Saved

Press the star next to a tool's name to save it.

All my tools

SCFM Calculator

Use this SCFM calculator to convert an actual flow rate to standard cubic feet per minute, correcting for the gas temperature, the gauge pressure and the chosen standard conditions.

Restored your last values ·

Choose US or metric units and the standard conditions. Enter the actual flow rate, the gas temperature and the gauge pressure at the flow. Leave the atmospheric pressure blank to use the standard value.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the actual flow, the temperature and the gauge pressure, then press Calculate.

See full result

An SCFM calculator converts an actual flow of gas, in cubic feet per minute at the real temperature and pressure, into standard cubic feet per minute at a fixed reference state. This lets you compare compressors, blowers and gas flows on the same basis. Enter the actual flow, the temperature and the gauge pressure, and pick the standard conditions.

How to use the SCFM calculator

  1. Choose US or metric units and the standard conditions.
  2. Enter the actual flow, the temperature and the gauge pressure at the flow.
  3. Optionally enter the local atmospheric pressure.
  4. Press Calculate.

What SCFM means

A standard cubic foot is the amount of gas contained in one cubic foot at a reference temperature and pressure [1]. The flow in SCFM is therefore a measure of mass flow, and not a volume at the conditions of the line. Cubic feet per minute is a common unit for air delivery in pneumatic tools and air-compressor systems [2], and the standard version corrects that flow to the reference state. Two compressors can both deliver 100 actual cubic feet a minute, yet give very different SCFM if one runs at a higher pressure.

The conversion formula

Wikipedia gives the conversion as standard volume = actual volume × Fp × Ft × (Fpv)², where Fp is the pressure factor, the absolute line pressure divided by the standard pressure, and Ft is the temperature factor, the absolute standard temperature divided by the absolute line temperature [1]. Fpv is the supercompressibility factor, often omitted or set to 1 [1]. The calculator takes Fpv as 1.

The temperature and pressure factors

Written out with the temperature in °C and the gauge pressure in psig, the same correction is SCFM = ACFM × (294.26 ÷ (T + 273.15)) × ((14.696 + P) ÷ 14.696). This is our own rewriting of the two factors above: 294.26 K is 70 °F, and 14.696 psia is the standard pressure for US industrial gas [1]. Rounding the standard pressure to 14.7 changes the result only in the fourth digit.

Standard conditions

Definitions vary. Wikipedia lists 60 °F and 14.696 psia, with 14.70 or 14.73 as variants, for petroleum gases, and 70 °F and 14.696 psia for US industrial gas [1]. A standard cubic metre uses 15 °C and 101.325 kPa [1]. The calculator offers 70 °F, 60 °F and 15 °C, all at 101.325 kPa, which equals 14.696 psia. Many different definitions of standard reference conditions are in use around the world [3], so always check which one your supplier uses, because choosing the wrong one changes the answer by a few percent.

A worked example

Take 100 ACFM at 50 °C and 20 psig. In our tool, enter 100, 122 °F and 20 psig. The pressure factor is (20 + 14.696) ÷ 14.696 = 2.3609 and the temperature factor is 294.26 ÷ 323.15 = 0.9106, so the result is about 214.985 SCFM. Using 14.7 psia instead of 14.696 would give 214.95.

Open air and atmospheric pressure

At a gauge pressure of 0 and sea-level air, the pressure factor is 1 and only the temperature matters. For example, 200 ACFM at 25 °C and 0 psig gives about 197.4 SCFM. At altitude, you can enter the local atmospheric pressure in psia or kPa. The absolute pressure is the gauge pressure plus that value [1].

Metric flows

If you work in metric units, enter the flow in cubic metres a minute, the temperature in °C and the gauge pressure in kPa. The result is shown in standard cubic metres a minute, and also in SCFM using 1 cubic foot = 0.028316846592 cubic metres [2]. The metric mode follows the same formula, with the standard pressure 101.325 kPa.

Why humidity is not included

The formula assumes dry gas, and the tool has no humidity correction. Moist air carries less dry gas per cubic foot, so for wet compressed air the true dry SCFM is a little lower. We do not apply any correction, which is our stated limit. For compressor sizing and for pneumatic tool needs, the dry-gas figure is the normal convention.

What the pages do not say

The Wikipedia page on the standard cubic foot defines the standard volume and the conversion, but it does not define SCFM itself [1]. The tool treats the line pressure as absolute pressure, which is the gauge pressure plus the atmosphere. Gauge pressures below zero are allowed as long as the absolute pressure stays positive.

Using the calculator

Pick the units and the standard conditions your supplier or catalogue uses. Enter the actual flow, the temperature and the gauge pressure at the point where the flow was measured. The page shows the standard flow, the two correction factors and the working. Use it to compare air tools, regulators and compressors on a like-for-like basis, and to convert catalogue SCFM into the flow you will see at the real pressure.

Why compressors are rated in SCFM

A compressor squeezes gas into a smaller volume, so an actual flow at the delivery pressure holds far more gas than the same volume at atmospheric pressure. Quoting SCFM removes that ambiguity, because it states how much gas moves, not the space it fills. Air tools are also rated in SCFM at a given working pressure, so you can match the tool to the compressor by comparing the two figures directly.

Common mistakes

  • Using absolute and gauge pressure the wrong way round. Enter gauge pressure; the tool adds the atmosphere.
  • Mixing standard definitions. 60 °F and 70 °F give different results.
  • Entering the temperature in the wrong unit. US units use °F, metric units use °C.
  • Ignoring humidity. The tool gives a dry-gas flow.

What next

Use this often? Add SCFM to your Home screen.

Frequently asked questions

What is an SCFM calculator?

A tool that converts an actual flow rate at the real temperature and pressure into a standard flow rate at a fixed reference state.

What is the formula to convert ACFM to SCFM?

SCFM = ACFM × Fp × Ft, where Fp is the absolute pressure divided by the standard pressure and Ft is the standard temperature divided by the line temperature, both absolute.

What are the standard conditions for SCFM?

Common choices are 70 °F or 60 °F with 14.696 psia. Definitions vary, so check your supplier's reference.

What is the difference between CFM and SCFM?

CFM is the volume flow at the actual conditions. SCFM is that flow corrected to the reference state, so it measures the amount of gas.

Does SCFM include humidity?

No. The calculator assumes dry gas and applies no humidity correction.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.

More Unit Converters