Saved

Press the star next to a tool's name to save it.

All my tools

Annealing Temperature Calculator

Use this annealing temperature calculator to find a starting PCR annealing temperature from the primer melting temperature, using the rule of 3 to 5 degrees below Tm.

Restored your last values ·

Enter the melting temperature (Tm) of one primer, or of both primers of a pair. The calculator gives an annealing temperature 3 to 5 °C below the lower Tm and checks it against the usual 50 to 65 °C range.

Everything is worked out in your browser. Nothing you type is sent anywhere.

–

–

Enter the Tm of your primer, then press Calculate.

See full result

A annealing temperature calculator gives a starting temperature for the annealing step of a PCR from the melting temperature (Tm) of your primers. Enter the Tm of one primer or of both primers in a pair, and it gives a range 3 to 5 °C below the lower Tm, then checks the answer against the usual range for the step.

How to use the annealing temperature calculator

  1. Enter the Tm of primer 1 in degrees Celsius, taken from your primer supplier or a design tool.
  2. Enter the Tm of primer 2 if you have a pair.
  3. Press Calculate to see the annealing range, its middle value and the difference between the primers.

The 3 to 5 degree rule

The Wikipedia article on the polymerase chain reaction says that a typical annealing temperature is about 3 to 5 °C below the Tm of the primers used.[1] It explains that the temperature must be low enough to allow hybridization of the primer to the strand, but high enough for the hybridization to be specific.[1] The calculator applies this rule to the lower of the two Tm values, since both primers must anneal. For a Tm of 60 °C it gives 55 to 57 °C, with 56 °C in the middle.

The usual range

The same page says that in the annealing step the reaction temperature is lowered to 50 to 65 °C for 20 to 40 seconds.[1] The calculator checks whether the middle value falls in this range and tells you when it does not. A result outside the range is a hint that the primers have an unusually low or high Tm, or that the Tm was entered in the wrong unit.

Primer pairs should have similar Tm

The article on primers says that pairs of primers are designed to have similar melting temperatures, and that the melting temperature should not be much higher or lower than the reaction's annealing temperature.[2] It also says primers are typically between 18 and 24 bases in length.[2] The page gives no numerical limit on the Tm difference, so the calculator simply shows the difference and leaves the judgement to you. A larger gap means the annealing temperature that suits one primer is poor for the other.

What affects the Tm

The article on nucleic acid thermodynamics says that the melting temperature depends on the length of the DNA molecule and on its specific nucleotide sequence.[3] It states that cytosine and guanine base pairing is generally stronger than adenine and thymine base pairing, and that higher temperatures are associated with high GC content.[3] It adds that several formulas are used to calculate Tm values and that some are more accurate than others, and that stacking stabilization varies with salt concentration and temperature.[3] For these reasons the same primer can have different Tm values from different calculators. We do not include a Tm formula in this tool, because the pages we read do not give a rule for primers that we could check, so enter the Tm from a source you trust.

Worked examples

For a primer pair with Tm 60 °C and 62 °C, the lower Tm is 60 °C, so the annealing temperature is 55 to 57 °C, and the two primers differ by 2 °C. For a pair with Tm 58 °C and 62 °C, the range is 53 to 55 °C and the gap is 4 °C. A single primer with Tm 52 °C gives a middle value of 48 °C, which is below the usual 50 to 65 °C range, so the calculator flags it. These are our own applications of the rule.

Optimizing in the lab

A calculated value is a place to start. If you see no product, try a lower temperature. If you see extra bands, try a higher one. Many thermal cyclers can run a gradient across several wells at once, which finds a good temperature in a single run. Changing the salt or magnesium concentration also changes the best temperature.

How the steps fit together

The PCR page lists the stages of each cycle: denaturation at 94 to 98 °C for 20 to 30 seconds, annealing at 50 to 65 °C for 20 to 40 seconds, and extension, commonly at 72 °C when Taq polymerase is used.{1} The annealing temperature is the only one of these three that depends on your primers, which is why it is worth calculating. Setting it too low allows the primers to bind to sequences that match only partly, which gives extra bands. Setting it too high stops the primers from binding well, which gives little or no product.

Using the Tm from a supplier

Primer suppliers print a Tm on the data sheet, and design tools show one when you choose a pair. These values depend on the model and the salt conditions the tool assumes, so check which conditions it states. If you take Tm values from two different tools for the two primers, the difference between them may be partly an artifact. Take both from the same source whenever you can.

Common mistakes

  • Using the higher Tm. Base the annealing temperature on the lower Tm of the pair.
  • Mixing Tm sources. Different calculators give different Tm values for the same primer.
  • Entering Fahrenheit. The calculator expects degrees Celsius.

What next

Use this often? Add Annealing Te to your Home screen.

Frequently asked questions

What is an annealing temperature calculator?

A tool that gives a starting annealing temperature for a PCR from the melting temperature of the primers, using the rule of 3 to 5 °C below the Tm.

How do I calculate the annealing temperature from Tm?

Subtract 3 to 5 °C from the lower Tm of the primer pair. For a lower Tm of 60 °C the range is 55 to 57 °C.

What is a typical annealing temperature range?

50 to 65 °C, held for about 20 to 40 seconds in the annealing step.

Should both primers have the same Tm?

They should be similar, so that one annealing temperature suits both.

Does this calculator work out Tm from the sequence?

No. Enter the Tm from your primer supplier or a design tool, because different formulas give different Tm values.

What went wrong?

We only receive the reason you pick, never what you typed into the tool.

Thanks for your feedback.