this with a gap of 0.01 electronvolts, typical of rotations and small vibrations, which are excited at room temperature. These comparisons are our own calculations.
Reading the result
A factor close to 1 means that the energy gap is small compared with k_B T, so the two states are about equally populated apart from degeneracy. A factor close to 0 means that the upper state is almost empty. Between them, a factor of 0.37 corresponds to a gap of exactly k_B T. Use the line that gives the share in the upper level to see the result as a percentage of all the particles in a two-level system.
Common mistakes
- Using Celsius in the exponent. Use kelvin.
- Mixing J and eV. Check the unit.
- Forgetting degeneracy. It multiplies the ratio.
- Applying it away from equilibrium. It needs thermal equilibrium.
What next
Use this often? Add Boltzmann Fa to your Home screen.
Frequently asked questions
What is a Boltzmann factor calculator?
A tool that finds exp(−E ÷ kT) and the ratio of the populations of two energy states.
What is the Boltzmann factor?
exp(−ε ÷ k_B T), proportional to the probability of a state of energy ε.
What is the Boltzmann constant?
1.380649 × 10⁻²³ J/K, or 8.617333262 × 10⁻⁵ eV/K.
What is kT at 300 K?
About 0.02585 eV, which is a thermal voltage of 25.85 mV.
How do degeneracies enter?
The ratio is multiplied by g₂ ÷ g₁.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.