Enter the coefficients and the size, then press Calculate.

See full result

A Biot number calculator finds the Biot number of a body that is heated or cooled by a fluid, from the convection coefficient at its surface, its thermal conductivity and its size. It tells you whether the temperature inside the body is nearly uniform, so that the simple lumped-capacitance model can be used.

How to use the Biot number calculator

  1. Choose US or metric units and the shape.
  2. Enter h, k and the size of the body.
  3. Press Calculate.

The definition

The Biot number is Bi = h L ÷ k, where k is the thermal conductivity of the body in watts per metre kelvin, h is the convective heat transfer coefficient in watts per square metre kelvin and L is a characteristic length in metres [1]. It compares the resistance to heat flow inside the body with the resistance at its surface. The page says that it should not be confused with the Nusselt number, which uses the conductivity of the fluid [1].

The characteristic length

The characteristic length is the ratio between the volume of the body and the surface through which the heat passes [1]. For a sphere, this is r ÷ 3, which is D ÷ 6. For a long cylinder, it is r ÷ 2, or D ÷ 4. For a plate heated on both faces, it is half the thickness, and for a cube it is the side divided by 6. These shape formulas are our own geometry.

The 0.1 rule

A Biot number below about 0.1 means that the conduction inside the body is much faster than the convection at the surface, so the body stays at nearly the same temperature throughout [1]. The page says that this generally gives less than 3 percent error when the lumped-capacitance model is used [1]. Such bodies are called thermally thin, and those above about 0.1 thermally thick [1].

A worked example

A steel sphere of 20 millimetres in air, with a convection coefficient of 25 watts per square metre kelvin and a conductivity of 50 watts per metre kelvin, has a characteristic length of 3.33 millimetres. The Biot number is 25 × 0.003333 ÷ 50, which is 0.00167. That is far below 0.1, so the lumped model works. These numbers are our own example.

A thick body

A plate of 20 millimetres, heated on both faces by a liquid with h of 500, with a conductivity of 1, has a characteristic length of 10 millimetres and a Biot number of 5. That is well above 0.1, so the temperature inside the plate is far from uniform, and a full conduction calculation is needed. The calculator tells you which case applies in the last line.

The lumped model

When the Biot number is small, the temperature of the body follows an exponential decay towards that of the fluid, with a time constant τ = ρ c_p V ÷ (h A) [1]. The page gives this relation, but the arrangement of its equation is garbled in the text that we could read, so use it as a reference only. The calculator does not compute the time constant. It checks whether the model is valid.

Units

In US mode, the convection coefficient is in Btu per hour per square foot per degree Fahrenheit, the conductivity is in Btu per hour per foot per degree Fahrenheit, and the size is in inches. The calculator converts them to SI using 5.678263 and 1.730735 as the conversion factors, which are our own. The Biot number is dimensionless, so it is the same in either system.

Typical values

Convection coefficients are small in still air, larger in moving air, and much larger in boiling or flowing water, while the conductivities of metals are far higher than those of plastics or food. This is why a small metal part cools evenly in air, while a large piece of meat in an oven has hot surfaces and a cool centre. The page gives no typical values, so check a handbook.

Limits

The Biot number depends on the heat transfer coefficient, which is itself an estimate that depends on the flow around the body. The result is therefore only as good as that value. For a body of an irregular shape, choose the shape that is closest, or compute the volume and the area of the body yourself and use the characteristic length formula.

Choosing a shape

Pick the shape that is closest to your body. A ball or a round fruit is a sphere, a rod or a wire is a long cylinder, a sheet or a wall heated on both sides is a plate, and a block is a cube. For a plate that is insulated on one face, the heat passes through only one face, so the characteristic length is the whole thickness and not half of it, which you can obtain by doubling the thickness that you enter. Use the working line to check the length that was used.

What to do for a high Biot number

If the number is high, the temperature differs between the surface and the centre during heating or cooling. Then use a full transient conduction analysis, with charts or a numerical method. The Biot number also tells you which resistance to improve: a high value means that the body itself resists heat flow, so a better convection coefficient will not help much.

Common mistakes

  • Using the full size as the length. Use V ÷ A.
  • Using the conductivity of the fluid. That gives the Nusselt number.
  • Mixing the units of h and k. Check the units setting.
  • Using the lumped model above 0.1. Use a full conduction analysis.

What next

Use this often? Add Biot Number to your Home screen.

Frequently asked questions

What is a Biot number calculator?

A tool that finds the ratio of surface convection to internal conduction for a body.

What is the Biot number formula?

Bi = h L ÷ k, with L = V ÷ A.

When can I use the lumped-capacitance model?

When Bi is below about 0.1.

Is the Biot number the same as the Nusselt number?

No. The Nusselt number uses the conductivity of the fluid.

What is the characteristic length of a sphere?

r ÷ 3, which is D ÷ 6.

What went wrong?