A watts to heat calculator converts a power in watts into the heat it gives off, as Btu per hour, kilocalories per hour and kilojoules per hour. Add a time to see the total heat over that period, which is useful for heaters, electronics and cooling loads.
How to use the watts to heat calculator
- Enter the power in watts.
- Optionally enter the time in hours.
- Press Calculate to read the heat rate and the total heat.
What a watt means
A watt is a rate of energy: one joule per second. A device that uses 1,000 watts for one hour transfers 3,600,000 joules, or 3,600 kilojoules, which is one kilowatt-hour. If all that energy turns into heat, the heat output is the same figure. This is our own working from the definition of the watt, and it is the base of every conversion on this page.
Watts to Btu per hour
The British thermal unit is used for heating and cooling equipment in the United States. The Wikipedia page for it says that 1 watt is approximately 3.412142 Btu per hour [1], which also follows from the International Table Btu of about 1,055.06 joules [1]. So Btu per hour is the watts times 3.412142. A 1,000 watt heater gives 3,412.14 Btu per hour.
Watts to kilocalories
The thermochemical calorie is exactly 4.184 joules, and a kilocalorie is 1,000 calories, so 4,184 joules [2]. One watt is 3,600 joules per hour, so it is 3,600 ÷ 4,184 = 0.86042 kilocalories per hour. A 1,000 watt source gives 860.421 kcal per hour. The Wikipedia page for the Btu gives its own kilocalorie value for a Btu, 0.2522 kcal [1], which agrees to the figures shown.
Kilojoules and kilowatt-hours
Kilojoules per hour are the watts times 3.6, because 1 watt is 3,600 joules per hour and 1 kilojoule is 1,000 joules. The calculator also shows the energy over your time in kilowatt-hours, the unit on an electricity bill. A 1,000 watt heater running for 2.5 hours uses 2.5 kWh, which is 9,000 kJ.
Worked example
Take a 1,000 watt electric heater running for 2.5 hours. The heat rate is 3,412.14 Btu per hour, 860.421 kcal per hour and 3,600 kJ per hour. Over 2.5 hours, the total heat is 8,530.35 Btu, 2,151.05 kcal and 9,000 kJ. The calculator prints exactly these lines, so you can use them to check a spreadsheet of your own.
When all the power becomes heat
For a resistive electric heater, almost every watt that goes in comes out as heat in the room. The same is true, in the end, of a computer, a television or a charger in a closed room: the electrical energy ends up as heat. That is why a server room needs cooling equal to the power drawn. This is our own working, not a figure from the pages we opened.
When it does not
A lamp turns part of its power into light, a motor into movement and a pump into water pressure. Even so, in a closed room, most of that energy also becomes heat in the end. A heat pump moves more heat than the electrical power it uses, so its heat output can be several times its watts. Use the efficiency of the equipment if you need the real heat delivered.
Heating and cooling sizes
Air conditioners and heaters are often rated in Btu per hour in the US. A rating of 12,000 Btu per hour is about 3,517 watts of heat. To check the heat that a device adds to a room, multiply its watts by 3.412142. Compare the result with the cooling capacity you have. The calculator gives the heat from the device, not the heat from the sun, people or the walls.
Using the calculator
Type the watts, add the hours if you wish, and press Calculate. Change the watts to see how the heat grows in direct proportion: double the power and the heat doubles. The figures are rounded to six significant digits. The numbers are the same whether the power is electric, mechanical or from a fuel, as long as it is given in watts.
Worked comparisons
A 100 watt incandescent bulb gives off about 341 Btu per hour if all its power ends up as heat in the room, and a 500 watt space heater gives about 1,706 Btu per hour. A laptop that draws 60 watts adds about 205 Btu per hour, which is about 52 kcal per hour. Add up the watts of all the devices in a small room to see their combined heat, then compare the total with the cooling capacity you have. The sums are simple multiplications, so you can repeat them by hand.
These figures are our own arithmetic with the factor of 3.412142 from the Wikipedia Btu page, and they assume all the power becomes heat.
Heat and energy bills
The total over a time is the same energy that your electricity meter counts. A 1,000 watt heater that runs for 10 hours uses 10 kilowatt-hours and gives off 34,121 Btu. Multiply the kilowatt-hours by your own tariff to see the cost of that heat. The calculator shows the kilowatt-hours next to the heat so that you can do exactly that.
Common mistakes
- Confusing Btu with Btu per hour. A Btu is energy and Btu per hour is a rate.
- Treating a heat pump as 100 percent efficient. It can deliver more heat than it uses.
- Forgetting the time. A rate in watts needs hours to give a total.
- Using kilowatts as watts. Multiply kilowatts by 1,000 first.
What next
Use this often? Add Watts to Hea to your Home screen.
Frequently asked questions
How does a watts to heat calculator work?
It multiplies the watts by 3.412142 for Btu per hour, by 3,600 and divides by 4,184 for kcal per hour, and by 3.6 for kJ per hour.
How many Btu per hour is 1 watt?
About 3.412142 Btu per hour.
Does all the power become heat?
For a resistive heater, almost all of it does. A heat pump can deliver more heat than its electrical power.
How do I get the heat over a time?
Enter the hours. The calculator multiplies each heat rate by the time.
What is a kilocalorie in joules?
4,184 joules, using the thermochemical calorie of 4.184 joules.
Was this tool helpful?
What went wrong?
We only receive the reason you pick, never what you typed into the tool.
Thanks for your feedback.